Technical data............ 44 Switching on the product ........15 Index ................... 48 Filling and purging the heating installation ..16 Filling the condensate siphon ......16 Filling the hot water circuit ........16 Installation and maintenance instructions ecoFIT pure 0020230533_01...
▶ Do not use any electrical switches, mains plugs, doorbells, telephones or other com- munication systems in the building. ▶ If it is safe to do so, close the emergency control valve or the main isolator. 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Page 4
(electrical partition with a contact opening ▶ If you are installing the product in of at least 3 mm, e.g. fuse or line protec- hairdressing salons, painter's or joiner's tion switch). workshops, cleaning businesses or similar Installation and maintenance instructions ecoFIT pure 0020230533_01...
1.4.13 Risk of material damage caused by using an unsuitable tool ▶ Use the correct tool to tighten or loosen screw connections. Regulations (directives, laws, standards) ▶ Observe the national regulations, stand- ards, guidelines and laws. 0020230533_01 ecoFIT pure Installation and maintenance instructions...
For quality control purposes; 5th and 6th Benchmark digits = week of production For identification purposes; 7th to 16th Vaillant is a licensed member of the Benchmark Scheme. digits = product article number Benchmark places responsibilities on both manufacturers For quality control purposes; 17th to 20th and installers.
Gas connection Connection on the top Heating return of the air/flue pipe Check whether the wall has sufficient load-bearing ca- pacity to bear the operational weight of the product. Installation and maintenance instructions ecoFIT pure 0020230533_01...
(1), one from the top and one from the bottom. Lift the front casing upwards from the bracket. Tilt the side section to the outside and move it down- wards and out. 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Purge the gas line before start-up. Check whether the connections (→ Page 18) are leak- tight. Caution. Risk of material damage due to heat trans- fer during soldering. Installation and maintenance instructions ecoFIT pure 0020230533_01...
During installation remove all burs from inside of cut pipe work and avoid excessive adhesive which may trap small pockets of water close to the pipe wall which can freeze and build into a larger ice plug. 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Page 12
24 V controller Outside temperature switches). sensor, wired Provide one common electricity supply for the boiler Open the electronics box. (→ Page 11) and for the corresponding controller: Carry out the wiring. (→ Page 12) Installation and maintenance instructions ecoFIT pure 0020230533_01...
Status codes – Overview (→ Page 31) tions. An overview of the display and setting options in the installer level can be found in the section "Overview of the installer level". (→ Page 13) 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Before filling the system, measure the hardness of the filling and supplementary water. Treating the filling and supplementary water ▶ Observe all applicable national regulations and technical standards when treating the filling and supplementary water. Installation and maintenance instructions ecoFIT pure 0020230533_01...
▶ When using additives, follow the manufacturer's instruc- tions without exception. We accept no liability for the compatibility of any additive or its effectiveness in the rest of the heating system. 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Ensure that all other gas appliances in the property are turned off. ▶ Measure the gas flow rate at the gas meter. ▶ Compare the measured values with the corresponding values in the table. Installation and maintenance instructions ecoFIT pure 0020230533_01...
With the boiler operating at full load check that the gas inlet working pressure at the reference test point (2) complies with the requirements. 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Wait until the value that is read is stable. installation – Waiting period for reading a stable value: 5 min You can reset/change the system parameters. Overview of diagnostics codes (→ Page 28) Installation and maintenance instructions ecoFIT pure 0020230533_01...
Flow rate [l/h] ▶ Ensure that the operator is familiar with all of the Anti-legionella measures in order to comply with the applicable regulations regarding legionella prevention. ▶ Set the hot water temperature. Installation and maintenance instructions ecoFIT pure 0020230533_01...
▶ To delete the entire fault list, navigate to diagnostics code D.094 in the installer level. ▶ Set the diagnostics code to 1, and confirm by pressing Remove the gas pipe (1). 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Page 22
Connect the pump cable to the electronics box. 10.5.5 Replacing the expansion vessel Drain the product. (→ Page 27) 11. Remove the clip underneath the condensate tray (1). 12. Undo the four screws (2). Installation and maintenance instructions ecoFIT pure 0020230533_01...
Page 23
Install the new PCB in such a way that it clicks into the groove at the bottom and into the clip at the top. Plug in the PCB plugs. Close the electronics box. 0020230533_01 ecoFIT pure Installation and maintenance instructions...
To increase the CO₂ content: Turn anti-clockwise ◁ To decrease the CO₂ content: Turn clockwise ▶ Only carry out the adjustment in increments of 1/8 turn and wait approximately 1 minute after each adjustment until the value has stabilised. Installation and maintenance instructions ecoFIT pure 0020230533_01...
Close the gas isolator cock. Remove the front casing. (→ Page 9) Remove the air intake pipe (3). Remove the plugs from the gas valve (4) and from the fan (5). Remove the gas-air mixture unit (6). 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Disconnect the connection (2) and the earthing cable (1). Remove the fixing screws (3). Carefully remove the electrode from the combustion chamber. Check that the electrode ends (4) are undamaged. Check the electrode distance. Installation and maintenance instructions ecoFIT pure 0020230533_01...
Drain the product. (→ Page 27) 13 Customer service To ensure regular servicing, it is strongly recommended that arrangements are made for a Maintenance Agreement. Please contact Vaillant Service Solutions for further details: Telephone: 0330 100 3461 0020230533_01 ecoFIT pure Installation and maintenance instructions...
= Flow temperature Adjustable on = Return temperature (ad- justment for underfloor heating. If you have activated the return temperature control, the auto- matic heating output determina- tion function is not active.) Installation and maintenance instructions ecoFIT pure 0020230533_01...
Page 29
– d.33 Fan speed target value Current value Fan speed = Display value x 100 adjustable – d.34 Value for the fan speed Current value Fan speed = Display value x 100 adjustable 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Page 30
"Technical data" K d.73 Correction of the hot wa- Adjustable ter warm start temperat- d.75 Maximum cylinder re- Adjustable heating time – – – d.77 Max. cylinder reheating Adjustable → Section "Technical data" Installation and maintenance instructions ecoFIT pure 0020230533_01...
Displays in hot water handling mode S.10 Hot water handling mode: Requirement S.11 Hot water handling mode: Advance fan operation S.13 Hot water handling mode: Burner ignition S.14 DHW mode: Burner on S.15 DHW mode: Pump/fan overrun 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Short circuit: Cylinder temperature NTC sensor defective, short circuit in the cable harness, cable/casing F.91 sensor F.13 Short circuit: Domestic hot water cylinder NTC sensor defective, short circuit in the cable harness, cable/casing temperature sensor Installation and maintenance instructions ecoFIT pure 0020230533_01...
Page 33
When the burner starts, the temperature change registered at the flow or return temperature sensor is non-existent or too small: Insufficient water in the product, the flow or return temperature sensor is not in the correct position on the pipe 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Page 34
F.89 Fault: Pump Pump not connected or it is connected incorrectly, incorrect pump connec- ted, short circuit in the cable harness Connection No communication between the PCB Electronics defective and the user interface Installation and maintenance instructions ecoFIT pure 0020230533_01...
230Vac Main PCB Pressure sensor Interface PCB External ignition device Temperature sensor in the heating flow Heating pump Temperature sensor in the heating return Ionisation and ignition electrode Main power supply Gas valve 0020230533_01 ecoFIT pure Installation and maintenance instructions...
RT 230Vac 230Vac Main PCB Gas valve Interface PCB Pressure sensor Control system Ionisation electrode Temperature sensor in the heating flow Heating pump Temperature sensor in the heating return Ignition electrode Main power supply Installation and maintenance instructions ecoFIT pure 0020230533_01...
Check the product for gas, flue gas, water and condensate leaks, and repair if necessary. Record the inspection/maintenance work carried out. *Note: For those appliances which are not part of an annual service agreement/policy, maintenance must be carried out at least every 5 years. 0020230533_01 ecoFIT pure Installation and maintenance instructions...
300 mm Horizontal from adjacent windows on pitched or flat roofs 600 mm Above adjacent windows on pitched or flat roofs 600 mm Below adjacent windows on pitched or flat roofs 2,000 mm Installation and maintenance instructions ecoFIT pure 0020230533_01...
300 mm is preferred. For 1 and 2 above you can use a flue gas management kit to enable the termination point to be positioned and directed away from the building fabric. 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Page 41
Optimum start control Fitted Fitted Fitted Fitted ALL SYSTEMS CENTRAL HEATING MODE mbar mbar COMBINATION BOILERS ONLY DOMESTIC HOT WATER MODE mbar OR mbar Temperature CONDENSING BOILERS ONLY ALL INSTALLATIONS Ratio ² Ratio ² 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Page 42
SERVICE 06 ² % ² % ² % ² % SERVICE 07 SERVICE 08 ² % ² % ² % ² % SERVICE 09 SERVICE 10 ² % ² % ² % ² % Installation and maintenance instructions ecoFIT pure 0020230533_01...
Page 43
Ensure test points are capped, boiler case is correctly replaced and all other commissioning procedures are completed. Complete Benchmark Checklist, recording CO and combustion ratio readings as required. 0020230533_01 ecoFIT pure Installation and maintenance instructions...
40/30 °C Effective output range (P) 7.5 … 31.8 kW at 50/30 °C Effective output range (P) 7.2 … 30.5 kW at 80/60 °C Domestic hot water heat 7.1 … 35.0 kW output (P) Installation and maintenance instructions ecoFIT pure 0020230533_01...
Page 45
Product dimensions, height 700 mm 700 mm 700 mm 700 mm Net weight 31 kg 31 kg 31 kg 32 kg Weight when filled with water 35 kg 35 kg 35 kg 36 kg 0020230533_01 ecoFIT pure Installation and maintenance instructions...
Page 46
T2/2A, 250V T2/2A, 250V T2/2A, 250V T2/2A, 250V Max. electrical power consump- 75 W 81 W 87 W 87 W tion Standby electrical power con- sumption Level of protection IPX4D IPX4D IPX4D IPX4D Installation and maintenance instructions ecoFIT pure 0020230533_01...
Page 47
Appendix VU 306/6-3 (H-GB) Electric connection 230 V / 50 Hz Built-in fuse (slow-blow) T2/2A, 250V Max. electrical power consump- 104 W tion Standby electrical power con- sumption Level of protection IPX4D 0020230533_01 ecoFIT pure Installation and maintenance instructions...