Optimanufacturing T60-1001-C8-1A Operation & Service Manual

Optimanufacturing T60-1001-C8-1A Operation & Service Manual

T60 series cable tensiometer

Advertisement

OPERATION & SERVICE MANUAL FOR
SOP-TN-002 Rev. Q
T60 Operations and Service Manual
CABLE TENSIOMETER
T60
PART NUMBERS:
T60-1001-C8-1A (NSN: 6635-00-530-1128)
T60-1001-C9-1A (NSN: 6635-00-530-1129)
T60-1002-C8-00 (BRITISH MODEL FOR CWT CABLES)
T60-1002-C9-00 (BRITISH MODEL FOR CWT CABLES)
SERIES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T60-1001-C8-1A and is the answer not in the manual?

Questions and answers

Summary of Contents for Optimanufacturing T60-1001-C8-1A

  • Page 1 OPERATION & SERVICE MANUAL FOR CABLE TENSIOMETER SERIES PART NUMBERS: T60-1001-C8-1A (NSN: 6635-00-530-1128) T60-1001-C9-1A (NSN: 6635-00-530-1129) T60-1002-C8-00 (BRITISH MODEL FOR CWT CABLES) T60-1002-C9-00 (BRITISH MODEL FOR CWT CABLES) SOP-TN-002 Rev. Q T60 Operations and Service Manual...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION AND DESCRIPTION ............................ 2 1-1. INTRODUCTION ............................2 1-2. PURPOSE - .............................. 2 1-3. DESCRIPTION - ............................2 1-4. WARRANTY - ............................2 Table 1- Type Identification .............................. 2 SPECIAL SERVICE TOOLS ..............................3 2-1. SPECIAL SERVICE TOOLS ........................3 PREPARATION FOR USE, STORAGE, and SHIPMENT ......................
  • Page 3: Introduction And Description

    The warranty can be void if the unit has been tampered, altered, dropped or damaged by an accident. All returns must have a Return Material Authorization (RMA) number. In order to obtain a RMA, please contact our Quality Department via email, jorge@optimanufacturing.com, or via fax: (787) 889-2805. Table 1- Type Identification MFR’S...
  • Page 4: Special Service Tools

    SECTION II SPECIAL SERVICE TOOLS SPECIAL SERVICE TOOLS 2-1. - No special tools are required for service or maintenance of the cable Tensiometer. SECTION III PREPARATION FOR USE, STORAGE, and SHIPMENT 3-1. PREPARATION FOR USE - The cable Tensiometer is shipped by the manufacturer in its own carrying case and is ready for use, for avoid damage on common use, the operator shall be use the Wrist Band adjustable, see figure 1.1.
  • Page 5: Operation Instructions

    RIGHT CALIBRATION BAR BOTTOM LEFT DOWN RISER CABLE GAGE POINTER LOCK BUTTON JAW BASE DIAL FACE SECTOR CABLE GAGE STOP PIN ACTUATING HANDLE POINTER UNLOCK BUTTON PRESET ACTUATING HANDLE LATCH RING 1 1 2 " 4 1 2 " 38.1mm 114.3mm T60 TENSIOMETER CABLE...
  • Page 6: Operating Instructions

    4-2. OPERATING INSTRUCTIONS - Either the right- or left-hand may be used to operate this instrument. The handle latch retains the actuating handle. The latch is automatically released when the actuating handle is squeezed. To re-latch the actuating handle, the handle must be squeezed firmly against the side of the Tensiometer and the handle latch pushed up from the bottom against its spring load and held in the extended position while the actuating handle is slowly released against the handle latch.
  • Page 7: Taking Cable Tension Readings, Type C8

    4-4. TAKING CABLE TENSION READINGS, TYPE C8 a. Preset dial by rotating the knurled rim of the dial indicator until the pointer is directly over the line corresponding to the cable diameter.(See Figure 3a) SET POINTER DIRECTLY SET POINTER OVER CENTER OF LINE OVER CENTER OF WHEN READING TENSION LOADS LINE TO THE CABLE DIAMETER...
  • Page 8: Taking Tension Readings, Type C9

    4-5. TAKING TENSION READINGS, TYPE C9 - The Type C9 cable Tensiometer is used in the same manner as the Type C8 with the following exception: the larger size cables have two rows of preset squares, one row identified by 250-, the other row identified by 250+. When measuring cable tensions below 250 pounds use corresponding squares in the row indicated by 250- and conversely, for the opposite condition, use 250+.(See Fig.
  • Page 9: Type Of Cable

    *Due principally to the uneven surface of the stranded cables, slight variations in readings may occur on the same cable at the same tension. If closest possible accuracy is desired take three or five readings at slightly different locations on the cable and average them. 4-8.
  • Page 10: Section V

    SECTION V PERIODIC INSPECTION, MAINTENANCE, AND LUBRICATION GENERAL - 5-1. No periodic inspection, maintenance, or lubrication is required for cable Tensiometers. As a matter of general practice, the instrument should be kept clean at all times. Particular attention should be paid to the two sectors and the riser block to see that they are always free from foreign matter.
  • Page 11: Section Vii

    SECTION VII CALIBRATION EQUIPMENT REQUIRED - 7-1. Calibrating the cable Tensiometer it will be necessary to have aircraft cables of various sizes and a method of accurately loading these cables with a range of loads from 10 to 450 pounds. DISASSEMBLY PRIOR TO CALIBRATION - 7-2.
  • Page 12: Indicator Cable Size

    Repeat steps i and j for 1/16” cable on Type C8 and 1/8” cable on Type C9, to improve indicator accuracy to +/- 5 % (If closest possible accuracy is desired take three to five reading at slightly different locations on the cable and average them). On step j for 1/16” & 1/8” cable on Type C8 the low end is 10 lbs.
  • Page 13: Section Viii

    SECTION VIII GROUP ASSEMBLY PARTS LIST Figure 6- Cable Tensiometer, Type C8 and C9 SOP-TN-002 Rev. Q T60 Operations and Service Manual...
  • Page 14: Table 6 Part List

    Table 6 Part List FIG. & UNITS USABLE PART NUMBER INDEX DESCRIPTION ASSY CODE T60-1001-C8-1A TENSIOMETER ASSY, Cable REF. T60-1001-C9-1A TENSIOMETER ASSY, Cable REF. T60-1002-C8-00 TENSIOMETER ASSY, Cable-British Model REF. T60-1002-C9-00 TENSIOMETER ASSY, Cable-British Model REF. COML # 0901100-55 . SCREW, 4-40 x ½ inch long Phillips oval head T60012 .
  • Page 15 Phone: (787) 889-2285 / Fax: (787) 889-2805 fax  Copyright . OPTI Manufacturing Corp. All Rights Reserved Point of Contacts: General Info: info@optimanufacturing.com Sales/Shipment: sales@optimanufacturing.com Technical Support/RMA is: jorge@optimanufacturing.com For the latest revision of this manual, refer to our website.
  • Page 16 REVISION HISTORY Previous Actual Effective Change Description Revision Revision Date 2/9/2006 Section VII- Calibration procedures updated 8/26/2006 Table 1-1 & Section VII revised 3/16/2007 Section 1-4 added 7/13/2007 Section 5-1 & table of Figure 8-1 revised 4/1/2009 Update Fig., Table (Sec.8), Change the number identification to Tables and Figures. Update Figure 3, Add Figure 3.5, Tables 2, 4, Sections 4-3, 6-1 and 7-2, TABLE 7, 8/19/2010 change the Manual title.