HINGMED WBP-03D User Manual

Wearable ambulatory blood pressure monitor

Advertisement

CE
0120
Hingmed
Wearable Ambulatory Blood Pressure Monitor
User Manual
(Apply to:WBP-03D for home use)
Shenzhen Hingmed Medical Instrument Co., Ltd.
VER:A/0
Date: March 15, 2015
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WBP-03D and is the answer not in the manual?

Questions and answers

Summary of Contents for HINGMED WBP-03D

  • Page 1 0120 Hingmed Wearable Ambulatory Blood Pressure Monitor User Manual (Apply to:WBP-03D for home use) Shenzhen Hingmed Medical Instrument Co., Ltd. VER:A/0 Date: March 15, 2015...
  • Page 2 Fax: +353(1)6864856 Web: www.CE-marking.com Email: AuthRep@CE-marking.eu Version Information This manual may upgrade due to software upgrading. User will not be notified further. ■ Version: A/0 ■ Issue date: March 2015 Shenzhen Hingmed Medical Instruments Co., Ltd. owns and reserves the copyright.
  • Page 3: Table Of Contents

    4.3.2 Software requirements ............ 错误!未定义书签。 4.3.3 Install the software ............错误!未定义书签。 4.4 Execute Ambulatory Blood Pressure Study (PC terminal) ..错误!未定义书签。 4.4.1 Communication with Hingmed ABPM ......错误!未定义书签。 4.4.2 Connect monitor to computer .......... 错误!未定义书签。 4.4.3 Continuous measurement programming ......错误!未定义书签。...
  • Page 4 4.6.4 Store and extract measurement data ............15 4.6.5 Finish measurement and data derive............15 Chapter 5 Troubleshooting and Maintenance ..............15 5.1 Troubleshooting ..................... 15 5.2 Maintenance ......................16 5.2.1 Maintenance inspection and safety management ........16 5.2.2 Host Maintenance ..................16 Chapter 6 Product specifications ..................
  • Page 5: Chapter 1 Preface

    Chapter 1 Preface Brief Introduction to Ambulatory Blood Pressure Monitoring Ambulatory blood pressure monitoring is an instrument for monitoring human’s blood pressure continuously during certain period (normally 1-2 days) with certain interval that is based on actual situation. Blood pressure readings in different periods and under different life conditions can be judged according to the measuring results, thus blood pressure diagnosis would be given.
  • Page 6 For the following hypertension types, it is only ambulatory blood pressure monitoring that could diagnose easily. 1. white-coat hypertension White-coat hypertension is the blood pressure that is high when measured at health care site but normal in daily activity. The high pressure at health care site is repeatable in different days.
  • Page 7: Chapter 2 Safety Requirements

    1.2 Brief Introduction of Hingmed Wearable ABPM Blood Pressure Monitor with Body Position Information Hingmed ambulatory blood pressure monitor has an outstanding feature that it could provide the user's body position when taking blood pressure measurement, which is of significance in clinical research. Some symptoms of hypertensive patients, such as dizziness, nausea, brain death, are caused under dynamic environment of working or other life.
  • Page 8: Contraindication

    Product composition: Main unit, Noninvasive blood pressure cuff, USB data wire and Hingmed PC software. The device is inner power source with one piece of Lithium battery; Electric shock protection degree: CF type applied part; Operation mode: continuous mode. The service life of this product is five years.
  • Page 9: Notice

    ● Please properly handle the scrapped batteries, cuff, data wires and main units in compliance with local environmental regulations. 2.4.5 Maintenance ● Please use the accessories supplied by Hingmed, otherwise it may cause measuring errors. ● Maintenance should be conducted only by trained personnel or personnel authorized by Hingmed.
  • Page 10: Chapter 3 Product Introduction

    Prior to use please confirm if accessories are complete, and if there is any damage on main unit and accessories, any problem above is found, please contact distributors or Hingmed customer service hotline for help. Main unit, accessories include blood pressure cuff, and USB wire for charging.
  • Page 11: Oled Screen Displays And Icon Implication

    1 OLED screen; 2 Cuff; 3 Backward button; 4 Power on/off button (Closing state) and Start/stop button (Open state); 5 Forward button; 6 USB port. 3.2.2 OLED screen displays and icon implication Diastolic pressure Systolic pressure Diastolic and systolic pressure values indicated after measuring Unit of diastolic and systolic pressure Heart rate value indicated after measuring...
  • Page 12: Chapter 4 Product Installation And Use

    USB. 4.2 Wear the monitor Hingmed wearable ABPM is integration design, it suggests wearing the cuff on left arm, click the power on/off button (the middle button) to open the monitor, and press it for about 5 seconds to close the monitor.
  • Page 13: Installing System (Pc Terminal)

    4.3.3 The Bluetooth matching and connection For Android phone, enter “Setting”---“Bluetooth” (at the time, keep the Bluetooth of monitor open), search the Bluetooth of monitor (“Hingmed WBP”) and make pairing. Click to open software APP and enter “More” ---“Bluetooth setting” and choose “Hingmed WBP”...
  • Page 14: Execute Ambulatory Blood Pressure Study (Smart Mobile Terminal)

    4.4 Execute Ambulatory Blood Pressure study (Smart mobile terminal). 4.4.1 Communicate with Household Ambulatory Blood Pressure Monitor Connect monitor and handhold terminal through Bluetooth, program the software of handhold terminal and start monitoring to execute 24-hour Ambulatory Blood Pressure study. Monitor will measure the pressure according to the set interval. 4.4.2 Program Ambulatory Blood Pressure Monitor software Program software after successful connection as followings: Click...
  • Page 15: Store And Extract Measurement Data

    Note: 1. Operation details of Mobile phone software of Hingmed Wearable Ambulatory Blood Pressure Monitor, please refer to < User Guide of APP software >; 2. The monitor could store maximum 300 hundred records. When storage is full, the monitor can’t save data normally until programming it from smart mobile...
  • Page 16: Maintenance

    EC48 Memory is full, can no longer measure Upload and empty the data * If the errors can be revised, please call distributor or after-sale department of Hingmed for help. 5.2 Maintenance 5.2.1 Maintenance inspection and safety management Visually inspect the broken or damages on enclosure and cuff. If any damage is found, do not use the monitor.
  • Page 17 Remove the bladder from the cuff before machine washing. Wash them by using warm water and a mild detergent, then hang it for drying. Any problem, please contact local distributors or Hingmed (see Chapter 8 for information).
  • Page 18: Chapter 6 Product Specifications

    Chapter 6 Product specifications Name Wearable Ambulatory Blood Pressure Monitor Model WBP-03D measuring method Oscillometric method Systolic blood pressure 40-260 mmHg measurement range Diastolic blood pressure 20-210 mmHg measurement range...
  • Page 19: Chapter 7 Emc Information

    Guidance and manufacture’s declaration – electromagnetic emission is intended for use in the electromagnetic environment specified below. The customer of WBP-03D the user of the should assure that it is used in such an environment.
  • Page 20 Guidance and manufacture’s declaration – electromagnetic immunity The WBP-03D is intended for use in the electromagnetic environment specified below. The customer or the user of WBP-03D should assure that it is used in such an environment. IEC 60601 test Compliance...
  • Page 21 Portable and mobile RF communications equipment should be used no closer to any part of the WBP-03D, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance...
  • Page 22 RF communications equipment and the WBP-03D . The WBP-03D is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the WBP-03D can help prevent electromagnetic interference...
  • Page 23: Chapter 8 Warranty Card

    Hingmed. This limited warranty contains the entire obligations of Hingmed, exclud other expressed, implied or regulated warranties. Representatives or employees without authorized by Hingmed will assume any further liability or grant any further warranties except as set herein.