Page 2
AA - 700 0 Ser ie s Atomic Abso rp ti o n Sp ectro p h o to meter s Reaching Even Greater Heights Enhanced Flame Analysis World-Class High-Sensitivity Furnace Improved Dual Atomizer System Advanced Safety Technology...
Page 4
System Configuration can Evolve with Your Needs The AA-7000 Series can be upgraded by adding units to allow the system to handle the analysis targets. The AA-7000 Series can be upgraded by adding units to allow the system to handle the analysis targets.
Page 5
AUTO AA-7000F/AAC Dual Atomizer System Auto Atomizer Autosampler Changer AUTO Dual Atomizer System Graphite Furnace Automatic adjustment of atomizer Atomizer Automatic serach of burner height *1 Requires ASC stand kit. *2 Requires ASK-7000. *3 Automatic burner height search function can be used. AA-7000F/AAC equips with AAC as standard.
Page 6
Hollow cathode lamp Double-Beam Optics and Stable Hardware Achieve Superior Stability The AA-7000 Series incorporates newly developed 3D double-beam optics. The optical system has been designed to produce its maximum performance for each measurement method through optimal adjustment of the light beam and light beam digital filter, and by using optical components that restrict light...
Page 7
Advantages of the Double-Beam System Long-term stability High sensitivity The graph shows the results of The graph shows the direct measurements on 2 ppm copper (Cu) measurement results for 0.1 conducted over at least one hour. ppm lead (Pb). (The plot shows mean values for 11 repeated measurements.) Over the course of more than 600 Measurement time...
Page 8
(comparison with previous P b 0 . 08 p p b 0 .0 5 pp b Shimadzu models). This superb analysis performance is possible in all fields. M n 0 .0 2 p pb...
Page 9
High-Performance Autosampler Mix and inject up to four sample types (diluted solution, standard solution, sample, matrix modifier, etc.). (Of course, unmixed samples can also be injected.) Select a fluororesin tube or pipette tip as the injection nozzle. Automatic dilution and re-analysis if the calibration curve concentration is exceeded. Example of Automatic Dilution and Re-Analysis Analysis of cadmium (Cd): The maximum concentration of the calibration curve has been set to 1ppb.
Page 10
Improved Dual Atomizer System Single Unit Handles High Concentration to Trace Analysis Samples AA-7000F/AAC creates an integral burner and furnace that remains permanently installed in the combustion chamber. It supports both flame analysis of high concentration samples and furnace analysis of trace samples, without changing the atomizer unit.
Page 11
* Shimadzu in-house investigation. Current as of November 2008. Lamp house Just slide the cover to the side for easy replacement of the hollow cathode lamps through the large opening.
Page 12
Safety is an extremely important consideration for flame atomic absorption spectrophotometers using acetylene gas. The AA-7000 Series instruments are the first* ones in the world fitted with a vibration sensor as standard. They also incorporate a comprehensive range of safety mechanisms, including gas leak detectors.
Page 13
Safety Functions for Flame-Specification Instruments World first! –– flame extinguished automatically by vibration sensor The flame is automatically extinguished when the new built-in sensor detects vibrations. Instruments are completely safe during severe shaking caused by earthquakes. Multimode automatic gas leak check The fuel gas pipes inside the instrument gas controller are automatically checked for gas leaks when the power is turned on and when the flame is extinguished.
Page 14
Dual-Background Correction Functions The optimal background correction methods are installed as standard: high-speed self-reversal method (SR method) and deuterium lamp method (D method). These functions can correct for spectral interference in flame measurement. Selecting the optimal background correction method for each sample ensures accurate and reliable analysis results.
Page 15
Examples of elements and wavelengths causing spectral interference problems due to neighboring lines Measured Element Analytical Line (nm) Coexisting Element Absorption Line (nm) 3 09.2 8 3 0 9 .3 0 1 93.7 6 1 9 3 .7 3 4 22.6 7 4 2 2 .6 4 2 28.8 0 2 2 8 .8 4...
Page 16
Clear, Easy-to-Use Software Features of the WizAArd Software Features of the WizAArd Software Features of the WizAArd Software The WizAArd software used with the AA-7000 runs under Windows 7/ Vista/XP. The WizAArd software used with the AA-7000 runs under Windows 7/ Vista/XP. The WizAArd software used with the AA 7000 runs under Windows 7/ Vista/XP Wizard Functions Make Setting the Conditions So Simple That Even a Novice Can Do It.
Page 17
Software Provides Comprehensive Information Displays and Flexible Settings Software Provides Comprehensive Information Displays and Flexible Settings Sof f tware Provides Comprehensive Information Displays and Flexible Settings Identical software operation for flame and furnace measurements Identical software operation for flame and furnace measurements Identical software operation for flame and furnace measurem Even if the calibration curve is created after sample measurements, Even if the calibration curve is created after sample measurements,...
Page 18
FDA 21 CFR Part 11 Compliance FDA 21 CFR Part 11 Compliance A combination of enhanced WizAArd software with Shimadzu's network-compatible CLASS-Agent data management software supports FDA 21 CFR Part 11 Compliance. WizAArd used alone provides comprehensive system policy setting, user management, log browser, audit trail, and electronic signature system management functions.
Page 19
When combined with the autosampler, it automatically determines the wavelength accuracy, noise level, baseline drift, absorbance and repeatability, and prints out the results of comparison with the pass criteria. * Data from all Shimadzu analytical instruments can be centrally managed by CLASS-Agent.
Page 20
Standard Parts / PC / Software Common to All AA-7000 Series Models Part Name Quantity Cable set 071-60821-08 (120 V), 071-60825-51 (230 V) Cards (set of 10) 206-52046-91 Instruction manual 206-97176 206-97225 Safety inspection sheet (safety instruction) Declaration of conformity, explanatory notes (ISO-9001)
Optional Accessories For Flame Analysis Part Name Remarks High-temperature burner head 206-77530-91 Made of pure titanium. Air-cooled. 5 cm slot for N flame Extremely corrosion-resistant Can also be used for Air-C flame. Flow meter kit 206-77617-41 Float-type flow meter for support gas Dimensions: 250 W ×...
Page 22
Environmental standards prescribe the hydride generation method as one method of As, Se, and Sb analysis. 1. Used with the AA-7000 Series, HVG-1 permits the rapid and accurate quantitation of elements such as As, Se, Sb and Hg at several-ppb levels.
Page 23
For High-Sensitivity Hg Analysis Part Name Remarks MVU-1A mercury vaporizer unit 206-58780-XX This mercury vaporizer unit permits analysis using the reduction vaporization –– atomic absorption method. It permits easy, high-sensitivity water quality analysis. ISpecifications Vaporization method: reduction vaporization with a reducing agent Measurement method: recirculation Flow cell: optical path length 100 mm (with quartz window) Sample volume: 250 mL max.
Specifications Main Unit Basics Wavelength range 185.0 to 900.0 nm Monochromator Aberration-corrected Czerny-Turner mounting, Number of grating grooves: 1800 lines / mm, Focal length: 300 mm Bandwidth 0.2, 0.7, 1.3, 2.0L nm (4-step automatic switching) Detector Photomultiplier tube Optics Optics Optical double-beam BGC-SR (high-speed self-reversal method) (185.0 to 900.0 nm) Background correction method...
Page 25
Controller: 235 W × 110 D × 240 H mm (built into GFA-7000A), 6 kg Required Software Operation Environment Shimadzu recommends the PC and monitor in the PC Set for AA-7000 Series with WizAArd Software Pre-Installed. Purchase a printer separately. The personal computer and monitor specifications are as follows.
Page 26
Installation Conditions Dimensions Dimensions Wall Wall Table Table ø150 to ø200 ø150 to ø200 Exhaust fan Exhaust fan Damper Damper ø150 to ø200 ø150 to ø200 Damper Damper Approx. 500 × 500 Approx. 500 × 500 4 4 15 Both for flame analysis and furnace analysis Both for flame analysis and furnace analysis For furnace analysis For furnace analysis...
Page 27
Make sure all required equipment is available before starting instrument installation. See the installation guidelines for details. Make sure all required equipment is available before starting instrument installation. See the installation guidelines for details. Example of recommended piping for the atomic absorption system Example of recommended piping for the atomic absorption system Temperature range Temperature range...
Page 28
For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.