Page 1
Honeywell HWLKS-C-M-1918 INSTALLATION&OPERATION GUIDE BOOK EXPTZ Camera (HIGH SPEED) Explosive proof Security Camera The EXPTZ Series follow the stringent explosion-proof requirements with creative mechanical strength and design. Moreover, the EXPTZ explosion-proof system is designed to meet the rigorous requirements of explosion-proof electrical equipment installed in hazardous locations.
Honeywell HWLKS-C-M-1918 Contents Important Safety Instructions ----------------------------------------------------------- Method of Installation ---------------------------------------------------------------------- Maintenance ----------------------------------------------------------------------------------- Base Schematic ------------------------------------------------------------------------------ Wire and Power Connection Guide ---------------------------------------------------- Simple Function Control Guide --------------------------------------------------------- Program and Operation -------------------------------------------------------------------- Specifications --------------------------------------------------------------------------------- Remote Controller --------------------------------------------------------------------------- Optional Accessories ---------------------------------------------------------------------- EXWJ400 Schematic & Operating ----------------------------------------------------...
Use stainless steel hardware to fasten the mount to outdoor surfaces. A readily accessible disconnect device shall be incorporated in the building installation wiring. Only use replacement parts recommended by Honeywell. The maximum ambient temperature range is -20℃ to 50℃. Explanation of Graphical Symbols.
Honeywell HWLKS-C-M-1918 Methods of Installation This system can be installed in a standard as below Figure1. If you wish to install another method, you must do it after discussing with a manufacture.aas Figure1. Standard Method of Installation WARNING: Gross weight of this system is about 40kg. Use caution when lifting and installing.
Page 5
Honeywell HWLKS-C-M-1918 Methods of Installation Sealing Fiber Filler compound Cables Sealing Method Explosion proof PT 3/4”-14 Nipple Flexible conduit PT 3/4 “-14 Seal Fitting Figure2. Standard Method of Installation To install this system, please refer to Figure2 and do the following steps.
Honeywell HWLKS-C-M-1918 Maintenance Description Q’TY Camera Housing Assy Tilt Drive Assy Elbow Housing Pan Drive Assy Base Housing Hexagon Socket Head Cap Screws 28EA Hexagon Head Screws Hexagon Socket Head Screws Figure3. To disassembly this product, please refer to Figure3 and do the following steps.
Page 7
Honeywell HWLKS-C-M-1918 Maintenance 1. Make the wiper vertical 2. Depart the cover with and depart the clamp. twist. 3. Loosen the two screws from housing and put out the camera bracket and loosen other screws to depart the camera, bracket and PCB,...
Page 8
Honeywell HWLKS-C-M-1918 Maintenance 2. Loosen the Wiper Head and depart 1. Loosen the two screws on the bracket. the wiper motor assembly. 2. Loosen the Hexagon socket head screws and depart the wiper bar from the wiper head. It can be changed as the expendable supplies.
Honeywell HWLKS-C-M-1918 Base Schematic POWER AC100~ 240V RS 485 RS 485 Alram out MAIN MONITOR J-BOX FRONT RS 485 DATA 2 DATA 1 DC 12V SLAVE 1 DOME 2 RS 232C ALARM/DVR J-BOX REAR DATA1 DATA2 DC 12V REAR KEYBOARD CONTROLLER HTX-5000 Figure4.
Honeywell HWLKS-C-M-1918 Wire and Power Connection Guide POWER AC 100V ~ 240V ALARM & DATA Configuration of Wire Harness Wire Color Function Description Brown Power Input SkyBlue (AC 100V ~ 240V) Alarm 1 Orange Alarm 2 Yellow Alarm Input Alarm 3...
Honeywell HWLKS-C-M-1918 Simple Function Control Guide * This function is specialized to HTX-5000 keyboard. Function Process Results Remarks To matching ID 01 of 01~99. Only in full screen PAN/TILT ①Press (CAM) button mode. If ID set 02, press (Cam) in sequence.
Page 12
Honeywell HWLKS-C-M-1918 Simple Function Control Guide Function Process Results Remarks ① Press (Menu) button. -Menu screen is displayed. (95+ Preset) at Pelco Protocol -Go into the sub-menu items. ② Move Joystick to the right Change value. Menu or left. Navigate through the menu items ③...
Honeywell HWLKS-C-M-1918 Program and Operation Camera ID Selection Before you start programming or operating a camera, you should make the camera be under control of the joystick controller. In other words, the dome camera that you want to effect changes must be currently selected.
Page 14
Honeywell HWLKS-C-M-1918 Program and Operation Locate the cursor on the FUNCTION item and then push the joystick to the right to enter FUNCTION menu. FUNCTION HOME FUNCTION PRESET SCAN TOUR EXIT MENU 1.1 HOME FUNCTION ( MENU =>FUNCTION => HOME FUNCTION) After HOME FUNCTION item has been selected, follow the directions below to set HOME function.
Page 15
Honeywell HWLKS-C-M-1918 Program and Operation 7.Pushing the Joystick down and twist the Joystick to CCW/CW (or push the stick to right/left) to set waiting time. 8. Locate the cursor on OPERATION option by pushing the Joystick down. Choose operation status Enable or Disable by pushing the Joystick to the right or to the left (or twist CCW/CW).
Page 16
Honeywell HWLKS-C-M-1918 Program and Operation Follow the steps below to program the Preset positions. Select the camera number by pressing 0 ~9 and CAM. Simply press PRST button to enter preset menu. ( MENU => FUNCTION => PRESET) Select the empty preset location to be programmed using the Joystick up/down. If selected location is not empty, pressing PRST button will show your predefined position.
Page 17
Honeywell HWLKS-C-M-1918 Program and Operation 1.3 SCAN ( MENU => FUNCTION => SCAN or Shortcut: SCAN) The Scan function supports up to 16 programmed section of angles at 8 programmable speeds SCAN MENU 01/08 SCAN 01 : AUTOSCAN01 SPEED : 1~8/SLW/MID START : 127.1, 027.0 zoom...
Page 18
Honeywell HWLKS-C-M-1918 Program and Operation 8. Push the Joystick downward to select “SWAP” and set the swap by moving the Joystick left and right to select the swap ON or OFF. 9. Select Save and Exit by pushing the Joystick to the right. Press ESC to exit the program without saving.
Page 19
Honeywell HWLKS-C-M-1918 Program and Operation Follow the steps below to program the Tours: Press MENU => FUNCTION => TOUR, Short Cut: TOUR MENU to display the main menu on the monitor. No. + SHFT+TOUR will open directly Tour No. Choose an empty location of function by pushing the Joystick up or down.
Page 20
Honeywell HWLKS-C-M-1918 Program and Operation 2. ALARM ( MENU => ALARM) MAIN MENU FUNCTION ALARM SCREEN CAMERA SETUP PASSWORD COMMUNICATION EXIT MENU Locate the cursor on ALARM item in the main menu and push the joystick to the right for ALARM programming of the camera.
Page 21
Honeywell HWLKS-C-M-1918 Program and Operation Press Menu to display the main menu on the monitor. Select the Alarm option by pushing the Joystick up or down and push to right to enter the detail menu. Select the alarm input number by pushing the Joystick up or down and select the column you wish to setup.
Page 22
Honeywell HWLKS-C-M-1918 Program and Operation 3.1 LANGUAGE( MENU => SCREEN => LANGUAGE) Current, Language supports the only English. 3.2 PRIVACY ZONE ( MENU => SCREEN => PRIVACY ZONE) Locate the cursor on the PRIVACY ZONE item and then push the joystick to the right to enter the menu.
Page 23
Honeywell HWLKS-C-M-1918 Program and Operation Select the Privacy Zone option by pushing Joystick Up or Down and push to right to enter the detail menu. Select the privacy zone number by pushing the Joystick up or down. To enter the zone name, rotate the handle clockwise or counterclockwise. You can select alphanumeric characters by rotating the handle.
Page 24
Honeywell HWLKS-C-M-1918 Program and Operation 3.3 NORTH DIRECTION ( MENU => SCREEN => NORTH DIRECTION) Push the joystick handle to the right to select NORTH DIRECTION options SCREEN MENU LANGUAGE PRIVACY ZONE NORTH DIRECTION :000.0 ZONE TITLE CAMERA TITLE : EXPTZ...
Page 25
Honeywell HWLKS-C-M-1918 Program and Operation Press MENU => SCREEN => ZONE TITLE to display zone title menu on the monitor. Select the zone number by pushing the Joystick up or down. Select Start, End or number column to be set by pushing the handle to the right or left. The selected column will be highlighted.
Page 26
Honeywell HWLKS-C-M-1918 Program and Operation 3.6 OSD DISPLAY ( MENU => SCREEN => OSD DISPLAY) Push the joystick handle to the right to select OSD DISPLAY options SCREEN MENU LANGUAGE PRIVACY ZONE NORTH DIRECTION :000.0 ZONE TITLE CAMERA TITLE : EXPTZ...
Page 27
Honeywell HWLKS-C-M-1918 Program and Operation 4. CAMERA ( MENU => CAMERA) NOTE: The menu features will vary depending on the camera module installed in your EXPTZ camera. CAMERA MENU FOCUS CONTROL : AUTO / MANUAL WB CONTROL AE CONTROL BLC SETUP...
Page 28
Honeywell HWLKS-C-M-1918 Program and Operation 4.3 AE CONTROL ( MENU => CAMERA => AE CONTROL) Depending on your dome camera, you will see either the following screen or the next. AE SETUP MODE : FULL AUTO SLOW SHUTTER : x10...
Page 29
Honeywell HWLKS-C-M-1918 Program and Operation 4.4 BLC SETUP ( MENU CAMERA BLC SETUP) Objects in front of bright backgrounds will be clearer with BLC ON/AUTO/BMB. *) BMB [Black Mask BLC] : It is another function of BLC. It mask the excessive light to dark level and make brighter to see object around the excessive light.
Page 30
Honeywell HWLKS-C-M-1918 Program and Operation 4.6 DIGITAL ZOOM ( MENU => CAMERA =>DIGITAL ZOOM) DIGITAL ZOOM SETUP : OFF : ON POSITION : R.TOP EXIT MENU MAX : OFF(Optical zoom only) / 2x / 4x / Max(Digitally magnifies up to 2x, 4x 8x 16x respectively) PIP(Picture in Picture) : ON / OFF POSITION : R/BOT / R.TOP / L.BOT / L.TOP...
Page 31
Honeywell HWLKS-C-M-1918 Program and Operation 5. SETUP ( MENU => SETUP) SETUP MENU FLIP FUNCTION : ON P/T SPEED : FAST PRESET FREEZE : OFF RESET ORIGIN FACTORY DEFAULT ERASE DATA SYSTEM INFORMATION SAVE AND EXIT 5.1 FLIP (MENU => SETUP => FLIP)
Page 32
Honeywell HWLKS-C-M-1918 Program and Operation 5.5 FACTORY DEFAULT (MENU => SETUP => FACTORY DEFAULT) FACTORY DEFAULT ARE YOU SURE ? YES : ENTER OR MENU KEY NO : ESC KEY Programmed data go back to initial state as ex-factory 5.6 ERASE DATA (MENU => SETUP => ERASE DATA )
Page 33
Honeywell HWLKS-C-M-1918 Program and Operation 6. PASSWORD ( MENU => PASSWROD) PASSWORD SETUP MENU PASSWORD : ON/OFF CHANGE PASSWORD : **** CONFIRM : **** SAVE AND EXIT Change password : Move the joystick handle right and up or down to select number 0~9(a number of four figures), and do same way to confirm.
Honeywell HWLKS-C-M-1918 Specifications Mechanical Part Models EXPTZ252/363NA EXPTZ252/363PA Spec Signal System NTSC Ex. Class Ex d IIC T6 ( IECEx, ATEX, CE, FCC, KC, CCEs ) Front window Ground and polished, fully tempered plate glass Construction SUS 316 Protection Degree IP 67 Angle: 360°...
Honeywell HWLKS-C-M-1918 Remote Controller 1. POWER Power on/off. 2. NUMBERS Numeric keypads (0~9), 3. Camera Address (ID) Change camera ID. Number + CAM 4. WRITE PRESET(1~99) Saves camera picture’s condition. Number + SAVE 5. PRESET(1~99) Recall preset. Number + PRESET 6.
Honeywell HWLKS-C-M-1918 Optional Accessories Note: These Mounting Accessories are not supplied with the EXPTZ Series units. These are purchasing parts. Models 1. EXPTZ-WL: Wall mount bracket designed to mount the EXPTZ Series Camera directly to a load-bearing vertical surface. 2. EXPTZ-CN: Corner adapter Bracket for use with the EXPTZ-WL to mount the EXPTZ Series Camera to the corner of a structure.
Page 38
Honeywell HWLKS-C-M-1918 Optional Accessories EXPTZ-WL Unit (mm) EXPTZ-CN Unit (mm) - 38 -...
Honeywell HWLKS-C-M-1918 EXWJ400 Schematic & Operating POWER AC 100~240V RS 485 EXPTZ Series RS 485 Alram out Check Valve MAIN MONITOR EXWJ400 Pump Motor J-BOX FRONT RS 485 DATA 2 DATA 1 DC 12V SLAVE 1 DOME 2 RS 232C...
Page 42
Honeywell HWLKS-C-M-1918 EXWJ400 Schematic & Operating [ Do following step to operate water jet function ] Save the location of nozzle position (washing) on Preset 59. * First of all, The EXPTZ pan/tilt direction should be decided and saved that window glass of camera housing toward nozzle of water jet on preset 59.
Honeywell will repair or replace, at its sole option, free of charge, any defective products returned prepaid. In the event you have a problem with any Honeywell product, please call Customer Service for assistance or to request a Return Merchandise Authorization (RMA) number.
Page 46
Honeywell Security Group. Honeywell Co., Ltd. Printed in Korea G-113497-02...