6. Some notices, into a same section are generic therefore cannot be directly linked to a spare part. In order to assist a model in the best way as possible, it is helpful to pay attention to all notices and constantly verify documentation updates 7.Technical documentation cover shows model name and its commercial codes mod.AWD129NA page 2...
Page 6
1 x C00094280 C00092273 hose dispenser to tank C00096077 bearing spider assembly n1040300 C00074211 drum pulley d=210 mm h=20 mm C00118629 belt l=1046 - 1051 mm h8 C00110163 shock absorber elastic pin C00001109 loctite 270 10 gr. mod.AWD129NA page 6...
Page 7
1180240 Spare parts list Ref. Code From To S/N Substitute Description Notice Industrial C00033026 ambljgon grease ta 100 gr. mod.AWD129NA page 7...
Page 12
- condenser / tank C00032972 blower fixing nut C00080658 blower fan for motor (087920- C00054790 screw trilob m5 x 16 tcb t.e. st C00087919 blower manifold kit C00110434 dryer fan motor 115v.60hz C00114390 fixing screw m8x25s mod.AWD129NA page 12...
Page 13
· loads the wash electrovalve and pre-wash electrovalve at the same time until the pressure switch is on full · heats up to 30° and moves the motor in both directions · selector moves on for 9 notches · drains and spins · the selector knob stops on one of the reset positions · STOP mod.AWD129NA page 13...
Page 14
F06: Selector Error (a part no. cannot be found) Overhaul CND (selector connector) Overhaul Selector Connector Control Selector/CND Continuity Control Selector Motor Replace Selector Replace Card F07: Resistance Relay Stuck Overhaul CN1 Overhaul CN1 Overhaul Resistance Connection Replace Card mod.AWD129NA page 14...
Page 15
Overhaul Pressure Switch Connector Control Pump Windings Replace Pump Replace Card F12 SPECIFIC FOR LVB2000 INDESIT EVOLUTION / DIALOGIC. F12: Lack of Display card-Main Card Communication 1. Check the effectiveness of contacts on CNC Connector Card 2. Overhaul 8-way connector on Display card 3.
Page 16
5. Replace card N.B.From Fault F01 to fault F11 These are shown by LEDs in stand by/on in LVB2000 machines Ariston/Indesit. From fault F01 to fault F12 These are shown in a display located on the instrument panel of LVB2000 ma-chines Evolution Indesit.
Need help?
Do you have a question about the AWD129NA and is the answer not in the manual?