Page 1
Gas-Pro User & Operator Manual Click here Gas-Pro for navigation Multi-gas monitor instructions Click here fo contents list M07995/Eng Issue 11 Dec 2016...
Page 2
NAVIGATION INSTRUCTIONS Contents The symbols in the left-hand margin of each page of the manual will enable you to carry out the following functions: Contents Click on this button to display the Contents page. Click on this button to display the previous page. Click on this button to display the next page.
Gas-Pro is a portable monitor capable of detecting up to 5 gases in a compact and wearable design featuring an optional internal pump. Focused on users and fleet managers alike, Gas-Pro offers application focused solutions giving greater operating time and reduced set up time.
Contents • Gas-Pro is a hazardous area certified gas detector and as such must be operated and maintained in strict accordance with the instructions, warnings and label information included in this manual. Gas-Pro must be operated within the limitations stated.
Page 9
• Gas-Pro may be used in Zones 1 and 2, for Group llA, llB and llC gases and vapours and for Contents Temperature Classes T1, T2, T3 and T4. (see Certification labels below). • Certification labels The certification marking is as follows: Ex d ia IIC T4 Gb -20°C ≤...
Page 10
ATEX Contents EN 60079-0: 2012 + A11: 2013 Explosive atmospheres – Part 0: Equipment - General requirements EN 60079-1:2007 Explosive atmospheres – Part 1: Equipment protection by flameproof enclosures “d” EN 60079-11: 2012 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety “i” Prologue II 2 G Ex d ia IIC T4 Gb Tamb -20°C to +55°C Set-up...
Should the unit be deep discharged, the charging indication will not be shown until the unit has been charging for 1 hour and the operator button has been pressed. Troubleshooting When on and charging a warning will advise the user to turn the Gas-Pro off after 12 hours or remove from charge. Appendices Store the battery in a full state and recharge at least once every 3 months.
Before use, the Gas-Pro should always be checked for any signs of physical damage. Gas-Pro uses a Lithium Ion (Li-ion) battery pack and should arrive with sufficient charge to be used straight out the box. However, if this is the first time of use, you may need to charge the battery to...
À Accessories When off, to show the Gas-Pro is charging, both LEDs within the alarm bars will flash red and will change Specification to green once fully charged. This state will continue until the trickle charge is complete. Charging will then terminate showing no indication.
A flow plate can be used for a number of applications including pumped operation (remote sampling), manual gas test/calibration or for manual sampling. If the pumped flow plate is attached before turning the Gas-Pro on and the Gas-Pro includes a pump, a pump test will commence as part of the start up process (see...
1.5 Quick view Contents Even when the detector is off, users can display details about the configuration of the Gas-Pro by momentarily pressing the operator button for one audible blip. The LED to the left of the display will flash red once and the Quick view screen shown in Figure 6 below will be displayed for 10 seconds.
2.2 Turn on Prologue In ‘clean air’, turn on the Gas-Pro by holding down the operator button for 3 audible blips. The Gas- Pro will warm up, going through a series of automatic processes as follows: Set-up Firstly a test screen pattern will be generated.
Page 17
If the Gas-Pro is configured for regular Gas Testing (Bump Test), the date of the last Gas Test will Contents also be shown (for more information on Gas Testing, see Gas testing and calibration page 37). Figure 8: Gas test due screen...
Page 18
Accessories Specification Troubleshooting An Autozero should not be performed unless the Gas-Pro is in clean air. Press the operator button to enter the Autozero mode, otherwise the countdown will progress and will not perform a zero. Appendices If the operator button is not pressed the countdown will complete and this function will be skipped.
Page 19
When the autozero has finished or been skipped, the next screen is the home screen (Figure Contents and displays the gas levels. The next screen on the Tank-Pro edition of Gas-Pro is the Tank Check screen. See the Tank Check Mode section (see Section 2.9 page 34) for more information.
If the Gas-Pro is configured for Bump functionality, the Bump/Pump prompt will be displayed if a flow plate is attached and a gas bump test is due or the Gas-Pro is placed in a Q-Test module during normal use (see...
2.4.1 Diffusion monitoring If you wish to monitor gases in ambient air for dangerous levels, the Gas-Pro can be worn by either clipping the strong alligator clip to clothing/overalls in the breathing zone or through the use of a chest harness.
33). Gas-Pro can either be worn or used with hoses and probes to sample from spaces prior to entry. The pump capacity in the Gas-Pro is 0.5l/m and will draw a sample of gas from 30m within 80 seconds. Please note the expected losses for some gases below. Please allow at least 3 seconds per meter of hose used.
1 minute is recommended to ensure a stable sample is read. Maintenance If the Gas-Pro being used is fitted with a carbon monoxide sensor (CO) a 5% increase in reading is expected during this process due to the extra pressure placed on the sensor (ie if the sample being tested is 30ppm –...
Operation 2.5.2 Instantaneous alarm The Gas-Pro will go into alarm immediately if the level of any of the gases it is configured to detect become outside acceptable limits. A minimum and maximum acceptable level is set for oxygen, for most Gas testing other gases the Gas-Pro will go into alarm state 1 or 2 according to which level has been exceeded.
Set-up While in alarm, the Gas-Pro will continue to record levels of all the gases being monitored. Operation 2.5.5 Sensor types The Gas-Pro can be fitted with the following sensor types: Gas testing •...
While in saver mode and the subsequent stabilise time, the gas level displayed on the LCD screen will indicate over range. If the alarm is so severe as to cause a sensor over-range the Gas-Pro should have a gas test to ensure no lasting damage has occurred.
Page 27
Isobutylene by changing the correction factor in the PID sensor type options Details of how to change the VOC correction factor can be found in Portables Pro user manual Gas-Pro fitted with a PID sensor may require periodic cleaning and calibration of the sensor to ensure correct performance in normal use.
When this icon is selected, the Home screen will be displayed. Specification 2.6.3 Manual zero Troubleshooting This function should only be carried out in ‘clean air’ and allows the Gas-Pro to be zeroed at any time. Appendices Certain operations will only take place if the Gas-Pro has been recently zeroed .
This function is intended for sampling air of unknown quality before gaining access to it (e.g. going under ground through a manhole cover) thereby avoiding unnecessary exposure. The Gas-Pro (and any sampling probe) should be in a clean air when the PEC starts and finishes so the TWA accumulation should be insignificant.
To confirm the end of the purge stage single click the operator button within the 10 seconds or the purge will continue. Appendices The Tank-Pro edition of Gas-Pro will not display %VOL readings while in PEC mode. See the Tank Check Mode section (see Section 2.9...
Gas-Pro will create an event when the user is changed allowing traceability of the user. Maintenance 2.6.7.2 Pump setting This function, which is only present if the Gas-Pro has an internal pump, allows the user to turn the PC software pump on or off. Accessories Double click the operator button to select the function.
2.7 Shut down Contents To turn the Gas-Pro off, press and hold the operator button. A 4 second countdown will start. Hold the button down until the countdown has finished and the Gas-Pro will shut down. If you release the button before the countdown has finished, the Gas-Pro will resume operation.
Threshold levels can be set using Portables Pro, extending log capabilities. The data log interval is set as part of the Gas-Pro configuration and can be adjusted using Portables Pro. Event logging records significant events occurring during Gas-Pro operation.
2.9 Tank Check Mode Contents Tank Check Mode is unique to devices with a Dual-Range Flammable IR sensor fitted, or ‘Tank-Pro’ branded devices. The device should under no circumstances be used as personal protection equipment whilst in Tank Check Mode. These devices will always display Tank Check Mode after start up has completed rather than the Home Screen.
Tank Check Mode can be identified over the Home Screen as the text will be displayed in place Contents of the current user name, the tank check icon will be displayed in the bottom-right corner, and the alarms disabled icon will be displayed to the left of the tank check icon. Figure 18: Tank Check home page Prologue Set-up...
2.9.2.4 Confidence Tone Contents The Tank Check Mode confidence tone is different to other operational modes to give an audible indication of the operating mode. The Tank Check Mode confidence tone is four short ‘pips’ which are low pitch while in LEL range, and high pitch in VOL range.
Organisational specific Health and Safety regulations should be adhered to, and a number of flexible and simple solutions are available. Gas-Pro offers two types of bump test. A speedy bump test which is a gas test to the first alarm level Prologue and smart bump test, a gas test to a specified level of test gas.
Gas-Pro screen during start up. If Gas-Pro is turned off and on again within 24 hours of the gas test, the Gas-Pro will not inform the user of a need for a bump test. However on applying a magnetised flow plate, or placing Gas-Pro into the Q-Test the user will be given the option to complete a gas test (or proceed to pumped operation).
It is a fail if the detector does not go into alarm. Prologue 3.2.1.1 Procedure X Either place the Gas-Pro in a Q-Test module or attach a flow plate to the Gas-Pro. Set-up X Select Bump (see Bump/Pump functionality page 33).
3.2.3 Calibration after bump fail Contents If any channel fails speedy bump or smart bump then Gas-Pro can be configured (via Portables Pro) to perform a ‘calibration after bump fail’ immediately after the test failure. Calibration should only be performed with appropriately accurate gas.
3.4 Gas test screen flow Contents The following sequence of screen shots should be viewed with reference to the sections on ‘Speedy Bump’, ‘Smart Bump’ & ‘Calibration after bump fail‘. The screen shots show the general flow of the gas test functionality dependant upon the actual test and the decisions made.
4. Icon overview Contents The table below details the icons shown during regular operation as well as warning messages. This table is intended as a quick overview please refer to specific functional sections within this manual for further details. Icon Description Icon Description...
Ensure maintenance, service and calibration are carried out in accordance with the procedures in the manual and only by trained personnel. For further service or maintenance, contact your local Crowcon agent or regional office, for details reference the ‘Contacts’ section of the manual.
Specification 6.2 PC interface cable Troubleshooting Portables Pro allows the download and viewing of data and event logs from the Gas-Pro using an interface cable via the USB socket on a laptop or desktop computer. Appendices Please see Portables Pro instructions for details.
CH0102 Charging lead CH0103 USB communications lead (not powered) CH0104 USB communication and power lead CH0105 Gas-Pro charger cradle (no power) Prologue CH0106 Vehicle charging adaptor (use with CH0102) CH0107 5 Way multi-region power supply Set-up (Note: only for use with charging leads with serial numbers greater than Wxxxxx)
Page 46
Contents Part Number Description AC0301 1m reactive gas tubing (Tygothane® 3.2mm ID including tube insert) AC0303 3m reactive gas tubing (Tygothane® 3.2mm ID including tube insert) AC0512 Ball float probe AC0103 Calibration flow plate for PC Calibration (no magnet) Prologue Set-up Operation Gas testing...
USB interface cable USB power & communications cable 5 Way multi-region power supply * Gases not available in Gas-Pro with the internal pump option are CL , CLO & O Sensors may be degraded at the higher temperatures subject to individual sensor specifications ...
9. Troubleshooting Contents 9.1 Pump test failure In the event of a pump test failure, check the following: • Ensure a pumped flow plate was used for the test • Remove the flow plate and check the gasket for damage (scratches, tears, etc.) •...
9.2.1 Fault Descriptions Contents Fault Symtom/Error Icon Cause Action codes Message 0 or 9 Instrument won’t Flat Battery. Recharge battery. switch on. No confidence Function disabled. Reconfigure with PC beep/flash. software. 26 - 30, Gas Reading with Zero drifted. Zero the instrument in Prologue 58 - 62 no gas present.
Page 50
Display shows Battery depleted. Recharge battery. empty battery symbol during startup. Switched on and Unit full and on charge Remove Gas-Pro from fully charged. for over 12 hrs. charge. Cannot switch off. Instrument configured Move to clean air then Prologue for “No switch off in...
Contents Fault Symtom/Error Icon Cause Action codes Message Bump Test Fail The monitor has not The monitor needs Lock. been gas tested in the calibration. defined period and the gas test lock function has been activated. Battery low Battery Low (about 20 Exit the hazardous area to 30 minutes before as soon as possible and...
Propane* SS0201 0-100% LEL Butane* SS0201 0-100% LEL PC software * For Dual Range IR Gas-Pro & Tank Pro the same spare part number should be used as detailed above Accessories 10.1.4 Oxygen Sensor Part No. Range Specification SS0500 0-25% VOL (2 years)
Persistent exposure to high levels of toxic gas can shorten the life of toxic sensors. Toxic sensors may also be cross-sensitive to gases other than their specific target gas, and hence the presence of other gases may cause the sensor to respond. If unsure, contact Crowcon or your local agent. Prologue Use of high power radio transmitters in close proximity to the instrument may exceed RFI immunity levels and cause erroneous indications.
Run time is equal to the expected operating time following a full charge/discharge cycle. Operation Should the Gas-Pro completely discharge, charge within 3 days. This will maintain the internal clock. Gas testing Gas-Pro in a fully charged state will last for 3 months from new.
Warranty Contents This equipment leaves our factory fully tested and calibrated. If within the warranty period of two years from despatch, the equipment which includes pump, battery and common sensors (see sensor chart below) is proved to be defective by reason of faulty workmanship or material, we undertake at our option either to repair or replace it free of charge, subject to the conditions below.
Page 58
Crowcon spares for replacement parts (including sensors) Gas testing or has been serviced or repaired by any party not authorised and certified by Crowcon to do so. The warranty does not cover misuse or abuse of the unit including use outside of specified limits.
Page 59
Crowcon reserves the right to apply a handling and carriage charge whereby units returned as Contents faulty, are found to require only normal calibration or servicing, which the customer then declines to proceed with. For warranty and technical support enquiries please contact:...
Need help?
Do you have a question about the Gas-Pro and is the answer not in the manual?
Questions and answers