INSTRUCTIONS MANUAL PROLINE PLUS PROLINE PLUS PUMP...
Page 2
Proline Plus PUMP Proline Plus ECOLOGICAL MANUAL FLUSHING VALVE Control system for lower water Manual valve for the washing of consumption. the membrane. MANUAL FLUSHING VALVE DIRECT ACCESS Manual valve for the washing of Easy maintenance. the membrane. SOLENOID VALVE INSERT With safety filter.
Page 4
Proline Plus PUMP NUMBER REF. DESCRIPTION 205800 Filter housing 2 pieces (cap and cup) 263100 Steel reservoir tank with plastic covering 263700 1/4” ball valve for tank 206600 Filter housing wrench 767201 50 GPD membrane 272000 1/4” polythene tube 1/4” ball valve 1/4” male tube...
05.3 Operation and maintenance 05.4 Use of the system 05.5 Recommendations for the correct use of the reverse osmosis water 06. INSTALLATION OF THE SYSTEM 07. OPERATION OF THE PROLINE PLUS SYSTEMS 07.1 Description of Operation 08. MAINTENANCE AND CONSUMABLES 08.1 Maintenance 08.2 Hygienisation...
PROLINE PLUS Series system. You will perceive an improvement in the taste of your drinking The PROLINE PLUS series systems are some of the best do- water, and likewise in the taste of your coffees, juices or ice- mestic appliances for the improvement of the characteristics cubes.
(rejected water or that with high concentrations of salt) are The TFC reverse osmosis membrane of your PROLINE PLUS diverted to the drainpipe. Series system can reduce the concentration of the elements...
2. Introduction Conversion factors 2.5 The effect of the concentration of salts in the feed water BY PRESSURE CONVERSION FACTOR REJECTION OF SALTS PRESSURE (BARS)) ON PRODUCTION The concentration of salts and substances in the water to be 0.70 0.70 treated influences the capacity of the production of reverse 1.00 0.25...
**For salinity up to 2000 ppm, consult the pressure table in relation to the TDS in section 2 of the present manual. electric and electronic components (only in PROLINE PLUS See section 5 WARNINGS. PUMP models).
2.5 bars. (Ref. 577603). • There is no pump incorporated into the PROLINE PLUS series system. The installation of a system without pump is recom- mended when the system pressure is higher than 3 bars.
• The PROLINE PLUS PUMP series system needs an electrical • Special attention must be paid to the regular cleaning and socket that is at least 1 metre away.
6. Installation of the system 6. INSTALLATION OF THE SYSTEM The installation of your PROLINE PLUS reverse osmosis system must be carried out by qualified personnel from an authorised technical service. Follow the recommendations in Section 5 of this manual.
Page 13
6. Installation of the system 6. Installation of the system Once it has been decided whether to put the tap on the counter top or sink (usually in the corner), a hole is drilled in the same with the 12 mm bit, to pass the connecting pipe Image 21.
Page 14
6. Installation of the system Following this you should make the hydraulic connection of on brass threads. The two connectors (1/2” and 1/4”) must the appliance to the system. As the system is under pressure be screwed in with a monkey wrench until you are sure that the stopcock situated in the cold water outlet must be closed.
Page 15
6. Installation of the system not obstruct the hole or water flow outlet). Envisage the Make the connection of the reservoir tank and the con- space necessary for the assembly of the clamp, image nector of the machine marked “tank/depósito” using the 1/4” Next the drainpipe collar shall be assembled, but making sure tube.
Page 16
6. Installation of the system Should you wish to feed any other consumer point (tap, fridge with ice-cube dispenser, etc.) use a 1/4” plastic con- ductor Ref. 272000) and a 1/4” te (Ref. 279300) for every extra pipe connection you need. Check that the pressure of the reservoir tank is 0.5 bars (7 P.S.I.), using the portable pressure gauge and the valve that is at the bottom of the tank.
7. Operation of the PROLINE PLUS systems 7. OPERATION OF THE PROLINE PLUS SYSTEMS VALID LIST FOR PROLINE PLUS PUMP AND PROLINE PLUS Connection kit and manual valve Manual valve of reservoir tank Turbidity filter Pressurised reservoir tank Granulated Active Carbon filter (GAC)
PROLINE PLUS PUMP). The PROLINE PLUS series systems have a manual brush The PROLINE PLUS PUMP models incorporates a minimum valve or a membrane wash (7). Turn this valve the amount of pressure switch (14) that protects the pump, against falls in times indicated, following the steps described in section 9.3...
ORIGINAL PROLINE PLUS CONSUMABLES It is important for the maintenance of your system to be carried out by the official service of the PROLINE PLUS series, which will use original spare parts and offer you information, a maintenance contract and service guarantee.
8. Maintenance and consumables forcing the other components. In the case of the PROLINE Extract the membrane from inside the membrane housing, images 82 and 83 PLUS PUMP model, fix the in-let nipple with the vice grip and apply the hygienisation procedure de- pliers, to avoid it unscrewing in relation to the pressure switch, scribed in section 7 (Start-up and hygienisation).
8. Maintenance and consumables 8.3 Flushing Flush the membrane once a day to clean it of any deposits or incrustations it may have on its surface. This flushing will remove these elements and they will be eliminated down the drain. For this, after the continuous extraction of more than 2 litres of water, image...
9. Identification guide and problem resolution 9. IDENTIFICATION GUIDE AND PROBLEM RESOLUTION SYMPTOM CAUSE SOLUTION 1. Leak from tap. Turn off components worn. Substitution of tap. Joint pinched or worn. Change joints. 2. Exterior leak to the By base of tap. Check condition of tap and if necessary substitute it.
Page 23
9. Identification guide and problem resolution SYMPTOM CAUSE SOLUTION 11. The rejection never stops. Electro in-let valve dirty or deteriorated. Check if rejection stops with the reverse osmosis system unplugged. Should it not, clean or substitute. Excess feed pressure. Put in a pressure regulator. Tank has little air.
(*) must be filled in by the technician installer and transcribed by him from the INSTALLATION AND PUTTING INTO OPERATION REGISTRATION SHEET OF THE SYSTEM. PURICOM EUROPE · C. Aiguafreda 8 · Pol. Ind. l’Ametlla Park · 08480 Barcelona · SPAIN...
SHEET TO BE COMPLETED BY THE TECHNICIAN INSTALLER.SHEET FOR THE TECHNICIAN INSTALLER. SHEET REGISTERING THE INSTALLATION AND PUTTING INTO OPERATION OF THE EQUIPMENT COMMENTS NOTES FOR THE TECHNICIAN/INSTALLER: Read the present manual carefully. Should you have any doubts, please contact your distributor’s technical attention service (T.A.S.). *Results of installation and putting into operation.