CONTENTS General Information ..........................4 1.1. Purpose of this manual......................4 1.2. Composition of the manual and consultation details ............. 4 1.3. Safety signals and danger......................4 1.1. General safety precautions ..................... 5 1.2. Identification of Manufacturer and System ................5 1.3.
Use and Maintenance Manual Residential Vacuum Units >>> General Information 1. General Information Read this manual carefully before starting operations of movement, unpacking, installation, use, maintenance and decommissioning of the Residential Vacuum Units. 1.1. Purpose of this manual This installation, use and maintenance manual is an integral and essential part of the vacuum cleaner system.
Use and Maintenance Manual Residential Vacuum Units >>> General Information DANGER OF ELECTRICAL SHOCK PROHIBITED FOR PERSONS NOT SUITABLY TRAINED TO USE SYSTEM COMPULSORY TO WEAR PROTECTIVE MASK AGAINST INHALATION OF DUST AND HARMFUL SUBSTANCES COMPULSORY TO WEAR PROTECTIVE GLOVES AGAINST DUST AND HARMFUL SUBSTANCES COMPULSORY TO WEAR SAFETY FOOTWEAR COMPULSORY TO WEAR PROTECTIVE GLOVES WHILE MOVING GOODS...
Page 6
Use and Maintenance Manual Residential Vacuum Units >>> General Information Figure 1 The rating plate is on the right side of the central vacuum. For all requests for technical assistance, in addition to details of the problem encountered, customers are asked to inform the manufacturer of all system information given on the identification plate, as follows: •...
Use and Maintenance Manual Residential Vacuum Units >>> General Information MANUFACTURER Information Via del Lavoro, 8/11 info@generaldaspirazione.com 47030 – San Mauro Pascoli (FC) www.generaldaspirazione.com IMPORTANT For all requests regarding installation, use, maintenance or the supply of spare parts, customers are invited to contact the manufacturer, whose identification data can be found on the identification plates.
Use and Maintenance Manual Residential Vacuum Units >>> General Information 1.4. Recommendations for use In case of fire do not use water for switching off. Failure to observe this instruction may expose the operator to the risk of electric shock. •...
The filtered air is then expelled towards the exterior through the outlet ducts. 2.2. Technical characteristics SERIES Wireless Intelligence Total MODEL W1000 W1250 i1000 i1250 i1600 i1750 T1250 T1600 T1750 Maximum surface area (mq) Smart electronics Self-cleaning function Wireless...
Use and Maintenance Manual Residential Vacuum Units >>> Product Description 2.8. Description of user interface Figure 5 The parameters and time set by the factory can be modified and customized according to your needs, following the instructions given in chapter 5.7.2 1.
Use and Maintenance Manual Residential Vacuum Units >>> Product Description 2.9. Description of embedded user interface Figure 6 1. GREEN LED – When lit indicates the presence of a power supply, and the vacuum unit is ready for use. 2. YELLOW LED – Empty the dust container. 3.
Page 16
Use and Maintenance Manual Residential Vacuum Units >>> Product Description Figure 7...
Use and Maintenance Manual Residential Vacuum Units >>> Handing and unpacking 3. Handling and unpacking The vacuum unit is shipped in a cardboard box with appropriate reinforcements to protect it against impact during transport and delivery. We recommend that you do not remove the packaging until installation to prevent damage.
Use and Maintenance Manual Residential Vacuum Units >>> Residential Vacuum Units Installation 4. Installation This equipment is designed to be installed by suitably trained personnel and trained. ATTENTION: The entire system must be installed by qualified personnel in full compliance with standards of workmanship and with applicable standards and regulations.
Use and Maintenance Manual Residential Vacuum Units >>> Residential Vacuum Units Installation 4.2. Dimension and technical data WIRELESS INTELLIGENCE TOTAL Model W100 W1250 I1000 I1250 I1600 I1750 T1250 T1600 T1750 1041 1041 1085 1186 1186 Height (mm) Diameter (mm) A – Minimun (mm)
Page 20
Use and Maintenance Manual Residential Vacuum Units >>> Residential Vacuum Units Installation Figure 8 Figure 9 4.Fit the main vacuum unit, inserting the rectangular projections frontally into the corresponding recesses in the wall bracket, and applying pressure until they click in. (Figure 10). 5.
Page 21
Use and Maintenance Manual Residential Vacuum Units >>> Residential Vacuum Units Installation CAUTION: Electrical connections must be made only by qualified personnel. 7. Connect the two coloured poles (black, red) of the 7x0.25 cable to the two wires of the 5 Vdc low- voltage command of the INLETS LINE.
Use and Maintenance Manual Residential Vacuum Units >>> Residential Vacuum Units Installation 4.4 Reversibility of suction and outlet connections Main vacuum units are normally supplied with connections for air inlet and outlet pipes on the right. If necessary, this direction can be modified by independently moving the air inlet and outlet connections to the left.
Use and Maintenance Manual Residential Vacuum Units >>> Residential Vacuum Units Installation Final system trial The final system trial is the first proof of guarantee for GENERAL D’ASPIRAZIONE users. While building work is still in progress, before floors are laid, the system is already capable of operating. At this stage it is possible therefore to check the satisfactory operation of the system, and to make any corrections if necessary.
Use and Maintenance Manual Residential Vacuum Units >>> Use of main vacuum unit 5. Use of main vacuum unit Important The system is designed for use by one operator only. For motives of efficiency only one suction point may be used (open) at a time. Important Before starting to use the system check that all system components are in place.
Use and Maintenance Manual Residential Vacuum Units >>> Use of main vacuum unit 5.2 Use of the plant Once you start the control panel can be used according to the directions back to Chapter 1.6 "Recommendations for Use." To use the system need to connect the working tube, consisting of the sleeve, the hose and the Brava Wireless Handle from one side and from the telescopic extension and the brushes or the various other accessories.
Use and Maintenance Manual Residential Vacuum Units >>> Use of main vacuum unit Important: During the self-cleaning cycle do not open the dust collector container and after the end of the cycle wait at least a minute before opening it Make annual inspections on the filter to ensure that it is undamaged and to check if it needs washing (if washed, the filter must be dry before being replaced).
Page 27
Use and Maintenance Manual Residential Vacuum Units >>> Use of main vacuum unit Important: When cleaning the filter does not use the unit. 5.6.2. Alarms Signals Thermal protection alarm *** Wait for automatic reset *** In the case of a possible use of the plant obstructed or dirty filter, a thermal switch of protection stops the operation of the control unit to prevent overheating that could damage it.
This procedure is used to modify the parameter that controls alarm operation, set by default at 5 hours on models W1000 and i1000, and at 10 hours for models W1250, i1250, i1600, i1750, T1250, T1600 and T1250. Enter the USER MENU by pressing the SET button when the display shows the STANDBY message.
Page 29
Use and Maintenance Manual Residential Vacuum Units >>> Use of main vacuum unit Scroll through the USER MENU with the UP and DOWN keys until you reach the EMPTY CONTAINER submenu. Press the SET button and then use the UP and DOWN keys to enter the desired value. To memorize the new value entered, keep the SET button pressed down for a few seconds until the MEMORIZED message appears.
Use and Maintenance Manual Residential Vacuum Units >>> Maintenance 6. Maintenance ATTENTION: Before carrying out any maintenance operations it is compulsory to unplug the unit from the 230 V power supply wall socket and to put on protective gloves and a facemask.
Use and Maintenance Manual Residential Vacuum Units >>> Maintenance 5. Check the condition of the filter cartridge, and clean and wash it if necessary (chap. 6.2). 6. Replace the dust container in the side hooks of the handle, and close it with a slight pressure of both hands (D) to the sides of the central button.
Page 32
Use and Maintenance Manual Residential Vacuum Units >>> Maintenance · Never use the main vacuum unit without the filter. · The washed filter must be completely dry before being refitted. · Do not throw the inverted red cone away – replace it correctly above the dust container.
Use and Maintenance Manual Residential Vacuum Units >>> Safety Components 7. Safety Compontents 7.1 Protection Fuse All main vacuum units are protected by a fuse that interrupts the power supply to the motor in case of malfunctions or electrical problems. To replace the fuse, unscrew the fuse-holder located above the power supply cable (see Fig.
Use and Maintenance Manual Residential Vacuum Units >>> Inconveniences causes and solution 8. Inconveniences causes and solution The main vacuum unit does not work… • Check the 230 V power supply. • If using the Wireless system, check that the transmitter indicator light goes on when the button is pressed, otherwise check the batteries and replace if necessary.
Use and Maintenance Manual Residential Vacuum Units >>> Inconveniences causes and solution Suction power is very low… Check that… • The other suction points are closed • There are no foreign bodies trapped in the brush, flexible hose or curved joint •...
Use and Maintenance Manual Residential Vacuum Units >>> Decommissioning and disposal Decommissioning and disposal When the device has terminated its cycle of use and must be decommissioned, follow these instructions to protect the environment: The presence of this symbol on the product or on the pack indicates that the product must not be treated as normal household refuse, but must be taken to a suitable collection centre for the recycling of electrical and electronic devices.
The centralized vacuum cleaner systems for civilian purposes GDA Series: 3. Wireless – Models W1000 and W1250 4. Intelligence – Models i1000, i1250, i1600 and i1750 5. Top – Models T1250, T1600 and T1750 are designed and manufactured in compliance with the following regulations and directives: •...
Page 38
Company with Certified Quality System UNI EN ISO 9001:2008 General D’Aspirazione via del Lavoro, 9 47035 San Mauro Pascoli (FC) Tel. 0541.93.10.12 Fax. 0541.933763 info@generaldaspirazione.com www.generaldaspirazione.com...
Need help?
Do you have a question about the i1250 and is the answer not in the manual?