Advertisement

Installation and
Operation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Zodiac FLOPRO SS

  • Page 1 Installation and Operation Manual...
  • Page 2: Table Of Contents

    ZODIAC FloPro ssPump installation & Operation Manual Contents Section 1: Important Safety Instructions 1.1. Safety Instructions 1.2. Pool Pump Suction Entrapment - Prevention Guidelines Section 2: General Description 2.1. Introduction 2.2. Description Section 3: Installation 3.1. Plumbing 3.1.1. Preparation 3.1.2. Pump Location 3.1.3 .
  • Page 3: Section 1: Important Safety Instructions

    ZODIAC FloPro ssPump installation & Operation Manual Section 1. Important Safety Instructions EQUIPMENT INFORMATION RECORD READ AND FOLLOW ALL INSTRUCTIONS DATE OF INSTALLATION ............................ 1.1 Safety Instructions All electrical work must be performed by a licensed electrician and conform to all national, INSTALLER INFORMATION ..........................
  • Page 4: Pool Pump Suction Entrapment Prevention Guidelines

    NOTE: If more than 10 suction fittings are needed, the pipe size must be increased. 7. Zodiac Pool Care SA (Pty) Ltd recommends that 50mm (outer diameter) pipe is used for 3.1.2 Pump Location suction and discharge.
  • Page 5: Section 4: Operation

    8. For technical assistance, call Zodiac Technical Support at 0860 887 665. Zodiac Pool Care SA (Pty) Ltd strongly recommends that you call a qualified service Trapped air in the system can cause the filter lid to be blown off, which can result technician to perform any repairs on the filter/pump system.
  • Page 6: Troubleshooting

    1. Turn off the pump. Switch off the circuit breaker to the pump motor. If you are not provider. replacing the motor, do not disconnect the electrical wiring. NOTE: If you are replacing the motor, Zodiac strongly recommends that a qualified service technician or electrician properly disconnect the electrical wiring at the pump motor.
  • Page 7: Impeller Replacement

    ZODIAC FloPro ssPump installation & Operation Manual 2. Turn off any valves to prevent pool water from reaching the pump. Drain the water from the pump by loosening the unions or removing the drain plugs. 3. Using a 14mm wrench, loosen the bolts connecting the pump body to the motor backplate.
  • Page 8: Mechanical Seal Replacement

    ZODIAC FloPro ssPump installation & Operation Manual . Slide the diffuser into the mating hole in the pump body to connect the pump body to the backplate. While supporting the motor, start two (2) screws on opposite sides. (This will hold the motor in position while you start the other screws.) Start the other four (4) screws.
  • Page 9: Motor Replacement

    6. To reassemble the pump after replacing the motor, follow steps 1 through 14 of Section 6.2.3, Impeller Replacement. NOTE: Zodiac recommends replacing the mechanical seal at the same time that you replace the motor. See Section 6.2.4, Mechanical Seal Replacement, for details.
  • Page 10: Physical And Operational Specifications

    7.2 Performance curves Motor -kW 0.8kW 1.0kW 1.4kW Motor -Voltage (Alternating Current) V230 AC V230 AC V230 AC Zodiac FloPro ssPump - Head vs Flow Rate and Frequency (Hertz) Hz50 Hz50 Hz50 Motor -Amps Maximum Amax 3.6A 4.6A 6.2A Motor -Revolutions Per Minute RPM...
  • Page 11 ZODIAC CUSTOMER CARE CENTRE Zodiac Group South Africa Customer care line: 0860 887 665 Email: customer.care@zodiac.com www.zodiac.co.za...

Table of Contents