NI 9223 Getting Started Manual

NI 9223 Getting Started Manual

4 ai, ±10 v, 16 bit, 1 ms/s/ch simultaneous

Advertisement

GETTING STARTED GUIDE
NI 9223
4 AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9223 and is the answer not in the manual?

Questions and answers

Summary of Contents for NI 9223

  • Page 1 GETTING STARTED GUIDE NI 9223 4 AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous...
  • Page 2: Safety Guidelines

    This document explains how to connect to the NI 9223. Before you begin, complete the software and Note hardware installation procedures in your chassis documentation. The guidelines in this document are specific to Note the NI 9223. The other components in the system might not meet the same safety ratings.
  • Page 3: Safety Voltages

    MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary NI 9223 Getting Started Guide | © National Instruments | 3...
  • Page 4: Safety Guidelines For Hazardous Locations

    CAT III, or CAT IV. Safety Guidelines for Hazardous Locations The NI 9223 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous locations; and nonhazardous locations only.
  • Page 5 Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9223 with screw terminal has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO Certificate No. 07 ATEX 0626664X and is IECEx UL 14.0089X certified. The NI 9223 with BNC has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO Certificate No.
  • Page 6: Electromagnetic Compatibility Guidelines

    -40 °C ≤ Ta ≤ 70 °C. If you are using the NI 9223 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.
  • Page 7 Electrostatic Discharge (ESD) can damage Caution the NI 9223 with screw terminal. To prevent damage, use industry-standard ESD prevention measures during installation, maintenance, and operation. NI 9223 Getting Started Guide | © National Instruments | 7...
  • Page 8: Cable Requirements For Emc Compliance

    I/O cables must be no longer than 30 m (100 ft). Cable Requirements for EMC Compliance Select and install cables for the NI 9223 with screw terminal in accordance with the following requirements: • Connect the cable shield to the chassis ground (grounding screw of the chassis) using the shortest length of wire possible.
  • Page 9 Figure 1. Cable Connections for NI 9223 with screw terminal for EMC Compliance Shield AI0+ Signal AI0– Source Shield AI1+ Signal AI1– Source Shield AI2+ Signal AI2– Source Shield AI3+ Signal AI3– Source NI 9223 NI 9223 Getting Started Guide | © National Instruments | 9...
  • Page 10: Special Conditions For Marine Applications

    In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. 10 | ni.com | NI 9223 Getting Started Guide...
  • Page 11: Preparing The Environment

    Preparing the Environment Ensure that the environment in which you are using the NI 9223 meets the following specifications. Operating temperature -40 °C to 70 °C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity 10% RH to 90% RH, (IEC 60068-2-78) noncondensing...
  • Page 12 NI 9223 Pinout AI0+ AI0+ AI0– AI0- AI1+ AI1+ AI1– AI1- AI2+ AI2+ AI2– AI2- AI3+ AI3+ AI3– AI3- 12 | ni.com | NI 9223 Getting Started Guide...
  • Page 13: Grounded Connections

    Grounded Connections Signal Source – AI– NI 9223 Make sure the voltage on the AI+ and AI- connections are in the channel-to-earth safety voltage range to ensure proper operation. NI 9223 Getting Started Guide | © National Instruments | 13...
  • Page 14: Floating Connections

    AI– NI 9223 NI 9223 Connection Guidelines • Make sure that devices you connect to the NI 9223 are compatible with the module specifications. • You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9223 with screw terminal.
  • Page 15: Wiring For High-Vibration Applications

    Use the NI 9971 backshell kit. Overvoltage Protection The NI 9223 provides overvoltage protection for each channel. Refer to the device datasheet on ni.com/manuals Note for more information about overvoltage protection. NI 9223 Getting Started Guide | © National Instruments | 15...
  • Page 16: Where To Go Next

    NI 9223 Datasheet NI 9223 Datasheet NI-RIO Help NI-DAQmx Help LabVIEW FPGA Help LabVIEW Help RELATED INFORMATION C Series Documentation Services ni.com/services & Resources ni.com/info cseriesdoc Located at ni.com/manuals Installs with the software 16 | ni.com | NI 9223 Getting Started Guide...
  • Page 17: Worldwide Support And Services

    You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI 9223 Getting Started Guide | © National Instruments | 17...
  • Page 18 National Instruments Patent Notice at . You can find information about end-user ni.com/patents license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at for the NI ni.com/legal/export-compliance global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/ export data.

Table of Contents