Loading and integrating a configuration (PC systems)
11.3 Integrating Runtime in SINUMERIK Operate (PC systems)
Procedure
To integrate the Runtime in SINUMERIK Operate, follow these steps:
1. On the PC system (e.g. PCU 50.5), click in the Windows Start menu on "Start >
Siemens Automation > SINUMERIK > Integration Sinumerik Operate English Tool".
The "Integration SINUMERIK Operate" dialog opens.
Figure 11-1
2. Make the required settings:
146
Example of a completed "Integration SINUMERIK Operate" dialog
No
Array
Definition/Action
.
①
Softkey position
The drop-down list shows the currently free, assignable horizontal soft-
keys. Select an available softkey (default softkey = 7).
②
Project file
The TIA Portal configuration file of the WinCC RT Advanced can be en-
tered by means of the input box. The configuration file is displayed with
the "Browse" button.
The path to the "pdata.fwc"project file may not contain any spaces.
③
WinCC RT as
Here you specify if the WinCC Runtime application covers up
power up appli-
SINUMERIK Operate when it starts up.
cation
•
•
NO: SINUMERIK Operate is not covered.
YES: SINUMERIK Operate is covered.
SINUMERIK Integrate Create MyHMI / WinCC V13 SP1
Configuration Manual, 11/2014