<parameter>=<value>
Values
riris=<float>
-999 - 999
focusrel=<string>
far,
farmore,
near,
nearmore
irisrel=<string>
open,
close,
openmore,
closemore
zoomrel=<string>
tele,
wide
auxiliary=<string>
<function
name>
setserverpresetname=
<preset
<string>
name>
gotoserverpresetname=
<preset
<string>
name>
speed=<int>
1 - 999
Example: Move camera 1 to home position
http://myserver/cgi-bin/
control?camera=1&move=home
Example: Move HSR camera 12 to a preset position
named 'door'
http://myserver/cgi-bin/
control?port=2&hsrcamera=12&gotopresetpos=door
Note: If "gotoserverpresetname=" is used in the
request, all the other parameters will be ignored except
"port=" and "camera=".
Description
Moves iris. Positive values means
iris open and negative values means
iris close. Only used for Kalatel.
Adjusts the focus gradually. Only
used for Kalatel.
Adjusts the iris gradually. Only
used for Kalatel.
Adjusts the zoom gradually.
Activates/deactivates auxiliary
functions of the device where
<function name> is the name of the
device specific function. Only used
for Kalatel.
Associates the current position to
<preset name> as a preset position
in the server.
Move to the position associated
with the <preset name>.
Sets the head speed of the device
connected to the specified camera.
Not used for Kalatel.
z Controlling and Monitoring
(Relay, 4 digital inputs)
Method: GET/POST
Syntax: input
http://< servername >/cgi-bin/io/
input.cgi?< parameter >=< value >[&< parameter >=
< value >...]
Syntax: output
http://< servername >/axis-cgi/io/
output.cgi?< parameter >=< value >[&< parameter >=
< value >...]
with the following parameters and values
<parameter>=<value>
Values
check=<int>[,<int>, ...]
<id1>
[,<id2>, ...]
action=<string>
1:[<a>]
[<wait><a>
...]
monitor=<int>[,<int>,...]
<id1>
[,<id2>, ...]
Return: "monitor", i.e., multipart "check" parameter
HTTP/1.0 200 OK\r\n
Content-Type:
replace;boundary=< boundary >\r\n
\r\n --< boundary >\r\n < monitor data >
where the proposed boundary <boundary> is
ioboundary and the <monitor data> part is
Content-Type: text/plain\r\n
\r\n
< check data >--< boundary >\r\n
and < check data > is
IO< n >:< action char >\r\n
and <n> is the IO port number and <action char> is
the action character described in the table above.
Note: The output can contain extra blank lines, i.e.,
extra \r\n within the sections.
Description
Returns the status of one or more
inputs numbered id1 ,id2, ....
Sets the output relay on or off and
waits <wait> milliseconds.
<a> = Action character: / or \ / =
on, \ = off.
<wait> = Delay in milliseconds.
Returns a multipart stream of
"check" outputs (see return
description below).