Configure Upm Ports As Ethernet Pass-Through (Optional); View The Current Configuration; Configure Port Group 0 As Ethernet Pass-Through - Dell S5000 Configuration Manual

Data center switch
Hide thumbs Also See for S5000:
Table of Contents

Advertisement

5

Configure UPM ports as Ethernet Pass-through (Optional)

The FC ports on the Unified Port Module (UPM) can be configured as Ethernet Pass-Through. The 12 ports
are divided into six port groups numbered 0-5. Two ports in each port group can be configured separately
as FC or Ethernet Pass-through.
Note: This operation requires a reload for the changes to take effect.
5.1

View the current configuration

Use this command to view the current mode of the ports and also the port group mapping.
FTOS#
show system
PortGroupId
0
1
2
3
4
5
5.2

Configure port group 0 as Ethernet Pass-through

FTOS(conf)# stack-unit 0 port-group 0 portmode Ethernet
Changing port mode on slot 0 port-group 0 will make interface configs of 0 and 1
obsolete after a save and reload.
[confirm yes/no]:yes
Please save and reload for the changes to take effect.
Note: Save and reload is required.
15
SCG1007
Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs
stack-unit
0 port-group portmode
Ports
Mode(Curr Boot) Mode(Next Boot)
0,1
FC
2,3
FC
4,5
FC
6,7
FC
8,9
FC
10,11
FC
FC
FC
FC
FC
FC
FC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents