Some other examples of the log are as follows:
1)
E202 Sun,01Apr 03:41:45
Disarmed by User
Area 1 Name
Ur1 User 1 Name
E202 Dest= SLL-----
Kp1 Keypad 1 Name
Panel 1
Dest 1 at 01-Apr 03:41:57
2)
E405 Sun,01Apr 06:41:45
Burglary Zone Bypassed
Area 1 Name
Zn3 Zone 3 Name
E405 Dest= SLL-----
Ur1 User 1 Name
Panel 1
Dest 1 at 01-Apr 06:41:57
The Dest= field displays the various reporting route
information for up to eight different reporting
destinations. Your installer will have configured these
during installation.
The following letters will be displayed in the eight
destination locations indicating the status of the report.
The log will also show the actual time a report was sent.
Dest =
S = Sent
L = Logged
P = Pending
F = Failed
A = Aborted
11-4
System Programming
System > Commands >

Domestic Default

This command will configure the control panel for
Domestic
format reporting (eg. mobile telephones
etc). All alarm restore reports and open/close reporting
options will be automatically disabled. Therefore, only
emergency, burglary and fire reports will be sent.
The following table list the changes that will occur when
you select domestic default using MENU 7-0-3.
Program Option
All Trouble Reports
All Bypass Reports
All Restore Reports
Destination 1 TX Format
Access Route
Open / Close Reports
Test Route
System Route
Table 33: Domestic Default Settings
1) Press [MENU] + [7] + [0] + [3]. The keypad will
display:
To RECONFIGURE all panel
dialler programming to
DOMESTIC, Press OK. or To
Cancel,Press MENU.
2) Press [OK] to start the default process or press
[MENU] to cancel and exit.
3) The keypad will display the following message
during the default process and will exit back to the
menu when finished.
Defaulting System
..Please Wait..
System > Commands >
Factory Default
This command will erase ALL programmable data and
return the control panel to factory default settings.
Defaulting the panel will NOT erase any history events
that are currently stored in the panel.
i
During a factory default both the Status and Dialler
LED indicators on the panel will flash very quickly to
Note
indicate defaulting is still in progress.
1) Press [MENU] + [7] + [0] + [4]. The keypad will
display:
MENU 7-0-3
Domestic Default Value
Disabled
Disabled
Disabled
Domestic Reporting
Log Only
Log Only
Log Only
Log Only
MENU 7-0-4