  • Page 1 AMP SERIES AMP SERIES HEAVY DUTY POWER AMPLIFIER HEAVY DUTY POWER AMPLIFIER CODE: 277.328...
  • Page 2: Important Safety Instructions

    The lightning flash with arrowhead symbol within an CAUTION equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the RISK OF ELETRIC SHOCK product's enclosure, that may be of sufficient DO NOT OPEN magnitude to constitute a risk of electric shock to persons.
  • Page 3: Table Of Contents

    AMP SERIES Indice PROTECT LEDs ..........7 LIMIT LEDs .
  • Page 4 Il comodo display a LEDs consente una chiara visione dello ‘status’ degli amplificatori in qualsiasi condizione di illuminazione. Gli AMP SERIES sono adatti a tutti i tipi di utilizzo in cui si richiedano amplificatori potenti, versatili ed affidabili, con dimensioni compatte ed un ottimo rapporto prezzo/prestazioni: dai sistemi di amplificazione da trasporto alle installazioni fisse, dai sistemi di multi- amplificazione ai setups casalinghi.
  • Page 5 AMP SERIES Norme di installazione ed uso Prima di collegare l’amplificatore alla presa di corrente, accertatevi che la tensione di rete corrisponda a quella indicata sul retro dell’apparato (è accettata una tolleranza fino a ±10%). Prima di collegare il cavo di alimentazione alla presa di rete, accertatevi sempre che questo non sia danneggiato o addirittura con fili scoperti.
  • Page 6 AMP SERIES Norme di installazione ed uso E’ buona norma, per non compromettere il corretto funzionamento del’amplificatore, evitare di posizionarlo per tempi troppo prolungati in luoghi esposti all’azione di agenti atmosferici (umidità, temperature molto elevate, ecc.), all’accumulo di polvere e a vibrazioni troppo intense.
  • Page 7 AMP SERIES Funzioni & controlli AMP 2.4 PHONES POWER PROTECT PROTECT CLIP CLIP -0 0 -0 0 CHANNEL 1 SIGNAL CHANNEL 2 SIGNAL HEAVY DUTY POWER AMPLIFIER HEAVY DUTY POWER AMPLIFIER AMP 4 PROTECT LIMIT SIGNAL CH 1 PROTECT LIMIT...
  • Page 8 AMP SERIES Funzioni & controlli AMPLIFIER OUTPUTS AMPLIFIER INPUTS 100V 50/60Hz AMP 2.4 "WARNING" 120V 50/60Hz TO REDUCE THE RISK OF 230V 50/60Hz CH 2 CH 1 CH 2 CH 1 FIRE OR ELECTRIC SHOCK DO NOT EXPOSE MIN. LOAD 240V 50/60Hz THIS PRODUCT TO RAIN OR MOISTURE.
  • Page 9 AMP SERIES Funzioni & controlli Indicatori di intervento delle protezioni. L’eventuale accensione di questi LEDs segnala l’attivazione di una delle protezioni che salvaguardano le diverse sezioni dell’amplificatore (ed eventualmente anche i diffusori) in caso di condizione anomala di funzionamento. In questi casi, l’erogazione della potenza viene normalmente sospesa fino al...
  • Page 10 Prese d'aria del sistema di raffreddamento dell'amplificatore. La ventola del sistema di raffreddamento degli amplificatori AMP SERIES crea un flusso d'aria con scorrimento in direzione davanti/dietro: ciò significa che l'aria viene prelevata dall'apertura posta sul fronte e, dopo aver raffreddato i dissipatori ed il trasformatore di rete, viene espulsa attraverso l'apertura posta sul retro.
  • Page 11 AMP SERIES Funzioni & controlli Collegate alle uscite dell'amplificatore solo diffusori (o sistemi di diffusori) che rientrino nei limiti di carico di potenza e di impedenza dichiarati per l’amplificatore stesso (vedi ê Specifiche tecniche). Usate solo cavi per diffusori (cavi o piattine a 2 fili, solitamente 1 rosso e 1 nero): non usate mai cavi schermati o “cavi segnale”...
  • Page 12 AMP SERIES Funzioni & controlli viceversa, un segnale collegato all’ingresso B viene amplificato solo dal canale B e inviato alla sola uscita B. SPEAKERS STEREO STEREO BRIDGE PARALLEL MIXER AMPLIFIER OUTPUTS AMPLIFIER INPUTS CH 2 CH 1 BRIDGED 8 Ohm...
  • Page 13 AMP SERIES Funzioni & controlli Con la predisposizione PARALLEL un solo segnale viene amplificato da entrambi i canali A e B dell’amplificatore. In altre parole, un segnale collegato all’ingresso A viene inviato sia all’uscita A che all’uscita B. SPEAKERS PARALLEL...
  • Page 14 AMP SERIES Funzioni & controlli SPEAKERS SIGNAL LINK AMPLIFIER OUTPUTS AMPLIFIER INPUTS CH 2 CH 1 BRIDGED 8 Ohm CH 2 CH 1 CH 2 CH 1 MIN 4 Ohm MIN 4 Ohm MIXER LIMITER STEREO GROUND FLOATING PARALLEL BRIDGE...
  • Page 15 AMP SERIES Cavi di collegamento Di seguito sono riportati gli schemi di connessione dei connettori utilizzabili con gli amplificatori . Per il collegamento dell’amplificatore al mixer accertatevi di utilizzare (cavi schermati, costituiti da due fili più una calza che funge da schermo) e (cavi colonna costituiti solo da due fili, in genere di sezione maggiore): l’utilizzo di cavi non schermati, infatti,...
  • Page 16: Specifiche Tecniche

    AMP SERIES Specifiche tecniche 2 Ohms 300 W 550 W 1000 W 4 Ohms 230 W 425 W 650 W 8 Ohms 120 W 150 W 270 W 400 W 4 Ohms bridged 540 W 1100 W 2000 W 8 Ohms bridged...
  • Page 17 AMP SERIES Contents Contents Introduction ........2 Installation &...
  • Page 18: Introduction

    The LEDs display gives precise information on the current status of the signal in any lighting condition. The AMP SERIES is suitable to all the kinds of use in which powerful, versatile and reliable amplifiers are required, with compact dimensions and an better price/performance ratio: from the systems of movable amplification to the fixed installations, from the systems of multi- amplification to the homes setups.
  • Page 19: Installation & Operating Instructions

    AMP SERIES Installation & operating instructions Installation & operating instructions Mains Power Connection. Before connecting the amplifier to the mains power socket, make certain that the voltage corresponds with that indicated on the rear of the unit (an allowance of ±10% is acceptable).
  • Page 20 AMP SERIES Installation & operating instructions Protection and maintenance. Avoid exposing the amplifier to direct sun, strong heat, intense vibrations, very dusty or damp surroundings, or even worse, rain: this will avoid eventual malfunction, deterioration or even electric shocks and fires.
  • Page 21: Functions & Controls

    AMP SERIES Functions & controls Functions & controls AMP 2.4 PHONES POWER PROTECT PROTECT CLIP CLIP -0 0 -0 0 CHANNEL 1 SIGNAL CHANNEL 2 SIGNAL HEAVY DUTY POWER AMPLIFIER HEAVY DUTY POWER AMPLIFIER AMP 4 PROTECT LIMIT SIGNAL CH 1...
  • Page 22 AMP SERIES Functions & controls AMPLIFIER OUTPUTS AMPLIFIER INPUTS 100V 50/60Hz AMP 2.4 "WARNING" 120V 50/60Hz TO REDUCE THE RISK OF 230V 50/60Hz CH 2 CH 1 CH 2 CH 1 FIRE OR ELECTRIC SHOCK DO NOT EXPOSE MIN. LOAD 240V 50/60Hz THIS PRODUCT TO RAIN OR MOISTURE.
  • Page 23: Protect Leds

    AMP SERIES Functions & controls PROTECT LEDs Protection pilot lights. If these LEDs light up, this indicates that one of the various protections safeguarding the different sections of the amplifier and the loudspeaker enclosures has tripped due to an operating fault.
  • Page 24: Phones

    AIR VENTS (AMP 4,8 & 12) Amplifier cooling system air vents. The fan of the AMP SERIES cooling system create a flow of air with front-to-back direction: this means that the air is taken from the opening on the front and, after having cooled the heat sinks and mains transformer, is expelled through the opening on the back side.
  • Page 25: Gnd

    AMP SERIES Functions & controls Auxiliary connector for the earth of the amplifier. GROUND ON / FLOATING Controls the separation of the electrical earth from that of the chassis. Using this selector, it is often possible to break earth loops which can form when several units are connected together...
  • Page 26 AMP SERIES Functions & controls In other words, a signal connected to input A is only treated by channel A of the amplifier and only fed to output A and a signal connected to input B is only treated by channel B of the amplifier and only fed to output B.
  • Page 27: Inputs

    AMP SERIES Functions & controls With the PARALLEL setting, one signal is treated by both channel A and B of the amplifier. In other words a signal connected to input A is sent to both output A and output B.
  • Page 28: Connector Cables

    AMP SERIES Connector cables Connector cables The following diagrams illustrate the wiring of the various types of sockets that can be used with the AMP SERIES power amplifiers. To connect the amplifier to the mixer, always make certain to use only signal cables (screened cables...
  • Page 29: Technical Specifications

    AMP SERIES Technical specifications AMP SERIES • TECHNICAL SPECIFICATIONS POWER SPECIFICATIONS AMP 2.4 AMP 4 AMP 8 AMP 12 EIA output power 2 Ohms 300 W 550 W 1000 W 4 Ohms 230 W 425 W 650 W 1kHz 8 Ohms...
  • Page 30 FEDERAL COMMUNICATIONS COMMISSION NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.