6
PROGRAMMING YOUR THERMOSTAT
CONTINUED FROM SIXTH PAGE
9. Repeat steps 4 through 8 to complete weekend heating
programming.
10. When you have completed entering your heating program,
press RUN.
Enter Cooling Program
If the outside temperature is below 50 F, disconnect power to
the cooling system before programming. Energizing the air
conditioner compressor during cold weather may cause
personal injury or property damage.
1. Move SYSTEM switch to COOL position.
2. Follow the procedure for entering your heating program, using
your selected cooling times and temperatures.
7
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
20 to 30 VAC 50/60 Hz.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
8
TROUBLESHOOTING
Reset Operation
If a voltage spike or static discharge blanks out the display or
causes erratic thermostat operation you can reset the thermostat
by pressing
,
and TIME at the same time. This also
resets the factory defaults. If the thermostat has power, has been
S
y
m
p
o t
m
No Heat/No Cool/No Fan
(common problems)
No Heat
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y
P
o
s s
b i
e l
C
a
1. Blown fuse or tripped circuit breaker.
2. Furnace power switch to OFF.
3. Furnace blower compartment door or
panel loose or not properly installed.
. 1
P
o l i
i l t
h g
n t
t o
2. System Switch not set to HEAT.
3. Loose connection to thermostat or system.
4. Furnace Lock-Out Condition. Heat may also
e b
t n i
r e
i m
e t t
c l i m a t e m a s t e r . c o m
Check Your Programming
Follow these steps to check your thermostat programming one
final time before beginning thermostat operation.
1. Move SYSTEM switch to HEAT position.
2. Press PRGM to view the 1st weekday heating period time and
temperature. Each time you press PRGM, the next heating
period time and temperature will be displayed in sequence for
weekday, then weekend program periods (you may change
any time or temperature during this procedure).
3. Press RUN.
4. Move SYSTEM switch to COOL position.
5. Repeat step 2 to check cooling temperatures.
6. Press RUN to begin program operation.
YOUR THERMOSTAT IS NOW COMPLETELY PROGRAMMED
AND READY TO AUTOMATICALLY PROVIDE MAXIMUM
COMFORT AND EFFICIENCY!
THERMAL DATA
Setpoint Temperature Range:
45 F to 90 F (7 C to 32 C)
Operating Ambient Temperature Range:
32 F to 105 F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-40 F to 150 F
reset and still does not function correctly contact your heating/
cooling service person or place of purchase.
Batteries
For optimum performance, we recommend replacing batteries
once a year with fresh "AAA" Energizer
u
e s
. t i l
. t n
ATP21W02
C r e a t e d : 2 1 N o v e m b e r, 2 0 1 4
alkaline batteries.
®
C
o
r r
c e
i t
e v
A
t c
o i
n
Replace fuse or reset breaker.
Turn switch to ON.
Replace door panel in proper position to engage
safety interlock or door switch.
R
- e
g i l
t h
l i p
. t o
Set System Switch to HEAT and raise setpoint
above room temperature.
Verify thermostat and system wires are securely
attached.
Many furnaces have safety devices that shut
o d
w
n
w
h
n e
a
o l
k c
o -
t u
o c
d n
i t i
n o
c o
heat works intermittently contact the furnace
manufacturer or local service person for
assistance.