Mapping Table - Siemens SINAMICS V20 Operating Instructions Manual

Hide thumbs Also See for SINAMICS V20:
Table of Contents

Advertisement

Communicating with the PLC
6.2 MODBUS communication

Mapping table

The SINAMICS V20 inverter supports two sets of registers (40001 to 40062, 40100 to
40522) as the table below shows. "R", "W", "R/W" in the column Access stand for read, write,
read/write.
HSW (speed setpoint), HIW (actual speed), STW (control word), ZSW (status word) refer to
control data. For more information, see parameters r2018 and P2019 in Chapter "Parameter
list (Page 147)".
Register No.
Inverter
MODBUS
0
40001
1
40002
2
40003
3
40004
4
40005
5
40006
6
40007
7
40008
8
40009
9
40010
10
40011
11
40012
12
40013
13
40014
14
40015
15
40016
16
40017
17
40018
18
40019
19
40020
20
40021
21
40022
22
40023
23
40024
24
40025
25
40026
26
40027
27
40028
28
40029
29
40030
30
40031
31
40032
32
40033
142
Description
Ac-
cess
WDOG TIME
R/W
WDOG ACTION
R/W
FREQ REF
R/W
RUN ENABLE
R/W
CMD FWD REV
R/W
CMD START
R/W
FAULT ACK
R/W
PID SETP REF
R/W
ENABLE PID
R/W
CURRENT LMT
R/W
ACCEL TIME
R/W
DECEL TIME
R/W
(Reserved)
DIGITAL OUT 1
R/W
DIGITAL OUT 2
R/W
REF FREQ
R/W
PID UP LMT
R/W
PID LO LMT
R/W
P GAIN
R/W
I GAIN
R/W
D GAIN
R/W
FEEDBK GAIN
R/W
LOW PASS
R/W
FREQ OUTPUT
R
SPEED
R
CURRENT
R
TORQUE
R
ACTUAL PWR
R
TOTAL KWH
R
DC BUS VOLTS
R
REFERENCE
R
RATED PWR
R
OUTPUT VOLTS
R
Unit
Scaling
Range or On/Off
factor
text
ms
1
0 - 65535
-
1
-
%
100
0.00 - 100.00
-
1
0 - 1
-
1
0 - 1
-
1
0 - 1
-
1
0 - 1
%
100
-200.0 - 200.0
-
1
0 - 1
%
10
10.0 - 400.0
s
100
0.00 - 650.0
s
100
0.00 - 650.0
-
1
HIGH
-
1
HIGH
Hz
100
1.00 - 550.00
%
100
-200.0 - 200.0
%
100
-200.0 - 200.0
-
1000
0.000 - 65.000
s
1
0 - 60
-
1
0 - 60
%
100
0.00 - 500.00
-
100
0.00 - 60.00
Hz
100
-327.68 - 327.67
RPM 1
-16250 - 16250
A
100
0 - 163.83
Nm
100
-325.00 - 325.00
kW
100
0 - 327.67
kWh
1
0 - 32767
V
1
0 - 32767
Hz
100
-327.68 - 327.67
kW
100
0 - 327.67
V
1
0 - 32767
Read
Write
-
-
-
-
HSW
HSW
STW:3
STW:3
STW:11
STW:11
STW:0
STW:0
STW:7
STW:7
P2240
P2240
r0055.8
(BICO) P2200
P0640
P0640
P1120
P1120
P1121
P1121
LOW
r0747.0
(BICO) P0731
LOW
r0747.1
(BICO) P0732
P2000
P2000
P2291
P2291
P2292
P2292
P2280
P2280
P2285
P2285
P2274
P2274
P2269
P2269
P2265
P2265
r0024
r0024
r0022
r0022
r0027
r0027
r0031
r0031
r0032
r0032
r0039
r0039
r0026
r0026
r0020
r0020
r0206
r0206
r0025
r0025
SINAMICS V20 Inverter
Operating Instructions, 09/2014, A5E34559884

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SINAMICS V20 and is the answer not in the manual?

Questions and answers

Table of Contents