Heal-Tech SpeedoHealer v3.0 User Manual

Electronic speedo and odometer calibrator with top speed memory

Advertisement

Quick Links

- Electronic Speedo and Odometer Calibrator with Top Speed Memory -

1. Foreword

Congratulations on your purchase of a SpeedoHealer calibrator unit.
At Heal-Tech Ltd. we are committed to producing the best calibrator devices available and we would
like to thank you for choosing our product.
The installation kits are packed and sold separately. Please find the latest Application list on our
website (or ask an authorized SH dealer) and purchase the Harness Kit suitable for your bike.
After the installation, it is best to use our
and to generate the step-by-step programming instructions. You can also download the calculator for
off-line use. Reading this Guide is only necessary if you don't have Internet access to our website.

2. Setting and Using your SH

2.1 Assigned functions to SH switches

Switch no. in
ON position
1
2
3
4
5
6
All

2.2 Programming the unit

1. At first, you have to determine the Calibration and Conversion mode values needed for
your application. If you can't access the on-line calculator, refer to chapter 3.
Normally the Conversion mode value is zero, unless you have an import bike/speedo with
different units of measure than in the country you live in.
2. It is recommended to start the programming sequence by a Reset command.
Set all switches to ON position and turn the ignition On. The LED blinks once.
[After a few seconds the product identification code is transmitted via the LED - ignore]
Press the button, the LED lights up. Release the button.
If you wish to set the unit into Transparent mode, then flip all switches down while the
ignition is still on. The LED flashes rapidly for 3 seconds to confirm that all parameters
have been cleared (factory default). Otherwise, continue with the next step.
SH_UsersGuide_en.pdf
http://www.speedohealer.com
SpeedoHealer v3.0
User's Guide
on-line calculator
Selected Function
Test mode on/off
Set the Conversion mode value
Set the Sign of Calibration value
No. of Tens in Calibration value
No. of Ones in Calibration value
No. of Tenths in Calibration value
Reset
to calculate the required calibration value
Possible values set by the button
Change the emitted frequency
(x 2, in 10 steps)
0: no conversion
1: mile → km
2: km → mile
0: Negative
1: Positive
0..9
0..9
0..9
Press to confirm
- 1 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SpeedoHealer v3.0 and is the answer not in the manual?

Questions and answers

Summary of Contents for Heal-Tech SpeedoHealer v3.0

  • Page 1 1. Foreword Congratulations on your purchase of a SpeedoHealer calibrator unit. At Heal-Tech Ltd. we are committed to producing the best calibrator devices available and we would like to thank you for choosing our product. The installation kits are packed and sold separately. Please find the latest Application list on our website (or ask an authorized SH dealer) and purchase the Harness Kit suitable for your bike.
  • Page 2 3. Leave one of the switches between 2 and 6 in ON position (flip down the rest), depending on which parameter you want to program first (refer to table 2.1). After a Reset, all parameters are clear so you have to select and program only those parameters which you want to change.
  • Page 3 3. Calculations (with examples) a) Calculation formulas when measurement data is not available Total Error err_1 err_2 err_3 , where: The 1 error tag comes from the actual wheel size. err_1 = 1.00 1.02 (1.00: new standard tyre; 1.02: bald standard tyre) The 2 error tag comes from the ratio (sprocket) change.
  • Page 4 Let’s suppose you passed 3 kilometer stones in 152 secs with an indicated, steady 80 km/h. Then: Calculated speed km/h 3600 ⎛ ⎞ − → ⎜ ⎟ Calibratio value 11.25 11.3 ⎝ ⎠ c) Using other instrument or vehicle as a speed reference If there is a calibrated instrument on the vehicle (e.g.

Table of Contents