Groen HY-6G Operator's Manual

Groen HY-6G Operator's Manual

Hypersteam atmospheric convection steamer

Advertisement

IMPORTANT INFORMATION
IMPORTANT INFORMATION
IMPORTANT INFORMATION
IMPORTANT INFORMATION
O
P
E
R
A
T
O
R
Part Number 141601
Model: HY-6G
HyPerSteam™
Atmospheric Convection
Steamer
Self-Contained
Gas
Capacity: 6 Steamer Pans
(12" x 20" x 2½")
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND
FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS
INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER. AS
A MINIMUM, TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR
AUTHORIZED SERVICE AGENT. EVACUATE ALL PERSONNEL FROM THE AREA.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING
OR SERVICING THIS EQUIPMENT.
KEEP FOR OPERATOR
KEEP FOR OPERATOR IMPORTANT INFORMATION
KEEP FOR OPERATOR
KEEP FOR OPERATOR
M
A
N
U
A
L
POST IN A PROMINENT LOCATION
IMPORTANT INFORMATION
IMPORTANT INFORMATION
IMPORTANT INFORMATION
WARNING
WARNING
Information contained in this document is
known to be current and accurate at the time
of printing/creation. Unified Brands recom-
mends referencing our product line websites,
unifiedbrands.net, for the most updated
product information and specifications.
O
M
-
H
Y
6 -
G
DOMESTIC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HY-6G and is the answer not in the manual?

Questions and answers

Summary of Contents for Groen HY-6G

  • Page 1 KEEP FOR OPERATOR KEEP FOR OPERATOR IMPORTANT INFORMATION IMPORTANT INFORMATION IMPORTANT INFORMATION IMPORTANT INFORMATION Part Number 141601 DOMESTIC Model: HY-6G HyPerSteam™ Atmospheric Convection Steamer Self-Contained Capacity: 6 Steamer Pans (12" x 20" x 2½”) THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.
  • Page 2: Operator Warnings (Read First)

    Use no de-greaser that contains potassium hydroxide or sodium hydroxide or that is alkaline. WARNING: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT. SERVICE PERFORMED BY...
  • Page 3: Table Of Contents

    Table of Contents OPERATOR WARNINGS (READ FIRST) ........2 EQUIPMENT DESCRIPTION .
  • Page 4: Equipment Description

    WARNING BEFORE REMOVING ANY PARTITION OR PANEL, TURN OFF THE ELECTRICAL POWER AND LET THE FAN STOP ROTATING. The HY-6G has two independent cavities, each with its own base-mounted steam generator. BEFORE WORKING ON ANY ELECTRICAL COMPONENT, DISCONNECT THE POWER SOURCE FROM THE UNIT.
  • Page 5: Water Quality And Treatment

    (TDS) and should have a pH (acidity rating) of 7.0 to 9.0. Please follow these simple precautions: 1. The best way to prevent scale is to use a Groen PureSteem™ Water Treatment System which has been specifically designed for Groen steamers and combination ovens.
  • Page 6: Inspection And Unpacking

    Inspection and Unpacking Your HY-6G HyPerSteam will be delivered Write down the model number, serial number and completely assembled in a heavy shipping carton installation date. Space for these entries is provided and attached to a skid. On receipt, inspect the in the Service Log at the back of this manual.
  • Page 7: Installation And Start-Up Instructions

    A. Installation Maximum load is 2½ AMPs. In Canada, provide electrical service in accordance with the The HY-6G steamer is suitable for installation on or Canadian Electrical Code, CSA C22.1 Part 1 near both combustible and noncombustible surfaces. and/or local codes.
  • Page 8 ANSI Z21.69 — latest edition. Restrain movement of the unit by attaching a After the HY-6G Steamer has been installed, test it cable or chain to the eyelet (provided at the back to ensure that the unit is operating correctly.
  • Page 9 The steam generator will then drain. You may also switch off the pilot switch to conserve energy. 10. If the HY-6G Steamer behaves as described, the unit is functioning correctly and ready for use. Automatic Operation of Pilot Once the pilot burner is lit, it essentially functions as a standing pilot.
  • Page 10: Operating Instructions

    Operation WARNING ALL POTENTIAL USERS OF THE EQUIPMENT SHOULD BE TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES. NO ATTEMPT SHOULD BE MADE TO OPERATE THIS EQUIPMENT DURING A POWER FAILURE. NOTE: Before the steamer can be operated as described in this section, the pilot burner flame must be established.
  • Page 11 5. Open the door. Remove the pans from the WARNING steamer, using hot pads or oven mitts to protect WHEN YOU OPEN THE DOOR, STAY AWAY your hands from the hot pans. FROM THE STEAM COMING OUT OF THE UNIT. THE STEAM CAN CAUSE BURNS.
  • Page 12: Cleaning

    Cleaning To keep your HY-6G Steamer in proper working order, use the following procedure to clean the unit. This regular cleaning will reduce the effort required to clean the steam generators and cavities. A. Suggested Tools WARNING 1. Mild detergent DISCONNECT THE POWER SUPPLY 2.
  • Page 13 RECOMMENDED TOOLS & CLEANERS: door gasket. Close door. - Groen Delimer/Descaler (Part Number 114800). Do NOT use any product containing chlorides or STEP 8- To use steamer, press ON/OFF. When sulfamic acid, including hydrochloric acid .
  • Page 14: Maintenance And Troubleshooting

    Troubleshooting This Groen Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel. If an item on the check list is marked with (<), it means that the work should be done by a factory-authorized service representative.
  • Page 15: Parts Lists

    Parts List External Cabinet and Sheet Metal To order parts, contact your authorized Groen Service Agency. Supply the model designation, part description, part number, quantity, and where applicable, voltage and phase. Description Part # Description Part # Lower Side Panels...
  • Page 16: Parts List

    Parts List Cavity Control Section Description Part # Description Part # Light &Timer PC Board Assy Top Cover Clip 123156 137233 Timer 096826 Cover, Control Panel 143255 Door Switch 096857 Chassis, Trfmr/Capacitor Assy 141472 Ready Thermostat 088865 Steam Port 141366 Steam Hose, Top 145242 Steam Hose, Bottom...
  • Page 17 Parts List Steamer Base Section Description Part # Description Part # Adjustable Table Leg 042505 Igniter Module 085153 Gas Switch 087951 120/24 Volt Transformer 121716 Main Gas Valve, Natural Gas 098443 Main Gas Valve, Propane Gas 098444 Alternate Main Gas Valve 099988 Outer Steam Generator Assy 141618...
  • Page 18 Parts List Steamer Base Section Description Part # Description Part # Inner Gas Manifold 141499 Outer Generator Drain Hose 141466 Outer Gas Manifold 141348 Stm Gen Drain Hose Clamps 095656 Igniter Cable 096728 12 Drain Box 140859 ½” Outer High Heat Tube 141338 13 Upper Cavity Drain Hose 141490...
  • Page 19 Parts List Steamer Motor and Controls 4 4 4 Parts List Steamer Motor and Controls Description Part # Description Part # Fan Motor 096740 Door Switch 096857 Motor Mounting Plate 094134 Steam Port Kit** 141617 Motor Shaft Seal 096868 -Ready Thermostat 088865 Motor Insulator 094135...
  • Page 20 Parts List Steam Generator Individual Parts Description Part # Description Part # Steam Generator Kit (LH) 094127 Bottom Cavity Drain Hose 141456 Steam Generator Kit (RH) 094128 4" Bottom Steam Hose 141455 Right Steam Gen. Insulation* 096896 Sink Drain Hose 099915 Left Steam Gen.
  • Page 21 Parts List Steamer -Individual Parts 2a,2b 2a,2b 10,11 Description Part # Description Part # Main Gas Valve 099988 Control Transformer 094164 Gas Manifold (Left) 141341 Stm. Generator Drain Valve 074594 Gas Manifold (Right) 141341 High Heat Flame Holder 013489 Igniter Module 085153 Pilot Burner - Natural Gas 096705...
  • Page 22: Electrical Schematics

    Electrical Schematic...
  • Page 23: References

    References AMERICAN GAS ASSOCIATION LABORATORIES NATIONAL SANITATION FOUNDATION 8501 East Pleasant Valley Road 3475 Plymouth Road Cleveland, Ohio Ann Arbor, Michigan 48106 AMERICAN NATIONAL STANDARDS INSTITUT1403 NATIONAL FIRE PROTECTION ASSOCIATION Broadway 60 Battery March Park New York, NY 10018 Quincy, Massachusetts 02269 Z21.30 Installation of Gas Appliances &...
  • Page 24: Service Log

    Service Log Purchased From Model No. Location Serial No. Date Installed Date Purchased For Service Call Purchase Order No. Date Maintenance Performed Performed by...
  • Page 25: Warranty Protection

    Groen Foodservice Equipment (“Groen Equipment”) has been skillfully manufactured, carefully inspected, and packaged to meet rigid standards of excellence. Groen warrants its Equipment to be free from defects in material and workmanship for (12) twelve months with the following conditions an subject to the following limitations.
  • Page 26 NOTES...
  • Page 27 1055 Mendell Davis Drive OM-HY-6G (Revised 10/02) Jackson MS 39272 Part Number 141601 Telephone 601 372-3903 FAX 601 373-9587 www.groen.com...

Table of Contents