7.3.2
Scanning motor (and timing belt)
(1)
Remove the top cover.
(2)
Disconnect one connector.
(3)
After removing three screws, you can take out
the whole unit. At this time, the timing belt (2M-
77) is also removed.
Note: 1. When reassembling the parts, make sure
that the timing belt is securely placed on
the pulleys (P66/P18) and the shaft drive
pulley (P22).
2. The scanning motor is screwed on in the
position of the hole A at the time of ship-
ping from the factory.
When the belt tension adjustment is nec-
essary, reinstall the screw at the elongated
hole B (not the hole A).
After having pushed the scanning motor
in the direction of the arrow, install it.
(4)
After taking out the unit, remove two screws
and the motor is removed.
Note: When reassembling the parts, make sure that
the timing belt is securely placed on the pul-
leys (P66/P18) and the shaft drive pulley
(P22).
7.3.3

Mirror motor

(1)
Remove the original glass.
(2)
Remove the optics cover (1 screw).
(3)
After removing two screws, take out the
bracket.
(4)
Remove two screws and disconnect one con-
nector from the bracket and the mirror motor
is removed.