General precautions and safety ............27 Contraindications and warnings ............28-30 Electromagnetic Emissions Information ..........31 uarantee Your Stimplus Pro machine is guaranteed for a period of 2 years against manufacturer’s defects. Please record purchase details in the space provided below for your record purposes.
Page 3
Warning symbols The following symbols appear in these instructions Warning instruction indicating Important safety note Note on important information a risk of injury or damage to indicating possible health damage to the accessories The following symbols are used on the device:- Equipment providing a Denotes a product which must The first number 2:...
Introduction The Body Clock Stimplus Pro is a safe, hi-tech, battery operated electronic substitute for acupuncture, without the use of needles. It can detect acupoints and then indicate them by means of audio and visual signals after which it can treat them with a choice of three pre-set electronic frequencies (or rhythms).
2. To start searching for an acupoint you should hold the Body Clock Stimplus Pro as you would a pen with the web of your hand in contact with the passive contact plate. See diagram on page 5.
Page 6
11. You can use the ear piece to hear the audible signals from the Body Clock Stimplus Pro by yourself, thereby avoiding others having to listen to it if it is not convenient. The ear piece consists of a lead with a jack plug at one end and the...
See diagram on page 9. This means that you will have to replace the batteries as soon as possible. 13. When you have finished using your Body Clock Stimplus Pro do not forget to turn it off. How to achieve best results from your...
Page 8
3. When treating another person the operator or practitioner should position the tip onto the point(s) to be treated and ensure that physical contact is maintained between him/herself and the person being treated in order to complete the circuit. 4. As an alternative to 3 above, you can use the wrist strap to the same effect.
Page 9
6. Good skin care is important in minimizing any potential skin irritation which could occur with active use of the tip. Prepare the skin before using the Body Clock Stimplus Pro by: (a) thoroughly washing the skin sites to be treated with a mild soap and water solution to remove any non-conductive skin oils;...
How it works The Body Clock Stimplus Pro can both SEARCH for acupoints and STIMULATE them. Search Mode: A very low current is utilised to measure the body’s resistance and this information is converted by the device into pitch variations – the lower the resistance, the higher the pitch.
Body Clock Stimplus Pro controls and indicators Acupoint Low Battery 2.5mm Proximity and Indicator Earphone Intensity Jack Indicator ‘Stim’ Indicator ‘Stim’ Switch Intensity Rhythm Power Switch Switch Switch Battery Compartment Tip (gold plate) Passive Contact Time Selector Plate (Passive Switch...
Some important acupuncture charts and conditions The following charts indicate acupuncture points with red stars and blue dots. The red stars indicate primary points and blue dots indicate secondary and supporting points. Area of pain Page no. A. Pain in the arms or elbows B.
3. The Body Clock Stimplus Pro is not user repairable and must be returned to the manufacturer if it requires repair. 4. Do not place the Body Clock Stimplus Pro close to any source of excessive heat and do not use it in the presence...
6. Do not use this unit without first reading the instructions. 7. Do not immerse the Body Clock Stimplus Pro in water or any liquid, nor allow any liquids to get into the device.
Page 31
• Do not use on the sides of the neck or internally. • Do not use the Body Clock Stimplus Pro to treat undiagnosed pain since it could require urgent treatment.
Page 32
2. Do not stimulate any area of skin which is sore or inflamed or does not have normal sensation. 3. The Body Clock Stimplus Pro must be used in accordance with the EMC information posted in this manual. 4. Portable and mobile RF communications equipment can affect the Body Clock Stimplus Pro.
Recommended separation distances between portable and mobile RF communications equipment and the Body Clock Stimplus Pro The Body Clock Stimplus Pro is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The user of the equipment or system can help prevent...
Page 34
RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Body Clock Stimplus Pro is used exceeds the applicable RF compliance level above, the Body Clock Stimplus Pro should be observed to verify normal operation.
Page 35
Guidance and manufacturer’s declaration - electromagnetic immunity The Body Clock Stimplus Pro is intended for use in the electromagnetic environment specified below. The user of the equipment or system should ensure that it is used in such an environment Immunity test...
Page 36
Body Clock Health Care Ltd 108 George Lane, South Woodford, London E18 1AD United Kingdom Tel (+44) (0)20 8532 9595 Fax (+44) (0)20 8532 9551 www.bodyclock.net e-mail customercare@bodyclock.net 0120 July 2016 (2) This manual is recyclable...