Electrical and Fuel Inlet Locations

The 3/4 inch N.P.T. fuel inlet connector
B
location
is shown below.
A ½ inch knock-out is provided for the electrical inlet. This
inlet may be enlarged or supplemented to accommodate
a maximum conduit size of 1 ½ inches. Ensure that the
installed conduit(s) enter the unit in the zone shown in the
drawing such that they properly enter the electrical box and
do not interfere with the fully opened roof.
B
A
A
and electrical inlet
The home generator is supplied with a base that, unless
mandated by local code, does not require a concrete slab.
17