Advertisement

Quick Links

elero GmbH
Antriebstechnik
Linsenhofer Str. 59–63
D-72660 Beuren
info@elero.de
www.elero.com
309022 00
AstroTec
Bedienungsanleitung
DE
Bitte bewahren Sie die Bedienungsanleitung auf !
Uhr ist voreingestellt

Operating instructions

GB
Please keep these instructions in a safe place!
Timer is preprogrammed
Instructions d'utilisation
FR
Veuillez conserver les présentes instructions d'utilisation !
L'heure est preréglée
Nr. 18 100.3201/0604
elero

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AstroTec and is the answer not in the manual?

Questions and answers

Summary of Contents for elero AstroTec

  • Page 1: Operating Instructions

    AstroTec Bedienungsanleitung Bitte bewahren Sie die Bedienungsanleitung auf ! Uhr ist voreingestellt Operating instructions Please keep these instructions in a safe place! Timer is preprogrammed Instructions d’utilisation elero GmbH Antriebstechnik Veuillez conserver les présentes instructions d’utilisation ! Linsenhofer Str. 59–63 L’heure est preréglée...
  • Page 2: Table Of Contents

    Contents Contents Safety instructions ........GB- 3 Programming menu Explanation of displays and buttons .
  • Page 3: Safety Instructions

    VDE 100 must be observed for system installation. • For use in dry rooms only. Buttons under the cover Reset button • Use unmodified elero original parts only. • Keep persons away from the systems guide track. MENU button Reset MENU –...
  • Page 4: Designated Use

    Designated use • The switched current of the device must be observed at all times!. The AstroTec may only be used to control roller shutter and venetian blind systems. 1. Remove the protective caps. 2. Connect.
  • Page 5: Connection As A Group Controller

    Connection as a group controller Initial operation For details on suitable control systems, please refer to the control To activate the AstroTec timer, touch any button on the device. To product catalogue. select the language required use the +/- buttons and confirm your selection with the OK button.
  • Page 6: Light Sensors

    Light sensors +/- buttons The following operations are possible using the + and - buttons: Note: If you wish to connect a light sensor to the AstroTec, the instructions provided with the light sensor must be followed. • Menu W change value •...
  • Page 7: Programme

    Explanation of functions Explanation of functions Programme ASTRO The AstroTec automatically controls your roller shutters or PROGRAMME blinds at the pre-set sunrise and sunset times. These times are The PROGRAMME menu allows you to set various switching times: used as guidelines.
  • Page 8 Explanation of functions Explanation of functions WEEK SWITCHING TIME Using the WEEK menu, you can set the same switching times from Automatic switching times for roller shutters and blinds to be rai- Monday – Sunday (1-7). sed and lowered. BLOCK OFFSET Using the BLOCK menu, you can set two blocks.
  • Page 9: Intermediate Position, Ventilation/Reverse

    Explanation of functions Explanation of functions SETTING INTERMEDIATE POSITION The intermediate position is a position of the roller shutter/blind The SETTING menu gives you the following options: between the upper and lower limits that can be freely selected. • HOLIDAY This position can also be reached from the upper position after •...
  • Page 10: Drive Controller/Group Controller

    SUMMER/WINTER describes the automatic clock adjustment for SWITCH switched off in manual mode. daylight saving changes. If the default setting is ON, the AstroTec timer adjusts itself automatically. EXPERT MODE If selecting the city (EXPERT MODE OFF) is not precise enough, you can make a fine adjustment by setting the degrees of longitude and latitude (EXPERT MODE ON).
  • Page 11 Programming Programming Main menu (Overview of the menu) PROGRAMME PROG 1/ASTRO WEEK (Astro function for week + idle period v b) Operating mode PROG 1/ASTRO BLOCK (Astro function for block1/2 + idle period v b) MENU PROG 1/ASTRO INDIVIDUAL (Astro function for individual + idle period v b) +/–...
  • Page 12 Programming Programming WEEK 4. Confirm by pressing OK. ASTRO EVENING appears. Press +/- for the WEEK menu level (1-7). All further entries now refer 5. Confirm by pressing OK. to every day of the week. 6. Now select the PROG1 ASTRO function you require using +/- : Confirm by pressing OK.
  • Page 13 Programming Programming PROGRAMME INDIVIDUAL Press +/- for the INDIVIDUAL menu level (1,2,3,4,5,6,7). PROG 1/INDIVIDUELL WEEK (Individual switching time vb for week) All further entries now refer to every individual day of the week. PROG 1/INDIVIDUELL BLOCK (Individual switching time vb for block1/2) Confirm by pressing OK.
  • Page 14: Ventilation Position

    Programming Programming 7. Now select the PROG2 INDIVIDUAL function you require using PROGRAMME the +/- buttons: PROG 2/OFFSET (e.g. shutters are lowered to ventilation position in BLOCK the evening) Press +/- for the BLOCK menu level (BLOCK 1 (1-5), PROGRAMME BLOCK 2 (6,7)).
  • Page 15 Programming Programming SETTING SETTING HOLIDAY, LIGHT SENSOR (Holiday OFF/ON, sun/twilight setting) INTERMEDIATE POSITION, VENTILATION/REVERSE, PROG 1 END LIMIT (Time/ position programming) LIGHT SENSOR SETTING HOLIDAY OFF VENTILATION PROG1 CONNECTED ? INTERMEDIATE next page previous page (REVERSE) END LIMIT next page POSITITION +/–...
  • Page 16 Programming Programming SETTING SETTING PROG 2 END LIMIT (Time/position programming) ENGLISH GB/ASTRO SHIFT v b (Language, astro shift) PROG2 previous page END LIMIT next page ASTRO TEST MODE previous page ENGLISH GB ON/OFF SHIFT v +/– +/– +/– +/– PROG2 INTERMEDIATE POSITION ASTRO...
  • Page 17 Programming Programming 7. You can set the required astro shift b (max. +/- 120 mins.) using Note: These dialog windows (LONGITUDE, LATITUDE, TIME ZONE) the +/- button. are only displayed when the EXPERT MODE in the function menu is ON. 8.
  • Page 18 Programming Programming FUNCTION (only when the operating device is disconnected, only for FUNCTION (only when the operating device is disconnected, only for qualified electricians) qualified electricians) ROLLER SHUTTER/BLIND, DRIVE CONTROLLER/GROUP CONTROLLER, EXTERNAL ON/OFF/SWITCH, ALARM SIGNAL ON/OFF RUNNING TIME (Processing external signals, processing alarm signals) (Selection of shutter/blind, selection of the drive controller/ group controller, running time of the roller shutter/blind) Drive controller ?
  • Page 19: Technical Data

    Programming Technical data/Battery replacement/Cleaning FUNCTION (only when the operating device is disconnected, only for Technical data qualified electricians) Nominal voltage 230-240 V AC / 50-60 Hz INITIAL OPERATION, RELAY, TOTAL RUNNING TIME Switched current 5 A /250 V AC for cos j =1 (Date of initial operation, relay switching rate, total running time) Battery type CR 2032...
  • Page 20: Troubleshooting

    Troubleshooting General declaration of conformity Troubleshooting The company elero GmbH hereby declares that the AstroTec is in conformity with the basic requirements and other relevant provi- Problem Cause Remedy sions of the Directive 1999/5/EC. Drive is not Faulty connection. Check the connection.