Nice HOPP HO7124 Instructions For Installation And Use Manual

Swing gate opener
Hide thumbs Also See for HOPP HO7124:

Advertisement

HOPP
HO7124
HO7224
Swing gate opener
EN -
Instructions and warnings for installation and use
IT -
Istruzioni ed avvertenze per l'installazione e l'uso
FR -
Instructions et avertissements pour l'installation et l'utilisation
ES -
Instrucciones y advertencias para la instalación y el uso
DE -
Installierungs-und Gebrauchsanleitungen und Hinweise
PL -
Instrukcje i ostrzeżenia do instalacji i użytkowania
NL -
Aanwijzingen en aanbevelingen voor installatie en gebruik

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HOPP HO7124 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nice HOPP HO7124

  • Page 1 HOPP HO7124 HO7224 Swing gate opener EN - Instructions and warnings for installation and use IT - Istruzioni ed avvertenze per l’installazione e l’uso FR - Instructions et avertissements pour l’installation et l’utilisation ES - Instrucciones y advertencias para la instalación y el uso DE - Installierungs-und Gebrauchsanleitungen und Hinweise PL -...
  • Page 3: Table Of Contents

    Incorrect installation may cause serious injury. Before commencing work, all sections of the manual must be read carefully. If in any doubt, suspend installation and call the Nice Support Service for clarifi- cation. • IMPORTANT! – This manual contains important instructions. Keep it for future maintenance work and disposal of the product.
  • Page 4: Installation

    3.3 - Preliminary installation set-up work Fig. 3 provides an example of an automation system, produced using Nice com- INSTALLATION ponents (some components may not be present in the kit): a - Gearmotor with control unit model HO7124 b - Gearmotor without control unit model HO7224 3.1 - Pre-installation checks...
  • Page 5: Mechanical Limit Switch Adjustment

    HO7224 Overlapping leaf HO7124 must be made by means of the Nice “Bluebus” system. Description of electrical connections (fig. 11) AERIAL input for the radio receiver aerial Overlapping leaf...
  • Page 6: Initial Start-Up And Connection Check

    the electric jumper correctly on each device; see the relative instruction manual ing). There are three ways to perform this procedure: automatic, manual or of individual devices: see fig. A and Table 3. combined. To route other devices, consult the relative instruction manuals. At the end of In automatic mode, the control unit learns the positions of the mechanical the installation procedure, or after removing photocells or other devices, the stops and calculates the most suitable offset value for the leafs (SA and SC,...
  • Page 7: Gate Leaf Movement Check

    For all the documentation mentioned, the Nice technical support service pro- Check correct offset of the leafs on opening. At the end of the manoeuvre, vides the following: instruction manuals, guides and precompiled forms.
  • Page 8: Control Panel Programming

    STOP/SET: key for stopping a manoeuvre; if pressed for more than 5 seconds, PROGRAMMING THE CONTROL UNIT it enables entry to programming mode. CLOSE (u): – key for controlling gate closure; – selection key during programming. 6.1 - Level one programming (ON-OFF functions The control unit has 3 keys OPEN (), STOP (SET), CLOSE (u) that can be All level 1 functions are set by default to “OFF”...
  • Page 9 TABLE 7 - Second level functions Input LED Parameter Value Description (level) Pause time 5 seconds Sets the pause time, namely the time which lapses before automatic clo- 15 seconds sure. This will only take effect if closing 30 seconds is active.
  • Page 10: Special Functions

    List of Manoeuvre 1 result (most recent) The type of fault that has occurred in faults the last 8 manoeuvres can be establi- Manoeuvre 2 result shed Manoeuvre 3 result See TABLE 12 – Fault log. Manoeuvre 4 result Manoeuvre 5 result Manoeuvre 6 result Manoeuvre 7 result Manoeuvre 8 result...
  • Page 11: Troubleshooting

    se. Table 10 shows the cause and solution for each type of signal. WHAT TO DO IF… The LEDs on the control unit also emit signals. Table 11 shows the cause and (troubleshooting guide) solution for each type of signal. It is possible to verify faults that have occurred during the last 8 manoeuvres.
  • Page 12: Further Information

    TABLE 12 - Fault log 01. Press and hold down the “Set” key for approx. 3 seconds; 02. Release the key when LED “L1” starts flashing; 03. Press keys “” or “u” to move from the flashing LED to L8 LED (“input LED”) for the “Fault log” parameter; 04.
  • Page 13: Connecting The Oview Programmer

    8.3 - Connection of the Oview programmer For more information on the Solemyo system, refer to the relative instruction manual. The control unit has a BusT4 connector to which the Oview programming unit To connect the Solemyo system, proceed as shown in fig. 19. can be connect, and which allows the complete rapid management of the instal- lation and maintenance phase as well as the diagnosis of the entire automation 8.5 - Connecting the external release system Kio...
  • Page 14: Technical Specifications Of Product

    TECHNICAL SPECIFICATIONS OF PRODUCT WARNINGS: • All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right to apply modifi- cations to products at any time when deemed necessary, maintaining the same intended use and functionality.
  • Page 15: Product Lifetime

    GRAPH 3 PRODUCT LIFETIME 250000 The lifetime is the average economic duration of the product. The value of lifeti- me is strongly influenced by the intensity of the manoeuvres performed by the automation. i.e. the sum of all factors that contribute to product wear (see Table 200000 15).
  • Page 16: Ce Declaration Of Conformity

    Declaration in accordance with the Directives: 2004/108/EC (EMC); 2006/42/EC (MD) appendix II, part B Note - The contents of this declaration correspond to declarations in the official document deposited at the registered offices of Nice S.p.a. and in partic- ular to the last revision available before printing this manual. The text herein has been re-edited for editorial purposes.
  • Page 17 Technical documentation Images Documentazione Tecnica Immagini Documentation Technique Images Documentación Técnica Imágenes Technische Dokumentation Bilder Dokumentacja Techniczna Zdjęcia Technische documentatie Afbeeldingen...
  • Page 18: Instructions And Warnings For The User

    Instructions and warnings for the user Before using the automation system for the first time, allow the installer to • If the automation system was secured with the command "Secure explain the origin of the residual risks and take a few minutes to read this automation system”: after a command is sent, the gate does not move and instruction manual and the warnings for the user which the installer has handed the flashing light emits 9 brief flashes.
  • Page 19 MIN 400 mm 180 mm 252 mm IX IX...
  • Page 20 180°...
  • Page 21 180° 180°...
  • Page 22 24V 4W NC NO NO NC P.P. STOP – 24 Vcc FLASH S.C.A. BLUEBUS P.P. STOP OPEN...
  • Page 26 Nice SpA Oderzo TV Italia www.niceforyou.com info@niceforyou.com...

This manual is also suitable for:

Hopp ho7224