3104A076 Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. If you purchase the products from the sales agent of Huawei Technologies Co., Ltd., please contact our sales agent. If you purchase the products from Huawei Technologies Co., Ltd. directly, Please feel free to contact our local office, customer care center or company headquarters.
Chapter 1 Product Overview The chapter introduces the characteristics of S6502 Ethernet Switch according to the forwarding engines. Chapter 2 Line Processing Unit The chapter introduces LPUs of S6502 Ethernet Switch. Chapter 3 Installation Preparation The chapter introduces the installation preparation and precaution of S6502 Ethernet Switch.
Page 5
Chapter 5 System Debugging The chapter introduces the system debugging. Chapter 6 Switch Monitoring and Maintenance The chapter introduces the monitoring and maintenance of S6502 Ethernet Switch. Appendix A Lightning Protection of the Switch The appendix introduces lightning protection of S6502 Ethernet Switch.
Page 6
Note, Comment, Tip, Knowhow, Thought: Means a complementary description. Environmental Protection This product has been designed to comply with the requirements on environmental protection. For the proper storage, use and disposal of this product, national laws and regulations must be observed. Huawei Technologies Proprietary...
Page 9
Installation Manual Quidway S6502 Ethernet Switch Table of Contents 2.16 LS81GP8UB-8-port 1000Base-X (SFP) Ethernet Card..........2-29 2.16.1 Introduction to Card..................... 2-29 2.16.2 Panel and LEDs ....................2-30 2.16.3 Matching Cable ....................2-31 2.17 LS82GP20-20-port 1000Base-X (SFP) Ethernet Card..........2-31 2.17.1 Introduction to Card..................... 2-31 2.17.2 Panel and LEDs ....................
Page 10
Installation Manual Quidway S6502 Ethernet Switch Table of Contents 4.5 Connect Ground Wire and Power Cord................4-2 4.5.1 Connect Ground Wire ..................... 4-2 4.5.2 Connect AC Power Cord..................4-5 4.6 Install Cabling Rack ......................4-6 4.7 Install Switch Boards ......................4-6 4.8 Connect Port Cables......................
Page 11
Installation Manual Quidway S6502 Ethernet Switch Table of Contents 6.3.6 Dealing with Failed Loading .................. 6-25 6.3.7 Dealing with Lost Password .................. 6-26 Appendix A Lightning Protection of the Switch.................A-1 A.1 Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection)..A-1 A.2 Installation of Lightning Arrester for Network Port.............A-2...
络 络 Figure 1-1 S6502 in a MAN S6502 supports 1+1 redundant AC and DC power supplies. One of its slots is designed for switching engine and the other for the LPU. Both of them can provide high-density service ports.
LPU software. Processing monitoring signals on the power system and fans, which are transferred through the backplane. In addition to these functions, the SRPU of S6502 also can provide high-density service ports: LS81P12TE: provides four 10/100/1000BASE-T ports and 12 × 1000BASE-X (SFP) ports.
LS81TGX1B √ √ LS81TGX1C √ √ LS81T12PE √ √ LS81P12TE √ √ 1.6 Overall Hardware Layout of S6502 1.6.1 Chassis I. Front view S6502 uses the XG high-speed bus, whose chassis is labelled with silk-printed characters: XGbus. Huawei Technologies Proprietary...
Page 20
(for PoE management), console port, 10Base-T/100Base-TX management port and its status LED, fan LED, card status LED. S6502 provides two horizontal slots, with the upper for SRPU and the lower for LPU. The SRPU is mandatory, and the lower slot can hold many types of LPU cards.
Page 21
Quidway S6502 Ethernet Switch Chapter 1 Product Overview Note: S6502 switch can provide power to the powered devices (PDs) connected, such as IP phone sets, WLAN access point (AP), through the external PoE power distribution unit and its card supporting PoE function.
Page 22
Installation Manual Quidway S6502 Ethernet Switch Chapter 1 Product Overview Item Description Function For system software upgrade and network management The corresponding LEDs are described in the following table. Table 1-11 Management port status LEDs Status No link is presented.
(1) PoE power input (2) Grounding screw Figure 1-7 Rear view of an S6502 chassis An S6502 chassis provides -48V DC input for connection with external PoE power distribution unit. Note: The backplane, SRPU, power module and fan tray all are required components in S6502.
Page 24
Quidway S6502 Ethernet Switch Chapter 1 Product Overview Note: The S6502 supports either AC or DC input, but they cannot run concurrently. You can choose the specific type as needed. Although the system can operate normally when one power module is working, the S6502 still provides two slots for power modules, in attempt to support 1+1 redundancy.
1.6.5 Fan Tray The fan tray is at the right side of an S6502 chassis, and directly connected to the backplane through a connector. The fan fault signals are summarized and transmitted from the backplane to the SRPU for further processing.
Installation Manual Quidway S6502 Ethernet Switch Chapter 1 Product Overview Figure 1-9 Fan tray on an S6502 1.7 Technical Specifications Table 1-16 System specifications Item S6502 Physical dimensions (H × W × 130.5 x 436 x 400 mm (5.12 x 17.2 x 15.8 in.) Weight (fully configured) ≤44 lb (20 kg )
Chapter 2 Line Processing Unit 2.1 Brief Introduction to LPU Based on industry standard and complying with modular designing idea, S6502 combines advantages of the mainstream products in the field. The reasonable division of the system module ports makes it has a sound system structure and standardized and independent functional modules.
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Attribute LS81FT48E IEEE802.3 IEEE 802.3ad IEEE802.3x IEEE802.1p Conformed standard IEEE802.1D IEEE802.1Q IEEE802.1X IEEE802.1s IEEE802.1w 2.3.2 Panel and LEDs Figure 2-4 LS81FT48E panel Every port has a green LED. The following table describes the LED state.
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit 2.4 LS81FT48F-PoE-Supported 48-port 10/100Base-T Fast Ethernet Card Figure 2-5 LS81FT48F appearance 2.4.1 Introduction to Card This LPU provides 48 × 10/100 Mbps auto-sensing Ethernet electrical interface service channels. And all the interfaces support PoE, that is, to implement remote power supply to PDs through Ethernet twisted pair cables.
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Attribute LS81FT48F Maximum power Each port provides a maximum power of 15.4 W for the each port connected device. provide IEEE802.3 IEEE802.3x IEEE 802.3ad IEEE802.1p IEEE802.1D Conformed standard IEEE802.1Q IEEE802.1X...
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Description Attribute LS81FM24A LS81FS24A Optical fiber 62.5/125 µm multimode 9/125 µm single mode optical maximum optical fiber cable with the fiber cable with the maximum transmission maximum transmission transmission distance of 15 km distance distance of 2 km (1.2 mi)
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Attribute LS81FP48 IEEE802.3 IEEE802.3u IEEE802.3x IEEE802.3ad IEEE802.1p Conformed standard IEEE802.1D IEEE802.1Q IEEE802. 1X IEEE802.1s IEEE802.1w 2.6.2 Panel and LEDs Figure 2-10 LS81FP48 panel Each 100 Mbps electrical port has a green LED with it, which is described in the following table.
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Attribute LS81GT8UA IEEE 802.3ab IEEE802.3 IEEE802.3x IEEE802.3ad IEEE802.1p Conformed standard IEEE802.1D IEEE802.1Q IEEE802.1X IEEE802.1s IEEE802.1w 2.7.2 Panel and LEDs Figure 2-12 LS81GT8UA panel Every port has two LEDs. The following table describes the LED state.
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Attribute LS81GT8UE IEEE 802.3ab IEEE802.3 IEEE802.3x IEEE802.1D Conformed standard IEEE802.1Q IEEE802.1X IEEE802.1s IEEE802.1w 2.8.2 Panel and LEDs Figure 2-14 LS81GT8UE panel Every port has two LEDs. The following table describes the LED state.
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit 2.9.2 Panel and LEDs Figure 2-16 LS82GT20 panel Every port has one LED. The following table describes the LED state. Table 2-18 LED state description of LS82GT20 State Description No link is present.
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Table 2-20 LED state description of LS82GT20A State Description No link is present. LINK/ACT A link is present Blinking Packets are being transmitted/received on the port. 2.10.3 Matching Cable The matching cable to the interface is category-5 twisted pair with a maximum transmission distance of 100 m (328 ft).
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Attribute LS81GT48 IEEE 802.3ab IEEE802.3 IEEE802.3x IEEE802.1p Conformed standard IEEE802.1D IEEE802.1Q IEEE802.1X IEEE802.1s IEEE802.1w 2.11.2 Panel and LEDs Figure 2-20 LS81GT48 panel Every port has a LED. The following table describes the LED state.
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit 2.12 LS81GT48A-PoE-Supported 48-port 10/100/1000Base-T Ethernet Card Figure 2-21 LS81GT48A appearance 2.12.1 Introduction to Card This LPU provides 48 x 10/100/1000 Mbps auto-sensing Ethernet electrical interface service channels. And all the interfaces support PoE, that is, to implement remote power supply to PDs through Ethernet twisted pair cables.
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Attribute LS81GT48A IEEE 802.3ab IEEE802.3 IEEE802.3x IEEE802.1p IEEE802.1D Conformed standard IEEE802.1Q IEEE802.1X IEEE802.1s IEEE802.1w IEEE802.3af 2.12.2 Panel and LEDs Figure 2-22 LS81GT48A panel Every port has a LED. The following table describes the LED state.
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Attribute LS81P12T Dimensions (L × W) 366.7 × 340 mm (14.4 × 13.4 in.) Maximum power consumption 35 W Connector RJ-45, LC Number of interfaces 1000 Mbps full-duplex (optical/electrical)
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Table 2-34 LED state description of LS81GP8UB State Description No link is present. LINK/ACT A link is present Blinking Packets are being transmitted/received on the port. 2.16.3 Matching Cable Refer to Table 2-27.
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit 2.18.2 Panel and LEDs Figure 2-34 LS82GP20A panel The following table describes the LED state. Table 2-38 LED state description of LS82GP20A State Description No link is present. LINK/ACT...
Installation Manual Quidway S6502 Ethernet Switch Chapter 2 Line Processing Unit Attribute LS81TGX1B Maximum power consumption 35 W Connector Number of interfaces 10 GE Interface transmission speed Full-duplex 10GBASE-SR-XENPAK (multimode optical fiber, 850 nm, 300 m) 10GBASE-LR-XENPAK (single mode optical fiber,...
Do not place the switch on a moist area and avoid liquid flowing into the switch. 3.1.3 Moving The S6502 is rather big and heavy, so follow the recommendations below when moving them. Turn off all powers and remove all the power cords before moving the chassis.
Note: The ESD wrist strap is shipped with the S6502. There is an ESD wrist strap hole on the left side of the S6502 power module. The grounding screw is located on the bottom right corner of the chassis rear.
Chapter 3 Installation Preparations 3.1.5 Laser Some LPUs of S6502 have optical ports. In operating status, it is prohibited to stare into the open optical port because the laser emitted from it has very high power density and is harmful to your retina.
Installation Manual Quidway S6502 Ethernet Switch Chapter 3 Installation Preparations Table 3-1 Required specifications on dust density in an equipment room Mechanical active Unit Content material ≤3 x 10 Dust particle particles/m³ (No visible dust on desk in three days) Note: Dust particle diameter ≥...
AC input voltage: 100 VAC to 240VAC, 47 Hz to 63 Hz Power output: 300W 3.3 Installation Planning Since the S6502 is a kind of complex equipment, it is necessary to make a good plan and arrangement concerning installation position, networking measure, power supply and cabling before installing it.
Multimeter, 500V Meg-ohmmeter (used to measure the insulation resistance), error detector, optical Instruments power meter and earth resistance tester Note: The instruments and tools are not shipped with the S6502, so you need to make them available by yourself. Huawei Technologies Proprietary...
Quidway S6502 Ethernet Switch Chapter 4 Hardware Installation Chapter 4 Hardware Installation S6502 shall work in a fixed place indoors. 4.1 Confirm the Installation Preparation Make sure that you have read Chapter 3 carefully. All requirements introduced in Chapter 3 have been met.
Quidway S6502 Ethernet Switch Chapter 4 Hardware Installation 4.3 Mount the Switch in 19-Inch Standard Rack S6502 has an integrated chassis and should operate indoors. Take the following installation steps. Step 1: Confirm the following before installation: The rack has been well fixed. The installation position for the switch has been well arranged and there is no obstacle around.
Page 72
Installation Manual Quidway S6502 Ethernet Switch Chapter 4 Hardware Installation Note: The grounding screw is located on the bottom right corner of the chassis. I. Common grounding environment Step 1: Remove the screw from the grounding hole in the switch chassis.
(2) Bail latch (3) Handle of power module (4) Power LED Figure 4-5 S6502 power module The power module has AC input socket with bail latch and a power LED on its front panel (The LED is described in 6.1.2).
Quidway S6502 Ethernet Switch Chapter 4 Hardware Installation 4.6 Install Cabling Rack For your convenience, cabling racks are shipped together with an S6502. Take the following steps to install the rack. Step 1: Face the I/O card slot of the switch;...
Installation Manual Quidway S6502 Ethernet Switch Chapter 4 Hardware Installation Note: Save the removed blank panel for future use. 4.8 Connect Port Cables 4.8.1 Connect Console Cable I. Introduction Console cable is an 8-core shielded cable. One end of the cable is a crimped RJ-45 connector, which is to be plugged into the console port of the switch.
4.8.2 Connect Category-5 Cables I. Introduction The 10Base-T/100Base-TX and 1000Base-T ports of an S6502 match RJ-45 connectors, and are MDI/MDIX autosensing. You can use category-5 cables to connect it. The following figure illustrates the appearance and pinouts of an RJ-45 connector.
Installation Manual Quidway S6502 Ethernet Switch Chapter 4 Hardware Installation Note: Tx refers to Outbound Rx refers to Inbound BI refers to Bi-directional Table 4-3 RJ-45 MDI-X port pinout assignment 10Base-T/100Base-TX 1000Base-T Pinout Signal Function Signal Function Bi-directional data cable...
Page 79
Installation Manual Quidway S6502 Ethernet Switch Chapter 4 Hardware Installation which makes optical system debugging and maintenance more convenient and transit dispatching more flexible. Among multiple fiber connectors, only SC, LC, and MT-RJ will be introduced here. MT-RJ fiber connector: It integrates two channels of light sources into a single fiber, which reduces the actual ports that are in use of a connector.
Installation Manual Quidway S6502 Ethernet Switch Chapter 4 Hardware Installation Caution: When the optical port has not been connected with a fiber connector or its dustproof cover is open, there might be some invisible radiation emitted from the optical port. So do not stare into the optical port directly.
Page 81
Use the right type of ties to bind the cables. Do not bind any cables with tied ties. Huawei technologies provides the following types of ties: 100*2.5mm, 150*3.6mm, 300*3.6mm, 530*9mm, and 580*13mm; Bind the cables with ties and cut the extra parts. Trim the cut and leave no sharp points.
Page 82
Installation Manual Quidway S6502 Ethernet Switch Chapter 4 Hardware Installation Figure 4-13 Cable binding example II Before bending the cables, bind them first. Mind that no tie binds the bended part of any cables, for fear of cable core breaking due to excessive stress. See the following figure.
Installation Manual Quidway S6502 Ethernet Switch Chapter 4 Hardware Installation For the cable terminals fixed with screw thread, the screws or nuts should be fastened and prevented from loosing. See the following figure; Flat Flat Flat Flat Spring Spring washer...
Page 84
Installation Manual Quidway S6502 Ethernet Switch Chapter 4 Hardware Installation Caution: Confirm that you have turned off the power before checking, otherwise, improper connection will hurt people or the component of the switch. After installing the switch, please check if the items listed in the following table are normal.
Installation Manual Quidway S6502 Ethernet Switch Chapter 5 System Debugging Chapter 5 System Debugging 5.1 Setting up Configuration Environment 5.1.1 Setting up Configuration Environment A terminal (a PC in this example) is connected to the switch console port through a console cable.
Page 86
Installation Manual Quidway S6502 Ethernet Switch Chapter 5 System Debugging Step 1: Start the PC and run the terminal emulator (such as Terminal on Windows3.1 HyperTerminal Windows95/Windows98/Windows 2000/Windows NT/Windows XP/Windows ME). Step 2: Set the parameters for Windows98 HyperTerminal as follows: Click Start >...
Page 87
Installation Manual Quidway S6502 Ethernet Switch Chapter 5 System Debugging Figure 5-3 Setting serial port for HyperTerminal connection After selecting serial ports, click <OK>. The following interface will pop up for setting serial port parameters. Set the baud rate to 9600, data bits to 8, parity check to none, stop bits to 1 and flow control to none.
Page 88
Installation Manual Quidway S6502 Ethernet Switch Chapter 5 System Debugging After setting serial port parameters, click <OK>. Then the system will enter the HyperTerminal dialogue box as shown in the following figure. Figure 5-5 HyperTerminal interface In the above dialogue box, select the Properties icon to enter the properties window.
Check if any system indicator on the SRPU indicates abnormal condition. 5.2.4 Booting Interface As the switch is started, the configuration terminal will yield the following output: Starting..RAM Line..OK System is booting....****************************************** Quidway S6502 BOOTROM, Version 500 Huawei Technologies Proprietary...
Page 90
<Quidway> Note: The S6502 provides a variety of command views. For the specific descriptions on the configuration commands and command line interfaces, refer to Quidway S6500 Series Ethernet Switches Operation Manual and Quidway S6500 Series Ethernet Switches Command Manual.
This chapter describes how to troubleshoot. On the SRPU of the S6502, you can find the state LEDs of LPU, power supply, and fan and locate the faults accordingly. 6.1.1 Configuration System Troubleshooting After the switch is powered on and the system is normal, the booting information will be displayed on the configuration terminal.
The blank filler plates are furnished on the chassis where there is no card inserted. 6.1.4 Cards Troubleshooting The LEDs of LPUX (X ranges from 1 to 2 in the S6502) show the state of these cards respectively. Huawei Technologies Proprietary...
Step 2: Pull the module to be replaced until it slides out of the slot. Caution: Because the S6502 power module is heavy, use both hands to pull it out. Hold the module in one palm and gently pull the handle with the other hand. Install a blank filler panel on the chassis for dust-proof and heat dissipation if you will not install another module in this position.
Check it carefully. 6.2.2 Service Card Replacement SRPU and LPUs of the S6502 can be installed and removed basically in the same way. This section describes the general measures of installing and removing these cards. Cards of the S6502 are hot-swappable.
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance Step 2: Hold the ejector levers on the card with both hands and press them toward both sides of you to separate the connectors of the card from the motherboard.
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance II. Replacing fan frame Step 1: Wear the ESD wrist strap. Loosen the captive installation screws in the fan frame. Hold the fan frame with one hand, and pull the handle of the frame outward with the other, making the fan frame pin disconnected from the backplane.
I. Boot Menu After power on, the switch will run BOOTROM program first and the terminal will display the following information: ****************************************** Quidway S6502 BOOTROM, Version 500 ****************************************** Copyright(C) 2001-2008 by HUAWEI-3COM TECHNOLOGIES CO.,LTD. Creation date: Feb 23 2005, 09:36:37...
Page 98
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance Memory Size : 256MB S6502 main board self testing........ SDRAM Data lines Selftest.........OK! SDRAM Address lines Selftest......OK! SDRAM fast selftest........OK! Please check LEDs.....LEDs selftest finished! CPLD selftest..........OK! The switch Mac address is .....0000.0309.0004 Press Ctrl+B to enter Boot Menu...
Page 99
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance Reboot Enter your choice(0-5): II. Loading software from console port using XModem Introduction to XModem XModem is a file transfer protocol widely used due to its simplicity and good functions.
Page 100
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance Step 3: Choose an appropriate download baud rate. Type <5> as shown in the above example to choose the baud rate of 115200 bps. Press <Enter>. The system displays...
Page 102
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance Step 6: Click the Disconnect icon to disconnect HyperTerminal from the switch and then click the Connect icon to re-establish the connection using the new baud rate setting.
Page 103
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance Figure 6-7 Sending file interface After completing the downloading, the system displays the following information: Downloading ...CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCdone! Are you sure to update SRPU bootrom? Yes or No(Y/N)y Step 10: Enter <Y> to start file downloading and <N> to return to the program downloading menu.
Page 104
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance Step 12: Reset HyperTerminal’s baud rate to 9600 bps with reference to Steps 5 and 6 described above. Note: You do not need to reset the HyperTerminal’s baud rate and can skip the last step if you have chosen 9600 bps.
Page 105
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance Step 3: Run terminal emulation program on the PC that is connected to the console port. Start the switch, access Boot Menu, and then enter download protocol menu.
Page 106
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance Select <1>. The subsequent steps are the same as those for loading BOOTROM, except for the displayed prompt messages. IV. Loading Software from Ethernet Port Using FTP Introduction to FTP A switch can be used via Ethernet port as an FTP server or a client to provide another approach for software loading and file configuration.
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance Step 4: In the download protocol menu, type <2> to select FTP protocol to download BOOTROM and host software. Press <Enter>. The system displays the following information: Load File name...
Page 108
Note: The S6502 supports dual image booting, that is, usually the switch boots with the main image (i.e. the primary file), but it uses the backup image (i.e. the backup file) when the primary one is in error.
FTP. 6.3.4 Booting the Switch with Dual Images The S6502 supports dual image booting: usually the switch boots with the main image (i.e. the primary file), but it uses the backup image (i.e. the backup file) when the main image is in error.
Page 110
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance BOOT MENU 1. Download application file to flash 2. Select application file to boot 3. Display all files in flash 4. Delete file from flash 5. Modify bootrom password 0.
6.3.5 Loading Combined BOOTROM File Since the S6502 supports multiple types of cards of and these cards use different versions of BOOTROM, you are required to use the appropriate BOOTROM file when upgrading the BOOTROM of a card. The upgrading fails if the BOOTROM file does match the card.
Page 112
BOOTROM of every card by using single BOOTROM files. II. Examples of upgrading using combined BOOTROM file Predefined conditions: the SRPU on slot 0 of the S6502 is LS81P12TE; the LPU on slot 1 is LS81FT48A; the combined BOOTROM file is S6502btm.btm; the version of the host software which supports the combined BOOTROM file is S6502.app.
Page 113
[ftp] get S6502.app S6502.app [ftp] get S6502btm.btm S6502btm.btm [ftp] bye Step 2: Specify S6502.app as the application software applied by the switch during the next boot. <Quidway> boot boot-loader primary S6502.app Step 3: Reboot the switch to make the S6502.app effective.
Page 114
Installation Manual Quidway S6502 Ethernet Switch Chapter 6 Switch Monitoring and Maintenance Note: Using Boot Menu, you can only upgrade the BOOTROM of an SRPU. And use the command line if you need to upgrade the BOOTROM of the LPU.
Here takes the command line mode as an example. Predefined conditions: the card on slot 0 of the S6502 is LS81SRPUA, and its corresponding BOOTROM file is SRPUbtm.app; the card LS81FT48A is on slot 1, and its corresponding BOOTROM file is LPUbtm.app.
If loading fails when there are neither physical connection problems nor input errors, contact the local agents of Huawei Technologies for help. 6.3.7 Dealing with Lost Password Please contact the local agent of Huawei Technologies if the BOOTROM password or user password of the switch is lost. Huawei Technologies Proprietary...
Installation Manual Quidway S6502 Ethernet Switch Appendix A Lightning Protection of the Switch Appendix A Lightning Protection of the Switch A.1 Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection) Caution: Lightning arrester will not be shipped with the switch. You should purchase it by yourself if needed.
Installation Manual Quidway S6502 Ethernet Switch Appendix A Lightning Protection of the Switch Caution: Make sure that the arrester is well grounded before using the lightning arrester for power. After inserting AC power cord plug of switch into the socket of lightning arrester, if the green LED is on and the red LED does not alarm, it means that the lightning arrester of power is running and the function of lightning protection has taken effect.
Page 119
Installation Manual Quidway S6502 Ethernet Switch Appendix A Lightning Protection of the Switch Multimeter Tilted wire cutter II. Installation procedure Step 1: Tear the protection paper at one side of the double faced adhesive tape apart from the tape, and stick the tape on the surface of the arrester. Tear the protection paper at another side apart from the tape, and stick the arrester onto the chassis of the switch.
Page 120
Installation Manual Quidway S6502 Ethernet Switch Appendix A Lightning Protection of the Switch III. Installation precautions Fully consider the following items in the installation process, otherwise, the performance of the lightning arrester for network port will be affected: Lightning arrester for network port is installed in reverse direction. In practice, the “IN”...