Panasonic Micro-Imagechecker AX40 Brochure page 11

Panasonic micro-imagechecker brochure
Hide thumbs Also See for Micro-Imagechecker AX40:
Table of Contents

Advertisement

Product name
Specification
Gray scale
Max. 99/product type
Inspection
window
function
*Only when gray scale and differential processing are selected.
Shape: rectangle/polygon (3 to 16 points)/ellipse;
mask shape: rectangle/polygon/ellipse; 16
Upper and lower brightness levels can be set.
Judgment: average gray scale value
Output: average gray scale value
Gray scale
Max 99/product type
edge
*Only when gray scale and differentiation processing are selected.
Shape: line/plane
Projection/individual scan
Light to dark; dark to light; designation of both possible
Edge; leading edge and trailing edge; maximum derivative; multiple
Depth/width designation function
Judgment: number of detections
Output: number of detections/edge detection coordinate
Max. 99/product type
Smart
matching
*Only when gray scale and differentiation processing is selected.
Shape: rectangle template; mask shape: rectangle/polygon/ellipse; 16
Difference setting possible
Judgment: number of detections and number of differences
Output: number of detections/detected coordinates/detected angle/
correlation value/difference area value/number of differences
Max. 2/product type
Contour
matching
Shape: rectangle
±180 degree detection possible
Judgment: correlation
Output: detected coordinate/detected angle/correlation
Numerical computation
Max. 99/product type
4-operation computation/√
case arc/Sin/Cos/absolute value of difference
Possible to quote output of each inspection function.
Reference previous data.
Judgment output
Max. 99/product type
NOT/AND/OR/XOR/case arc
Image storage condition setting/general judgment condition setting/
output setting
Max. 50/product type
Data monitor
Data can be displayed in chart format when running.
Title input or numerical calculation results, judgment output
results, statistical results and product numbers can be quoted.
External output settings of quoted items
Upper and lower limit values of numerical computations can be
changed from the chart while running.
Statistics
Max. 16 per product type
Numerical calculation and judgment output results can be quoted.
The following can be calculated: number of scans, number of OK
results, number NG (no-go) results, OK average, OK dispersion,
max. value, min. value, and range.
Quoting is possible to the data monitor.
Operation data
Max. 4/environment
Quoting to numerical computation is possible.
Comment input is possible
Marker
Max. 8/product type
Graphic display on screen while running (rectangle/circle and
ellipse/straight lines)
/arc tangent/distance between 2 points/
10/2004
Product name
Specification
RS232C: 2 channels (max. speed 115,200 bps)
External Serial
I/O
Input: start/product type switching/camera display switching/
template re-registration/CompactFlash restore/reference of
numerical computation upper and lower limits and changes/data
storage/statistical initialization/reference and change of binarization
level/reference and change of gray scale edge threshold value
Output: judgment output and quoted data from data monitor
Computer link support: Matsushita Electric Works' FP series and
Mitsubishi's A, Q and FX series/Omron's C, CV and CS1 series/
Allen-Bradley's SLC500 series
Input: 13 points; output: 14 points; removable screw-down terminal block
Parallel
Input: start, product type switching, camera display switching,
template re-registration
Output: ready/error/flash/judgment output data
Ethernet: 1 channel
Ethernet
Output: judgment output, data quoted from data monitor (TCP/IP)
Setting data and image backup, restore, documentation of setting
data (AXTOOL)
Compact flash: 1 slot
CompactFlash
Output: judgment output and data quoted from data monitor (text file)
Setting data, image backup/restore, screen hard copy
Transparent menu
Other
Display
function
Output status monitor
Reference coordinate display (quoting to numerical computation possible)
Numerical setting of set color and center color display
Checkers with NG (no-go) results displayed with different color
Checker movement all at once is possible for each position and
Movement
at once
rotation adjustment group.
Max. 16 images/camera
Screen storage
Each time/storage possible by judgment result
Test execution possible with saved images.
Display of date saved.
Function to keep last image to be saved displayed.
White balance setting
Setting help
Focusing/aperture adjustment (only when gray scale processing is selected)
Parallel monitor
Calendar data added to saved images
Calendar
Password
Password function for moving between setting modes
11