Page 1
MANUEL de L'UTILISATEUR MANUAL del OPERADOR Cat. No. No de cat. 2420-20 12 VOLT HACKZALL™ RECIPROCATING SAW SCIE ALTERNATIVE HACKZALL™ DE 12 V SIERRA ALTERNATIVA DE 12 V HACKZALL™ TO REDUCE THE RISK OF INJURY, USER MUST READ OPERATOR'S MANUAL.
GENERAL POWER TOOL SAFETY WARNINGS WARNING READ ALL SAFETY WARNINGS AND INSTRUCTIONS. Failure to follow the warnings and instructions may result in electric shock, fi re and/or serious injury. Save all warnings and instructions for future reference The term "power tool" in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool.
If damaged, have the important information. If unreadable or missing, power tool repaired before use. Many accidents contact a MILWAUKEE service facility for a free are caused by poorly maintained power tools. replacement. • Keep cutting tools sharp and clean. Properly •...
For specifi c charg- For best performance and longest life, see your ing instructions, read the operator’s manual MILWAUKEE Electric Tool catalog or go online to supplied with your charger and battery. www.milwaukeetool.com to select the best blade for the job.
® Quik-Lok Blade Clamp Maintenance • Point the tool downward, twist the collar, and shake the tool up and down (DO NOT turn the tool • Periodically clean dust and debris from the Quik- on while your fi ngers are holding the blade clamp ®...
Fig. 5 1. Insert the blade into properly, return the tool, charger and battery pack, the tool with the teeth to a MILWAUKEE service facility for repairs. facing down. Hold the tool as shown, resting WARNING the edge of the shoe on To reduce the risk of per- the workpiece.
Page 7
Subject to certain exceptions, MILWAUKEE will repair or replace any part on a electric power tool which, after examination, is determined by MILWAUKEE to be defective in material or workmanship for a period of fi ve (5) years* after the date of purchase. Return...
Page 8
Saturate Felt (40) with lightweight oil prior to assembly with --------------- PCB Assembly Cap (41) onto Bushing (39) and Spindle (37). 28-14-0030 Gearcase Assembly 14-30-0035 Gearcase Set MILWAUKEE ELECTRIC TOOL CORPORATION --------------- Left Gearcase 13135 W. Lisbon Road, Brookfi eld, WI 53005 14-30-0925 Right Gearcase Kit Drwg. 2...
Page 9
Disassembly 3-15-25-36 Motor assembly [15] can be easily remove from gearcase assembly [25] by removing screws [3] and loosening two screws [36] from the motor ball bearing [18] area of gearbox [25] Motor Mount Alignment Pin 5 - 43 orientation to Before separating housing set [43] carefully cut thru the center of warning label [5] following the Gearcase Assembly seam of the housing halves...
Page 10
® REMOVING THE STEEL QUIK-LOK BLADE CLAMP • Remove external retaining ring (12) and pull front cam (9) off. • Pull lock pin (14) out and remove remainder of parts and discard. Outer Slot ® REASSEMBLY OF THE STEEL QUIK-LOK BLADE CLAMP •...
Need help?
Do you have a question about the 2420-20 and is the answer not in the manual?