Page 1
D5-Evo, D10 and D10 Turbo user guide LIGHT- INDUSTRIAL SLIDING GATE OPERATOR...
Page 2
A worldwide network of distributors and installers ensure that our products remain The Automatic Choice in access automation . Further information is available on our website www.centsys.com.au Centurion Systems (Pty) Ltd reserves the right to make changes to the products described in this document without notice and without obligation of Centurion Systems (Pty) Ltd to notify any persons of any such revisions or changes.
Page 5
Even if you have owned and used an automated gate before, we suggest that you read through the safety instructions below very carefully. Although years of thought have been put into every CENTSYS product – and your safety is our top priority – accidents do happen. So, please make sure that you fully understand the following safety requirements before using your automated gate.
The gearbox moulded from a high-tech engineering polymer not only looks good, but is corrosion-free and guarantees that even if you live on the coast, your D5-Evo will just keep on going. For your security, the internal gearset has a self-locking action so forced entry is no longer an option for would-be burglars.
Identification 1. D5-Evo parts identification parts Refer to the drawings below, for how to identify your D5-Evo operator and its parts. 1. D5-Evo controller 2. Courtesy light fuse (3A F/B) 3. Gate mounted origin Marker 4. Origin marker bracket 5. Origin sensor 6.
Page 9
Identification 2. D10/D10 Turbo parts identification parts Refer to the drawings below, for how to identify your D10/D10 Turbo operator and its parts. 1. D10/D10 Turbo controller 2. Courtesy light fuse (3A F/B) 3. 2 x 12V 7.2Ah battery 4. Gate mounted origin marker 5.
3. D5-Evo Manual override 3.1. Disengaging the Manual gearbox/drive Override Carefully flip to the side the camlock cover and insert the key and rotate it 90° clockwise. While holding onto the key, pull open the access door to expose the manual override thumbwheel.
4. D10/D10 Turbo Manual override 4.1. Disengaging the Manual gearbox/drive Override Flip down the lock cover and Insert the camlock key and rotate it 90° clockwise. Pull down the manual release handle to override the gearbox and allow it to be moved FIGURE 5 manually Reverse the process to re-...
FIGURE 11 5.1.2. Modes of Operation To operate the gate to open fully, the D5-Evo, D10 and D10 Turbo ave a number of operating modes to choose from depending on the application. Only one mode can be selected at any given time.
Features entrance and connected to the Closing Safety Beam input on the D5-Evo or D10/D10 Turbo to use this function, functions in order to prevent the gate from closing on people, pets or vehicles.
We highly recommend that you use protection beams if you select Condominium Mode in order to prevent the gate from closing on people, pets or vehicles. PIRAC (Beam Autoclose) (page 11) can be used with Features Condominium Mode. functions 5.1.2.4. PLC Mode This highly specialised mode is suited to industrial applications where a separate computer or programmable logic controller (PLC) is used to operate the gate.
5.1.3. Automatic closing (Autoclose Mode) The D5-Evo and the D10-D10 Turbo sliding gate operators have the facility to automatically close the gate after it has opened. When enabling this feature, the time that the gate stays open is by default fifteen seconds (this time is adjustable*).
5.1.3.2. Autoclose advanced options You can also independently set Autoclose to function when the gate is partly open, fully open or partly closed For example, disable Autoclose when the gate is partly closed to allow construction workers, gardeners, etc access to your property (although this comes with security risks).
It is possible to adjust the delay before the gate opens in one second increments from zero to 65 seconds (one minute and five seconds). The default time is two seconds It is possible to adjust the width of the pedestrian opening from a minimum of 50 millimetres to the full gate opening in ten millimetre increments.
5.1.6. PIRAC Mode (Beam Autoclose Mode) - optional This mode can only be used if a Closing Safety Beam (page 18) is fitted This mode can be used in Features Gate conjunction with any of the opening functions operating modes, Standard, Condominium and Reversing.
PIRAC Mode overridden. Your gate will stay open until you use the remote control or intercom gate release to close the gate. The D5-Evo, D10 and the D10 Turbo will then revert to normal PIRAC operation. 5.1.7. Holiday Lockout Mode This feature completely immobilises the operator and deactivates all inputs so nobody can get into your property while you are away.
5.1.9. Operator Run Profiles The D5-Evo, D10 and the D10 Turbo can be customised to your exact requirements using your LCD controller. The open and closing speeds can be independently set. Even the ramp up to full speed, ramp down to close speed and crawl distance before the gate stops can be adjusted.
5.1.10. Anti-crushing Sensitivity The D5-Evo, D10 and the D10 Turbo incorporate a sensitive electronic anti-crushing technology that activates if a person or vehicle obstructs your gate. Features The operator will respond functions differently to obstructions depending on the Operating Standard (e.g. CE, UL325) you select.
5.1.11. Infrared Safety Beam (optional but recommended) 5.1.11.1. Closing Safety Beams Closing Safety Beams provide additional protection against your gate closing on people, pets or vehicles Features If the closing beam is functions broken while the gate is opening, it will continue to open.
Status LED output Auxiliary IO (which can be used to connect to a third party alarm and security company, or a CENTSYS G-SWITCH-22 device to alert you of the alarm via SMS) It is typical to select only one of the alarm features.
5.1.13. External Gate Status Indication A LED (Light Emitting Diode) mounted on your intercom allows you to view the position of your gate and the condition of the battery and power supply features from the safety of your home. The different signals of the LED functions are described below: FIGURE 28...
5.1.14.1. Courtesy (Pillar) Light Control The Courtesy (Pillar) Lights can be switched on from inside your home or office by connecting a pushbutton to the D5-Evo, D10 or D10 Turbo controller. For your safety this pushbutton switches only low-voltage signals.
CENTSYS code-hopping receivers. However it’s also important to note that other devices cannot be activated with the new shift button, only the D5-Evo, D10 and D10 Turbo (and other CENTSYS operators that are equipped with an onboard receiver) are able to recognise the shift button signals.
5.1.16. ChronoGuard Timer (a world first) ChronoGuard™ (a world first) is a powerful multichannel timer feature which has been added to the D5-Evo, D10 and D10 Turbo controllers. A Real Time Clock and Calendar (RTC) lets you set the following features...
During any other hour, or over the weekend or public holidays, you'll have to use your CENTSYS access control device (keypad, proximity reader etc) to get in. FIGURE 35 page 24...
In the event of a power failure, energy is drawn from the battery but not replaced. Battery Low Protection will shut off the gate system to prevent running the battery flat when the battery voltage drops below: D5-Evo – 10.5 volts D10/D10 Turbo – 21 volts Features...
You will need to fit a deep-cycle low-maintenance battery (minimum 35Ah) in order to provide sufficient back-up capacity during days of poor weather. The charger supplied with the standard D5-Evo system must also be replaced with a high efficiency solar regulator.
6.3. Lightning Protection The D5-Evo, D10 and D10 Turbo controllers come standard with on- board lightning protection – but please make sure that an adequate earth is installed for this to function properly. Please contact Centurion Systems (Pty) Ltd for more information.
Check the “Mains Present” icon on the main diagnostic screen or switch to the battery charger diagnostic screen and check the charger voltage – right hand value. This should indicate, 13.8V for the D5-Evo and 27.6V for the D10 and D10 Turbo. Each charger has a red light (LED) to indicate mains supply.
8. Diagnostics Depending on the type of fault or condition of the motor, audible feedback will be given via the onboard buzzer. Listen out for this and refer to the table below: The different conditions are given in order of precedence. Break-in alarm –...
(please consult with your installer about their workmanship warranty terms and conditions). For equipment not of CENTSYS' manufacture the warranty as supplied by the original manufacturer will apply. No claims whatsoever will be recognised under the terms of this...
11. Optional extras CENTSYS infrared Safety Beams Always recommended on any gate automation installation SMARTGUARD keypad CENTSYS Cost-effective and versatile infrared safety beams keypad, allowing for access to pedestrians, armed response companies, etc. SMARTGUARD SOLO/Lattice Proximity keypad Access Control System...