Roger Access Control System
Installation guide for
PR402DR/PR402DR-BRD access controllers
Firmware version: 1.18.2 or newer
Hardware version: 1.2
Document version: Rev. C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PR402DR and is the answer not in the manual?

Questions and answers

Summary of Contents for Roger PR402DR

  • Page 1 Roger Access Control System Installation guide for PR402DR/PR402DR-BRD access controllers Firmware version: 1.18.2 or newer Hardware version: 1.2 Document version: Rev. C...
  • Page 2: Table Of Contents

    3.6.3 General purpose outputs .................... 13 3.7 RS-485 communication bus ..................... 13 3.8 Installation guidelines ..................... 13 3.9 PR402DR-BRD template in 1:1 scale ................. 13 4. Configuration ......................15 4.1 Controller address ......................15 4.2 Memory Reset procedure ....................16 4.3 Controller programming ....................
  • Page 3: Introduction

    If PR402DR and PR402DR-BRD controllers are not clearly distinguished in particular paragraph, then information specified for PR402DR is also valid for PR402DR-BRD. But if PR402DR-BRD name is used in particular paragraph then the information concerns only that specific type of controller.
  • Page 4: Description And Specification

    In case of PR402DR, the section of 35mm DIN rail is included and it can be used to fix controller in the box, which is not equipped with DIN 35mm rail.
  • Page 5: Installation

    3. I NSTALLATION 3.1 Terminals and connection diagram Fig. 1 PR402DR controller Table 2. PR402DR terminals Terminal Description Terminal Description IN8 input line 18VAC supply from transformer IN7 input line BAT- Backup battery Ground BAT+ Backup battery IN6 input line...
  • Page 6 Fig. 2 PR402DR-BRD controller Table 2. PR402DR-BRD terminals Terminal Description Terminal Description BAT+ Backup battery Ground BAT- Backup battery IN7 input line DC+AC 18VAC supply from transformer IN8 input line 18VAC supply from transformer IO1 output line REL1 relay common terminal...
  • Page 7 Fig. 3 Typical PR402DR connection diagram Page 7 of 19...
  • Page 8: Front Panel

    3.2 Front panel 3.2.1 PR402DR controller According to fig. 4, the PR402DR controller is equipped with front panel to indicate various states of the device. RESET button is available at the front panel and it can be used to restart the controller in the same way as in case of powering device off and then on.
  • Page 9: Power Supply

    Fig. 5 LEDs at PR402DR-BRD controller 3.3 Power supply The controller can be supplied from 230VAC/18VAC transformer with minimal power output 20VA and connected to AC+ and AC- terminals (“+” and “-“ polarity does not have to be observed). Alternatively, controller can be supplied with 12VDC (see fig. 6) or 24VDC (see fig. 7).
  • Page 10: Connection Of Door Lock

    Fig. 8 Connection of door lock 3.5 Connection of readers and modules Logically, PR402DR controller can operate with two access points (readers) which can provide two- way door control and are called Terminal ID0 and Terminal ID1. Terminal ID0 can be any PRT series reader configured to RACS Clock&Data mode with address ID=0 and connected to CLK/DTA...
  • Page 11: Prt Series Readers And Extension Modules

    3.5.2 Wiegand and Magstripe readers PR402DR controller can operate with various Wiegand type readers which transmit 26 to 66 bits of data in different data formats and Magstripe readers. Both types of readers be connected to...
  • Page 12: Input And Output Lines

    PR402DR controller in accordance with diagram shown in figure 10. Logically, data transmitted from the reader connected to IN1 and IN2 lines are interpreted by controller as data received from Terminal ID0 while data transmitted from the reader connected to IN3 and IN4 lines are interpreted as data received from Terminal ID1.
  • Page 13: General Purpose Outputs

    3.9 PR402DR-BRD template in 1:1 scale PCB template of PR402DR-BRD in 1:1 scale is presented in fig. 11, in order to specify mounting holes. All four holes are marked in grey. The module dimensions are 80mm x 115mm.
  • Page 14 Fig. 11 PCB template of PR402DR-BRD in 1:1 scale Page 14 of 19...
  • Page 15: Configuration

    4.1.1 Setting the address by means of jumpers The address of PR402DR controller can be set by means of jumpers – see fig. 12. Each time the new address is set, controller must be restarted (via RESET button or powering device off and on) to make new settings valid.
  • Page 16: Memory Reset Procedure

    4.1.2 Setting the address during firmware update (Fixed ID) The so called FixedID can be set during update of the controller firmware by means of Roger ISP software. Prior to firmware upload, Roger ISP software offers the possibility to set Fixed ID address in range of 00..99.
  • Page 17: Controller Programming

    RS485 bus to communication interface (UT-2, UT- 2USB, UT4 or RUD-1) and then connect the interface to PC with installed Roger ISP software. Roger ISP is available free of charge at www.roger.pl. It is not necessary to disconnect the controller from access control system, it is only required to place jumper in order to put the device in firmware download mode.
  • Page 18: Ordering Information

    · Select Erase button in Roger ISP window · Reset the device again (press RESET button or switch power off/on) · In Firmware window select firmware file (can be downloaded from www.roger.pl) and then select Program button. · After firmware upload, remove jumper from FDM contacts and reset the device.
  • Page 19 Weight of the equipment is specified in the document. Contact: Roger sp.j. 82-400 Sztum Gościszewo 59 Tel.: +48 55 272 0132 Fax: +48 55 272 0133 Tech.

This manual is also suitable for:

Pr402dr-brdPr102drPr102dr-brd

Table of Contents