IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual Page | 2 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Mobile Fire Extinguishing Equipment Date: 20.11.12 Table of contents Safety Regulations ..........................3 Labelling Fire Extinguisher 35 L......................
BEWARE OF ELECTRICAL UNITS. USE ONLY UP TO 1000 V; MINIMUM SAFETY DISTANCE 1 METER. CAUTION! IFEX TECHNOLOGIES GMBH IS NOT RESPONSIBLE FOR ANY DAMAGE TO ANIMALS, HUMAN BEINGS OR MATERIAL CAUSED BY WRONG OR IRRESPONSIBLE USE AND OPERATION OF THE IFEX 3000 IMPULSE FIRE EXTINGUISHING EQUIPMENT.
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual P a g e | 4 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Mobile Fire Extinguishing Equipment Date: 20.11.12 Labelling Fire Extinguisher 35 L...
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual P a g e | 5 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Mobile Fire Extinguishing Equipment Date: 20.11.12 Labelling Fire Extinguisher 50 L...
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual P a g e | 6 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Mobile Fire Extinguishing Equipment Date: 20.11.12 Instruction for use and operation A.
Regular training and exercise with the IFEX 3000 Impulse fire extinguishing equipment will result in maximum fire extinguishing efficiency, reducing the time needed to extinguish fires and the amount of water used.
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual P a g e | 8 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Mobile Fire Extinguishing Equipment Date: 20.11.12 1. Testing of the equipment To ensure the perfect functioning of the equipment it is required to have it tested by an expert at least once a year.
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual P a g e | 9 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Mobile Fire Extinguishing Equipment Date: 20.11.12 Testing of the trolley "Caution...
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual P a g e | 10 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Date: 20.11.12 Mobile Fire Extinguishing Equipment Reminder: 1. All couplings, threads and other parts of the extinguishing unit need to be checked for cleanliness, and cleaned if necessary! 2.
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual P a g e | 11 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Mobile Fire Extinguishing Equipment Date: 20.11.12 Air pressure cylinder 6.1 The air pressure cylinder needs to be checked for:...
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual P a g e | 12 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Mobile Fire Extinguishing Equipment Date: 20.11.12 Filling Instructions Filling of the fire extinguishing agent: 7.1 IFEX 3035 mobile fire extinguishing equipment = 35 L container:...
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual P a g e | 13 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Mobile Fire Extinguishing Equipment Date: 20.11.12 Getting the unit ready for use Make sure the fire extinguishing agent container and the air pressure cylinder are filled according to para 7.1, 7.2 and 7.3.
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual P a g e | 14 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Mobile Fire Extinguishing Equipment Date: 20.11.12 Machinery and tools for maintenance The following list of tools is separate from the instructions.
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Instruction Manual P a g e | 15 Instructions for Use and Operation IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Mobile Fire Extinguishing Equipment Date: 20.11.12 Maintenance and test certification for Trolley IFEX 3035 and IFEX 3050...
Safety valve 1/4"-6 bar IF-BP-300002-3B Description and type Art.-n° IFEX Code Oty. Pos. Drawing-n° Dimensions with out Scale IFEX Technologies GmbH Surface Hansestraße 18 tolerances acc. acc. D-27419 S ittensen IF-3000 DIN 71 68-m DIN ISO 1 302 IFEX Code:...
IFEX Technologies GmbH IFEX 3000 Impulse Fire Fighting Technology Nr.:IF3000-100 Appendix A Instruction Manual Instructions for Use and Operation P a g e | 1 IFEX 3035 and IFEX 3050 Hansestr.18 D-27419 Sittensen Date: 20.11.12 Mobile Fire Extinguishing Equipment Appendix A 1.
Not advisible. We will notify the appropriate No problem, if faults are adjusted. authority. ,Date (Place) Next regular pressure test _____________ Expert IFEX 3000 Impulse Technology Nr.: IF3000-100 IFEX Appendix A Technologies Directive 2009/104/EC GmbH Page: Hansestr. 18 Extinguishing agent container 35 l D-27419 Sittensen Date: 20.11.12...
Not advisible. We will notify the appropriate No problem, if faults are adjusted. authority. ,Date (Place) Next regular pressure test _____________ Expert IFEX 3000 Impulse Technology Nr.: IF3000-100 IFEX Appendix A Technologies Directive 2009/104/EC GmbH Page: Hansestr.18 Extinguishing agent container 50 l D-27419 Sittensen Date: 20.11.12...
Not advisible. We will notify the appropriate No problem, if faults are adjusted. authority. ,Date (Place) Next regular pressure test _____________ Expert IFEX 3000 Impulse Technology Nr.: IF3000-100 IFEX Appendix A Technologies GmbH Directive 2009/104/EC Hansestr. 18 Page: D-27419 Sittensen Gun air power chamber Date: 20.11.12...
Page 27
After consulting IFEX Technologies GmbH the customer should return the defective product to IFEX Technologies GmbH. In the event of a warranty claim IFEX Technologies GmbH will pay the costs for the resulting labour and any required materials or replacement parts.
Page 28
Any other circumstances for which IFEX Technologies cannot be held responsible. The warranty is rendered null and void if: IFEX Technologies products are operated or fitted with parts, components or peripherals which have not been approved for that purpose by IFEX Technologies GmbH.
Page 29
Typ IFEX 3035 and IFEX 3050 ATTENTION! ANY UNAUTHORIZED ALTERATION TO THE EQUIPMENT WOULD RESULT IN LOSS OF APPROVAL AS WELL IN LOSS OF GUARANTEE! IFEX Technologies GmbH, Hansestr.18, D-27419 Sittensen Telephone: +49 (0) 4282 93060 Fax: +49 (0) 4282 93026 Homepage: www.ifextechnologies.com e-mail: info@ifextechnologies.com...
Need help?
Do you have a question about the IFEX 3000 and is the answer not in the manual?
Questions and answers