  • Page 1 TPOne-RF Electronic Programmable Room Thermostat Installation Guide Danfoss Heating...
  • Page 2 The full text of the EU declaration of conformity is available at the following internet address, http://heating.danfoss.co.uk/download/documentation/ Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies.
  • Page 3: Installation Instructions

    An electronic room thermostat that controls Product both thermostat cycle rate and in-cycle on/ Class off ratio of the heater proportional to room temperature. TPI control strategy reduces mean water temperature, improves room temperature control accuracy and enhances system efficiency. Danfoss Heating...
  • Page 4 Mounting Thermostat or Remote Room Sensor positioning: Please note: This product should only be installed by a qualified electrician or competent heating installer and should be in accordance with the local wiring regulations. TPOne-RF...
  • Page 5 Remote room or limit sensor Window switch contact NOTE: Remote Sensor to be wired with 1mm 2 core double insulated cable only. Cable length should not exceed 10 metres. Sensor cable should NOT be run parallel to mains cable. Danfoss Heating...
  • Page 6: User Interface

    User Interface Comfort modes Navigation Display Comfort Modes Heating made easy: TPOne Comfort Modes simplify the way you plan your heating day to day. You define your comfort modes in the user schedule and manually override when you need, allowing you to adapt your schedule to the way you live.
  • Page 7: Comfort Modes

    Note: the standby option places the heating control in standby only, if Hot Water is set up this is not affected. To switch Hot Water control off see User Menu > Hot Water > Mode Danfoss Heating...
  • Page 8 Navigation Press Menu to access the intuitive text menu. The common feature User Menu will be displayed first. Additional settings can found Menu in the User Setting option and more advance settings can be found in the Installer Setting option. Press OK to select menu options or confirm Select / settings.
  • Page 9 TPOne-RF and receiver. NOTE: TPOne monitors several conditions and will provide warning or information messages when necessary. Details on these can be found on pages 24 - 26. Danfoss Heating...
  • Page 10: Setup Wizard

    Setup Wizard The setup wizard will run when power is first applied to the TPOne. Once set the further changes can be made in the user and installer setting menus. Language English   Set Date   04 - 02 - 2016  ...
  • Page 11: Set Temperatures

    See page 22 for default temperatures 10:45 Thurs User Menu  Temperatures   Temperatures      Home AM - 21. Home PM - 22.  Away - 16. Asleep - 12.  User Menu  Temperatures    Danfoss Heating...
  • Page 12: Setup Schedule

    Setup Schedule Follow this routine to set Heating Schedule. Days can be set individually or grouped and options for weekdays and weekend settings can be selected. All day combinations can then have one, two or three Home Periods selected. TPOne will automatically fill in the gaps with Away and Asleep Periods depending on the time of the day.
  • Page 13 Home Period - 1 From 08.30 06.00  Home Period - 2 From 13.30 12.30  Home Period - 3 From 17.30 22.30  Sechedule - Heating Your heating schedule  has been saved User Menu  Schedule    Danfoss Heating...
  • Page 14 User Menu Click & Save Click & Save is an easy access saving function. Switching Click & Save ON will reduce the user set comfort temperatures by 1°C. Switching Click & Save OFF will return TPOne to the user set comfort temperatures.
  • Page 15 Enter start and end date of your holiday and the required energy saving home temperature. Danfoss Heating...
  • Page 16: User Settings

    User Settings Set Date Option to set the current date. Note: if batteries are removed or have expired for more than 2mins a startup wizard will prompt for date to be reset. Set Time Option to set the current time and 12 or 24hr clock setting.
  • Page 17: Installer Settings

    The thermostat then calculates how soon before the required time the heating is turned up. Optimised Start in TPOne is dynamic and will adjust automatically to the home heating characteristics to reach required temperature at the required time. Default: Normal Danfoss Heating...
  • Page 18 Installer Settings (Continued) Temperature This allows the upper and lower temperature of Limits the thermostat setting range to be limited. Defaults: Minimum 5°C, Maximum 35°C Frost Protect To help protect against damage to the heating system caused by extreme low temperatures the TPOne includes a Frost Protect level.
  • Page 19 None - No external sensor fitted Room Sensor - Remote room sensor fitted. This will take priority over the TPOne internal sensing. Danfoss part TS2A - sold seperately Window Sensor - Where a window sensor has been fitted the TPOne will go into standby mode while the window is open.
  • Page 20 Installer Settings (Continued) Service TPOne incorporates a service interval timer where Interval a service due date for the boiler can be set. The service interval timer is passcode protected and must only be set by a qualified heating installation engineer. The installer can set the service due date and select from one of four service due restriction modes: 1 - Warning Only - visual and audible warnings...
  • Page 21: Service Interval

    - The installer may cancel or reset the service interval timer as part of the boiler service. - This is a gas safety feature that can only be accessed by a qualified heating installation engineer. *Gas Safety Regulations may vary according to region Danfoss Heating...
  • Page 22: Default Tables

    Default tables SCHEDULE DEFAULTS 06:30 - 08:30 06:30 - 08:30 (Weekend (Weekend 07:30 - 09:30) 07:30 - 09:30) 06:30 - 22:30 (Weekend 07:30 - 22:30) 11:30 - 13:30 16:30 - 22:30 16:30 - 22:30 TPOne-RF...
  • Page 23 Default tables (Continued) TEMPERTURE DEFAULTS 20°C 20°C 15°C 15°C Danfoss Heating...
  • Page 24 Information TPOne will show information related to current operation, these messages will be shown at the top of the display. Information messages will be displayed while the operation is active and will automatically reset when operation is completed Window This will be displayed where a window open Open switch has been fitted and the window is opened.
  • Page 25 Low Heat If set mode temperature is not reached within 2 hours then TPOne will warn of Low Heat. The heating system should be checked to confirm it is operating correctly Danfoss Heating...
  • Page 26 Warnings (continued) Service Due Where the TPOne Service Interval timer has been set this warning will be shown when the timer has expired. Contact the property owner or landlord to arrange the boiler safety mainantance. see page 21 Heat Where the TPOne Service Interval timer has been Reduced set this warning will show after the timer has expired and will indicate that heating has been...
  • Page 27 Danfoss Heating...
  • Page 28 Danfoss Ltd. Ampthill Road Bedford MK42 9ER Tel: 01234 364621 Fax: 01234 219705 Email: ukheating@danfoss.com Website: www.heating.danfoss.co.uk © Danfoss HS | 02/2016 | VIHSJ102...