Alignment and Adjustmens
- Paper Jam at the paper exit area
There is a paper at exit area
After cover Open , Paper must be removed, and then close the cover
- Motor Lock Error
Motor does not run or runs abnormal speed
Motor or Main board must be checked
- LSU Motor Lock Error
LSU motor does not run or runs abnormal speed
Hsync is not detected
LSU or Main board must be checked
- Transfer Belt Error
ITB home sensor is not checked for a normal time
ITB must be checked
- Fuser Over Heat error
Temperature of fuser is high
Fuser or Main board must be checked
- Fuser Low Heat error
Temperature of fuser is low
Fuser or Main board must be checked
- Dev. Home error
Home of Development is not checked or checked at the abnormal time
Clutch of Development or Main board must be checked
- ADC not Confirm Error
Signal of confirmation for ADC is not detected
Main board must be checked