controller BITS output applique
To configure the Building Integrated Timing Supply (BITS) clock output link type and characteristics,
use the controller BITS output applique command in global configuration mode. To remove the
configuration, use the no form of this command.
Syntax Description
E1 2048 KHz
E1 framing
linecode (E1)
T1 framing
linecode (T1)
line-build-out
Command Default
The default output timing is E1.
Command Modes
Global configuration
OL-28238-01
controller BITS output applique E1{2048KHz | framing {fas_crc4 | fas_nocrc | |mfas_crc4 |
mfas_nocre} linecode {ami | hdb3}
controller BITS output applique T1 framing {d4 | esf} linecode {ami | b8zs} line-build-out
{0-133ft | 133-266ft | 266-399ft | 399-533ft | 533-655ft}
no controller BITS output applique
Specifies an EI timing signal input of 2048 KHz.
Specifies an EI signal input and specify the framing mode as one of these
options:
•
•
•
•
Selects the E1 line coding:
•
•
Specifies a T1 (1.544 MHz) signal input and specify the framing mode as one
of these options:
•
•
Selects the T1 line coding:
•
•
Selects a line length:
•
•
•
•
•
fas_crc4—FASCRC4
fas_nocrc—FAS
mfas_crc4—MFASCRC4
mfas_nocre—MFAS
ami—AMI encoding
hdb3—HDB3 encoding
d4—D4
esf—Extended Superframe
ami—AMI encoding
b8zs—B8ZS encoding
0-133ft
133-266ft
266-399ft
399-533ft
533-655ft
Cisco ME 3800X and ME 3600X Switch Command Reference