8-5 Simple Relative Measurements using CW Display

8-5 Simple Relative Measurements using CW Display
The operations for relative measurements are described in the following steps.
1. From the
CW
pressing the
Clear Reference
2. Connect the first DUT (device under test).
3. Save the measurement result of the first DUT by pressing the
key.
4. As shown in
Figure
reference window and converts the main measurement window to display the difference
between the current measurement and the saved reference. In other words, saving a
reference will normalize the results to the current measurement. When relative
measurements are displayed, REL is indicated in the main measurement window.
Figure 8-5. Continuous Wave Menu with Relative Measurements
5. Connect the second DUT and view the difference between the first and second DUT
measurements.
6. To create a new reference, press the
soft key
Reference
This completes the procedure for relative measurements.