Installation
Instructions
"If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: GEAppliances.com"
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT
for local inspector's use.
IMPORTANT
codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions
for future reference.
• Skill level – Installation of this vent hood
requires basic mechanical and electrical skills.
• Completion time –
Approximately
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation is
not covered under the Warranty.
CAUTION:
Due to the weight and size of
these vent hoods and to reduce the risk of
personal injury or damage to the product, TWO
PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
FOR YOUR SAFETY:
WARNING:
Before beginning the
installation, switch power off at service panel and
lock the service disconnecting means to prevent
power from being switched on accidentally.
When the service disconnecting means cannot
be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
Glass Wall
Chimney Vent Hoods
PVW7301, PVW7361
Save these instructions
Observe all governing
1 to 3 hours
WARNING:
OF FIRE, ELECTRIC SHOCK OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring
must be done by qualified person(s) in
accordance with all applicable codes and
standards, including fire-rated construction.
B. Sufficient air is needed for proper
combustion and exhausting of gases
through the flue (chimney) of fuel burning
equipment to prevent back drafting. Follow
the heating equipment manufacturer's
guidelines and safety standards such
as those published by the National Fire
Protection Association (NFPA), the
American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE)
and the local code authorities.
C. When cutting or drilling into wall or ceiling,
do not damage electrical wiring and other
hidden utilities.
D. Ducted fans must always be vented to the
outdoors.
E. Turn off breaker to adjacent rooms while
working.
WARNING:
OF FIRE, USE ONLY METAL DUCT WORK.
(991.0364.613 rev 2) 31-11007-1 10-15 GE
TO REDUCE THE RISK
TO REDUCE THE RISK

Advertisement

Table of Contents
loading

Summary of Contents for GE PVW7361

  • Page 1 Installation Glass Wall Chimney Vent Hoods Instructions PVW7301, PVW7361 “If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: GEAppliances.com” BEFORE YOU BEGIN WARNING: TO REDUCE THE RISK Read these instructions completely and OF FIRE, ELECTRIC SHOCK OR INJURY TO carefully.
  • Page 2: Product Dimensions

    Installation Preparation PRODUCT DIMENSIONS INSTALLATION CLEARANCES These vent hoods are designed to be installed onto a wall with no above cabinets. 2-9/16” 4-15/16” • Install these hoods between the 24” required 10-1/4” minimum and 36” recommended maximum 4-15/16” above the cooking surface. 11-13/16”...
  • Page 3: Advance Planning

    Installation Preparation ADVANCE PLANNING POWER SUPPLY Duct Install Planning IMPORTANT – (Please read carefully) • This hood is designed to be vented vertically WARNING: through the ceiling. Use a 6" round duct. Use FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE locally supplied elbows to vent horizontally PROPERLY GROUNDED.
  • Page 4 Installation Preparation TOOLS AND MATERIALS REQUIRED PLAN THE INSTALLATION (NOT SUPPLIED) CAUTION: To reduce risk of fire and to properly exhaust air, be sure to duct the air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, Safety glasses or garages.
  • Page 5: Installation Dimensions

    Installation Preparation RANGE HOOD COMPONENTS INSTALLATION DIMENSIONS The Glass Chimney Hoods are adjustable and A. Canopy Section H. Mounting Bracket designed to meet varying ceiling heights. The duct B. Upper Duct Cover I. Washers covers can be adjusted for ceilings between C.
  • Page 6: Prepare The Wall

    Installation Preparation PREPARE THE WALL Duct Covers and Power Supply Hood Body 1. Place one of the duct cover brackets against the wall so that its top edge is 1/16” from the 1. Put a protective covering over the surface below ceiling and level.
  • Page 7: Prepare Hood For Installation

    Installation Instructions PREPARE HOOD FOR INSTALLATION 3. Fit the recirculation duct with extensions over the vent exhaust outlet and push down to seat Remove the grease filter from the unit and set on outlet. Attach the vertical duct work to the aside.
  • Page 8: Finish The Installation

    Installation Instructions MOUNT THE GLASS RANGE HOOD FINISH THE INSTALLATION (Continued) 1. Ducted installation only: Connect the house ducting to the damper on the hood body. Seal 4. Remove the top duct cover bracket from the wall. all connections with duct tape. 5.
  • Page 9: Antes De Comenzar

    Instrucciones Pared de Vidrio Campanas de Ventilación de la Chimenea de instalación PVW7301, PVW7361 ¿Preguntas? Llame al 800.GE.CARES (800.432.2737) o visite nuestro sitio Web en: GEAppliances.com ANTES DE COMENZAR ADVERTENCIA: PARA REDUCIR EL Lea estas instrucciones por completo y con RIESGO DE INCENDIO, DESCARGA ELÉCTRICA...
  • Page 10: Dimensiones Del Producto

    Preparación para la instalación DIMENSIONES DEL PRODUCTO ESPACIO DE INSTALACIÓN Estas campanas de ventilación están diseñadas para ser instaladas en una pared sin gabinetes 2-9/16” 4-15/16” superiores. 10-1/4” 4-15/16” • Instale estas campanas entre el mínimo requerido de 24” y el máximo recomendado de 11-13/16”...
  • Page 11: Planificación Previa

    Preparación para la instalación PLANIFICACIÓN PREVIA SUMINISTRO DE ENERGÍA Planificación para la Instalación con Conducto IMPORTANTE – (Tenga a bien leer cuidadosamente) • Esta campana está diseñada para ventilarse ADVERTENCIA: en forma vertical a través del cielorraso. Use un conducto circular de 6”. Utilice codos PARA SEGURIDAD PERSONAL, ESTE APARATO suministrados en forma local para ventilación DEBE CONECTARSE A TIERRA DE MANERA...
  • Page 12: Herramientas Y Materiales Requeridos

    Preparación para la instalación HERRAMIENTAS Y MATERIALES PLAN DE INSTALACIÓN REQUERIDOS (NO SUMINISTRADOS) PRECAUCIÓN: A fin de reducir riesgos de incendios y para que el aire salga de forma apropiada, asegúrese de que el aire sea conducido hacia fuera - No ventile el aire de la Gafas de seguridad salida hacia espacios dentro de paredes o cielorrasos o áticos, espacios muy bajos o garajes.
  • Page 13: Dimensiones De Instalación

    Preparación para la instalación COMPONENTES DE LA CAMPANA DIMENSIONES DE INSTALACIÓN EXTRACTORA Las Campanas con Chimenea de Vidrio son ajustables y están diseñadas para adaptarse a A. Sección de la Base H. Soporte de Montaje diferentes alturas de cielorraso. Las cubiertas de los B.
  • Page 14 Preparación para la instalación PREPARE LA PARED Cubiertas de Conductos y Suministro de Corriente Cuerpo de la Campana 1. Coloque uno de los soportes de la cubierta del 1. Coloque una cubierta protectora sobre la superficie conducto contra la pared, de modo que su extremo debajo de la ubicación de la campana, a fin de proteger superior esté...
  • Page 15 Instrucciones de instalación PREPARE LA CAMPANA PARA SU 3. Inserte el conducto de recirculación con extensiones INSTALACIÓN sobre la salida del escape de ventilación y empuje hacia abajo para que coincida con la salida. Adhiera Retire el filtro de grasa de la unidad y deje el mismo el conducto vertical a la parte superior de la a un lado.
  • Page 16: Finalice La Instalación

    Instrucciones de instalación MONTE LA CAMPANA EXTRACTORA FINALICE LA INSTALACIÓN DE VIDRIO (continúa) 1. Instalación con conducto únicamente: Conecte el conducto hogareño al regulador del cuerpo de la 4. Retire de la pared el soporte superior de la cubierta del campana.

This manual is also suitable for:

Pvw7301

Table of Contents