  • Page 1 DOMIcondens F 28 INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE Supplied By www.heating spares.co Tel. 0161 620 6677...
  • Page 2: General Instructions

    Dear Customer, drain just the DHW circuit and add a suitable antifreeze to the heating system, DOMIcondens F 28 is a high-efficiency sealed chamber condensing heat generator for complying with that prescribed in sec. 3.3. heating and hot water production running on natural gas or LPG, and equipped with a 2.4 Adjustments...
  • Page 3 DOMIcondens F 28 Adjustments from Remote Timer Control 3.2 Place of installation If the Remote Timer Control (optional) is connected to the boiler, the above ad- The combustion circuit is sealed with respect to the place of installation room, therefore justments are managed according to that given in table 1.
  • Page 4 9 - Accessing the terminal block Water treatment 3.6 Fume ducts If water treatment is necessary, Ferroli recommends the exclusive use of specific prod- Important ucts such as Fernox or Sentinel to be applied according to the producer's instructions.
  • Page 5: Side Outlet

    DOMIcondens F 28 Baffles Connection with separate pipes Boiler operation requires fitting the baffles supplied with the unit, according to that given in the following tables. Before inserting the fume exhaust pipe, check the presence of the right baffle (when it is to be used) and that it is correctly positioned.
  • Page 6: Service And Maintenance

    DOMIcondens F 28 4. SERVICE AND MAINTENANCE 4.1 Adjustments Gas conversion The unit can operate on natural gas or LPG and is factory-set for use with one of these two gases, as clearly shown on the packing and on the dataplate. Whenever a different...
  • Page 7 DOMIcondens F 28 Checks during operation Table of faults • Switch the unit on. • Check the tightness of the fuel circuit and water systems. Table. 5 - Fault list • Check the efficiency of the flue and air/fume ducts while the boiler is working.
  • Page 8 DOMIcondens F 28 5. TECHNICAL DATA AND CHARACTERISTICS Data Unit DOMIcondens F 28 Max. heating capacity 27.2 Min. heating capacity 10.0 Max. Heat Output in heating (80/60°C) 26.2 Min. Heat Output in heating (80/60°C) Max. Heat Output in heating (50/30°C) 28.2...
  • Page 9 DOMIcondens F 28 DBM02.1B 230V 50 Hz 22:00 REMOVE TO CONNECT CLOCK fig. 21 - Wiring diagram cod. 3540S920 - 05/2009 (Rev. 00) Supplied By www.heating spares.co Tel. 0161 620 6677...
  • Page 10: Gas Boiler Commissioning Checklist

    2 6 7 BENCHMARK No. BENCHMARK Please add the first 4 digits of the Boiler serial No to complete the BENCHMARK No. GAS BOILER COMMISSIONING CHECKLIST C O L L E C T I V E M A R K BOILER SERIAL No.
  • Page 11: Service Interval Record

    ENGINEER NAME ENGINEER NAME COMPANY NAME COMPANY NAME TEL No. TEL No. CORGI ID CARD SERIAL No. CORGI ID CARD SERIAL No. COMMENTS COMMENTS SIGNATURE SIGNATURE FERROLI TECHNICAL HELPLINE - 08707 282 885 Supplied By www.heating spares.co Tel. 0161 620 6677...
  • Page 12 Should you require any assistance during the installation call our Technical Service Helpline on 08707 282 885 option 1 Should you require a service engineer to visit call our service centre on 08707 282 885 option 2 Phone numbers: Installer Service Engineer BECAUSE OF OUR CONSTANT ENDEAVOUR FOR IMPROVEMENT DETAILS MAY VARY SLIGHTLY FROM THOSE QUOTED IN THESE INSTRUCTIONS.