Gibertini densimat Instruction Manual

Hydrostatic balance

Advertisement

INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
DensiMat
INSTRUCTION MANUAL
Hydrostatic Balance
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the densimat and is the answer not in the manual?

Questions and answers

Summary of Contents for Gibertini densimat

  • Page 1 INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL DensiMat INSTRUCTION MANUAL Hydrostatic Balance INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL...
  • Page 2: Table Of Contents

    BEHAVIOUR OF THE INSTRUMENT WHEN SWITCHING ON AND CONDITIONS FOR OPTIMAL MEASUREMENTS ..................11 APPENDIX A: LIST OF PRINCIPAL MESSAGES DISPLAYED ........13 APPENDIX B: POSSIBLE OPTIONS FROM DENSIMAT KEYBOARD......14 APPENDIX C: USE OF THE CYLINDER FOR MEASUREMENTS IN CONTINUOUS ..15 INSTALLATION .......................15 OPERATING INSTRUCTION...................16...
  • Page 3: Important Warnings

    11. Always clean the instrument after use to avoid subsequent inaccuracies and/or damage to the equipment. 12. Gibertini Elettronica s.r.l. does not accept any legal liability for damages or other consequences due to mishandling of the instrument or its accessories.
  • Page 4: General Description And Technical Characteristics

    ENGLISH DensiMat 2. GENERAL DESCRIPTION AND TECHNICAL CHARACTERISTICS The instrument consists of an electronic hydrostatic balance DENSIMAT, with a sensitivity of fifth decimal points. GENERAL SPECIFICATIONS ≥ 15 minutes Warm-up time +15°C / +30°C Operating temperature RS232 I/O Data output...
  • Page 5: Installation

    Institutes such as the L.N.E. of Paris, the I.M.G.C. of Turin, the PTB in Germany etc. 3. INSTALLATION Densimat was designed and made to resist and to function even under difficult conditions. However, it is advisable to install Densimat: on a rigid support without vibrations in a stable room temperature and without excessive ventilation utilizing a separate electrical supply.
  • Page 6 Connect the circular socket of the transformer (fig. 3 n. 6) to the connector of Densimat (fig. 3 n. 3) keeping the flat side of pin upwards. Connect the transformer to the socket (fig. 3 n. 5) of the electric mains.
  • Page 7: Densimat Keyboard

    DensiMat 3.2 DENSIMAT KEYBOARD The Densimat keyboard (fig. 4) has two displays and three keys. On the left display it appears the temperature read by thermo probe; on the right display it appears: a. specific gravity, with the parameters of standard functioning;...
  • Page 8: Determination Of Specific Gravity D 20/20 Of A Liquid

    6. once 20°C has been reached (left display) the reading is carried out: e.g. 0.98480 Figure 6 1. Knob to adjust the cylinder position 2. Centering plate For this scope a thermostatic bath (manufactured by Gibertini Elettronica), where the vessel containing the liquid under examination is be put, is useful. - 8 -...
  • Page 9: Determination Of The Density Of A Liquid At 20°C

    4.2 DETERMINATION OF THE DENSITY OF A LIQUID AT 20°C To calculate the density of a liquid at 20 °C multiply its specific gravity d read by 20/20 the Densimat by the density of the water at 20 °C, that is: liq x 0,998203 20/20 - 9 -...
  • Page 10: Compensation Of Floater In Use

    "Compensation" occurs by modifying from the keyboard the answer of the Densimat in standard conditions controlling the correspondence between read value and theoretical value.
  • Page 11: Behaviour Of The Instrument When Switching On And Conditions For Optimal Measurements

    5. BEHAVIOUR OF THE INSTRUMENT WHEN SWITCHING ON AND CONDITIONS FOR OPTIMAL MEASUREMENTS At the moment when Densimat is switched on, the following message appears on the right display: d x – x x where X-XX are the numerical values that indicate the installed release on instrument, giving therefore an useful indication for technical service if it is necessary.
  • Page 12 During the calibration cannot be use the instrument. At the moment of switching on of the Densimat a period of ten minutes of thermal stabilization is needed during which the instrument carries out automatically a calibration each minute and, even if possible, it is not advisable to carry out measurements.
  • Page 13: Appendix A: List Of Principal Messages Displayed

    ENGLISH DensiMat 6. APPENDIX A: LIST OF PRINCIPAL MESSAGES DISPLAYED The fixed messages warn the operator that some process is in progress. No intervention is needed. flashing messages warn an anomalous condition or they ask for an intervention of the operator.
  • Page 14: Appendix B: Possible Options From Densimat Keyboard

    ENGLISH DensiMat 7. APPENDIX B: POSSIBLE OPTIONS FROM DENSIMAT KEYBOARD Pressing the key MODE it enters in following options: CorrP CorrC LuLd and that it shows in order pressing repeatedly the key MODE. To activate one of them press the key " + ". To return to operative mode press the key " - ".
  • Page 15: Appendix C: Use Of The Cylinder For Measurements In Continuous

    ENGLISH DensiMat NOTE: if the Densimat stops working because of an incorrect manoeuvre on the keyboards, remove the plug and connect it again in the socket keeping pressed the key " + ". As soon as the instrument is switched on again the following...
  • Page 16: Operating Instruction

    ENGLISH DensiMat Fix the cylinder on the Densimat with the spring as shown in figure 8. Connect the tubes to the cylinder for measurements in continuo. Insert into the inside of the cylinder the appropriate " net to break bubbles ", pushing it to the bottom.
  • Page 17: Appendix D: Reference To Legal Metrology

    The check must be carried out at least 1 hour after the switching on of the instrument using certified masses in E2 class. Press the key "MODE" on Densimat until the display shows "PAr" and confirm with the key " + "; the display shows "P0=00".
  • Page 18 " that involve the obligation of CE seal (art. 2 subsection 2 letter a) of the EEC 90/384 Directive acknowledged with the Legislative Decree 517/92). The mod. Densimat hydrostatic balances are sealed " CE ": the Metric Central Office of Rome has issued an approval certificate CE of the type n. the 96-011, in virtue of this the Gibertini company provides the affixing of the nameplate "...
  • Page 19: Disposal - Information For Users

    ENGLISH DensiMat 10. DISPOSAL – INFORMATION FOR USERS According to the 2002/95/CE, 2002/96/CE and 2003/108/CE Directives, concerning the reduction in the use of hazardous substances in electrical and electronic apparatus, as well as the disposal of waste materials The symbol of a crossed box applied on the apparatus or on the packaging indicates that the product must be collected separately from other waste materials at the end of its useful life.

Table of Contents