9.2.
Disassembly and Assembly Procedure for the Lens (H-HS12035)
It is recommended dealing with Clean box, to keep maintaining the dustproof environment.
(Refer to "8.2. Clean Box" section of this service manual for details.)
Important:
1. When servicing the enclosure part (refer to Fig. X1), it must be performed inside of specified clean level.
(Specified clean level: Less than class 10,000 (Federal Standard 209D))
As for procedure, refer to the "11 Maintenance" for details.
2. To minimize the possibilities/risk of getting the dust/dirt on the lens surface, keep covering the lens unit with lens caps (front &
rear), other than necessary cases.
3. Do not touch the surface of the lens glasses with your fingers.
4. Blow off the dust on the surface of the lens with a blower brush.
5. 5th lens has the "Nano Surface Coating".
Avoid damage the coating, please DO NOT clean it with cloth.
Please keep cleaning 5th lens, blow off the dust with air brush.
Proceed disassemble and assemble, by referring the following table Fig. X1.
NOTE:
1. When tightening screws, use a torque driver (RFKZ0456) with specified torque mentioned in each step.
55
Need help?
Do you have a question about the DMC-GH3P and is the answer not in the manual?