Hydraulic System Maintenance; Checking The Hydraulic Oil Level; Changing The Hydraulic System Filter And Oil - Toro TITAN ZX 5400 Operator's Manual

Zero-turn-radius riding mower
Hide thumbs Also See for TITAN ZX 5400:
Table of Contents

Advertisement

Hydraulic System
Maintenance
Hydraulic System Oil Specification
Oil Type: Toro HYPR-OIL® 500 or 20w-50 motor oil.
System Capacity: approximately 4.495 liter (152 oz) with a
filter change.
Important: Use oil specified or equivalent. Other fluids
could cause system damage.
Checking the Hydraulic Oil
Level
Service Interval: Every 25 hours
Check expansion reservoir and if necessary add oil to the
FULL COLD line.
3
Figure 58
1. Expansion reservoir
2. Full Cold line
Changing the Hydraulic
System Filter and Oil
The filter and oil are changed at the same time. Do Not reuse
oil. Once the new filter is installed and oil is added any air in
the system must be purged.
The bleeding process is repeated until the oil remains at the
FULL COLD line in the reservoir after purging. Failure to
properly perform this procedure can result in irreparable
damage to the transaxle drive system.
1
2
G010253
3. Engine
Removing Hydraulic System Filters
Important: When the hydraulic oil filter is removed, all
of the hydraulic oil in each transaxle will drain out. Use
a container that will handle 4.495 liters (152 oz) or larger.
1. Stop engine, wait for all moving parts to stop, and
allow engine to cool. Remove the key and engage the
parking brake.
2. Locate the filter and guards on each transaxle drive
system
(Figure
59). Remove three screws securing the
filter guard and guard.
5
3
Right side shown
1. Transaxle drive
2. Oil filter
3. Filter guard
3. Carefully clean the area around the filters. It is
important that no dirt or contamination enter the
hydraulic system.
4. Place a container below the filter to catch the oil that
drains when the filter and vent plugs are removed.
5. Locate and remove the vent plug on each transmission
6. Unscrew the filter to remove and allow oil to drain
from the drive system.
Repeat this procedure for both filters.
Installing the Hydraulic System Filters
Service Interval: After the first 50 hours
Every 400 hours
40
G010254
4
Figure 59
4. Screws
5. Vent plug
1
2

Hide quick links: