Page 1
User’s manual PLEASE READ THE USER’S USE ONLY AS DIRECTED MANUAL CAREFULLY BEFORE If symptoms persist, consult USING THIS PRODUCT your Health Care Professional Model number: RIX 1718_IFU01_7244012.indd 1 27/03/2015 10:04...
Warnings, Cautions and Adverse Reactions Instructions for use How long should I use REVITIVE? Step 1: Setting up REVITIVE for the first time Step 2: Setting up REVITIVE for use Step 3: Using the foot pads Step 4: Using the body pads...
What is inside the box? Upon opening the carton, please check that the following components are provided. If you think anything is missing, contact us toll-free on our 877-260-3114 or visit www.revitive.com helpline number Body pads x 2 Pairs AC/DC power adapter...
Parts and Controls of REVITIVE Parts of REVITIVE Carry handle Control panel/display Power ON/OFF Foot pads AC/DC power adapter socket Body pad sockets IsoRocker Controls of REVITIVE Time control – /+ Foot pad intensity control – /+ Body pad intensity control – /+...
You can choose to enable or disable the IsoRocker anytime. REVITIVE is designed to be easy to use and also comes with a remote control, which means you do not have to reach down to adjust settings during use.
IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USE WHO SHOULD NOT USE REVITIVE REVITIVE should not be used by some people. Do not use if: (contraindications) • You have a cardiac pacemaker, implanted defibrillator, or other implanted metallic or electronic device because this may cause electric shock, burns, electrical interference, or death •...
Page 8
• on reproductive organs When Not to Use REVITIVE There are times you should not use REVITIVE. Do not use REVITIVE: • with electronic monitoring equipment (such as cardiac monitors, ECG alarms), which may not operate properly when the electrical stimulation device is in use.
Page 9
– use a low intensity and shorter time to avoid over-stimulation or muscle fatigue. • It is possible REVITIVE may reduce the sensation of pain that would normally act as a warning of an underlying problem. •...
In the unlikely event your REVITIVE malfunctions, disconnect it from the power source and contact your nearest authorized agent. • The REVITIVE has passed the required tests for EMI, it may still be affected by excessive emissions and/or may interfere with more sensitive equipment. •...
Instructions for use How long should I use REVITIVE? Do not use REVITIVE more than 6 sessions of 30 minutes (or the equivalent) per day. This may result in muscle fatigue. It is recommended to use REVITIVE for 20-30 minutes per day.
Page 12
(negative (-) end) placed against the spring in each slot. Press the cover onto the back of the remote to close it. Before you use REVITIVE for the first time, read the Warnings and Cautions on pages 7-11. If in doubt, consult your doctor before using the product.
REVITIVE will be inclined, but will not rock during use. If you want to use the IsoRocker leave the IsoRocker in place on the bottom of REVITIVE, as shown. If you do not want to use the IsoRocker • Pull the IsoRocker bar on the bottom of REVITIVE.
Page 14
• Pull the IsoRocker bar back until it clicks open as shown. • To re-enable the IsoRocker, pull the IsoRocker bar and press into place on the bottom of REVITIVE. Locate the AC/DC power adapter. Plug the small end of the power cord into the opening on the side of the REVITIVE.
REVITIVE on. You will hear a beep and the control panel settings light up. To turn off REVITIVE at any time during operation, press the power button on the REVITIVE or remote control. 1718_IFU01_7244012.indd 15 27/03/2015 10:04...
Page 16
Instructions for use Set the time for the number of minutes you want to use REVITIVE. You can use the buttons on the control panel or remote control. Press the (+) button to increase the time. Press the (–) button to decrease the time.
Page 17
REVITIVE does not vibrate. The time control/display will start to count down in minutes as REVITIVE cycles through its program. When REVITIVE times out, the time display reads (00) and you will hear three beeps. The REVITIVE switches itself off automatically.
Instructions for use STEP 4: USING THE BODY PADS ( REVITIVE comes with two pairs of reusable (up to 20-30 applications) body pads that can be used to deliver electrical stimulation to the knees, shoulders, back or arms. Do NOT use the body pads on your head, face, neck or chest.
Page 19
Select the area you wish to apply electrical stimulation. If you wish to treat two areas at the same time, apply a pair of body pads to each area. Example placements are shown below: ✔ ✔ ✔ Upper Back Back of ✔...
Page 20
Instructions for use Make sure REVITIVE is switched off. If the control panel is still illuminated, press the power button and turn REVITIVE off. Attach the ends of the body pads to the body pad cords. If you are using both pairs of body pads, repeat this step for the remaining body pads.
Page 21
You will hear a beep and the control panel settings light up. To switch off the REVITIVE unit at any time during operation, simply press the power ON/OFF button. Set the time for the number of minutes you want to use REVITIVE.
Page 22
(–) button on the control panel or remote control. The time control/display will start to count down in minutes as REVITIVE cycles through its program. When REVITIVE times out, the time display reads (00) and you will hear three beeps.
Page 23
Place the body pads adhesive side down on either side of the body pad holders. Unplug the body pad cord(s) from the opening(s) on REVITIVE. You do not need to detach the body pads from the body pad cords. 1718_IFU01_7244012.indd 23...
Instructions for use STEP 5: USING THE FOOT PADS AND THE BODY PADS AT THE SAME TIME If you want to use body pads and the foot pads at the same time: • Follow the steps for Using the Body Pads •...
About the REVITIVE Remote Control The technology used in the remote control allows an emitted infrared signal to be sent to the REVITIVE unit. Infrared is a common and reliable technology within remote control devices. The signal is a binary-coded command that is unidirectional and low speed.
Problem Possible Cause Solution Not placing both bare feet on the Ensure that your feet are bare REVITIVE is on (lights illuminated on the foot pads at the same time. and each foot is placed on each LED display) but...
Page 27
Adaptor is plugged into properly. the device correctly. If still not working – contact your authorized dealer. REVITIVE is not REVITIVE IS NOT DESIGNED TO vibrating. VIBRATE. It is the muscles in your legs The ISOROCKER will only rock The IsoRocker is not "rocking".
Technical Specifications Name of product REVITIVE Model Weight 1.725Kg Ø360mm x 75mm (isorocker enabled) Dimensions Ø360mm x 100.5mm (isorocker disabled) Power Consumption Power Source: AC Adaptor – UL (Underwriters Laboratories) Safety Mark Input 100-240V, 50/60Hz, 0.18A. Output 5.0Vdc, 1.0A Output Specifications:...
Page 29
Net Charge @ 500Ω Foot: [0 - 0.006]mC Body: [0.001 - 0.002]mC Maximum Phase Charge @ 500 Ω Foot: 41µC Body: 15µC Maximum Current Density Foot: 0.023 mA/cm² Body: 0.082 mA/cm² Foot: 0.55 mW/cm² Body: 1.64 mW/cm² Maximum Power Density @ 500Ω Burst Mode: a.
Symbols Contraindications, Warnings and Cautions Make sure you understand these before using the REVITIVE Power Time Remaining Foot Pad Intensity Level Body Pad Intensity Level Center Positive Polarity Class II medical electrical equipment double insulated Type BF medical electrical equipment...
Lot no: ................manufacturer’s recommendations or All REVITIVE devices are individually tested where the fault has been caused by before leaving the factory. In the unlikely event power surges or damage caused in of any device proving to be faulty within 28 transit.
Need help?
Do you have a question about the IX and is the answer not in the manual?
Questions and answers
hi the sensitivity only goes up to 3