FAULT FINDING AND DIAGRAMS
7.6
Condensate pump Indicator lights
The condensate pump has indicator lights [1] which show operation
status or a fault condition.
Fig. 69 Condensate pump indicator lights
CONDENSATE PUMP - OPERATING LIGHTS AND FAULT CONDITIONS:
Ready for operation = Steady green light
Fault = Red light
Pump running = Flashing green light
Operating lamps
Cause
Green
Red
Off
Off
Mains supply not connected
Power failure
Flashing
Flashing
Dry-run
(possible air in pump)
On
Flashing
Pump blocked
On
On
Level exceeds alarm level
Off
Flashing
Pump blocked and
alarm level exceeded
48
Solution
Connect mains supply
Check mains and fuse/circuit breaker
Pump restarts automatically after one minute
Visually inspect the pump inlet and tank.
Remove or rinse out any dirt or foreign bodies
Discharge hose or non-return valve blocked
Possible kink in discharge hose
(clean or remove kink if applicable)
Visually inspect the pump inlet and tank.
Remove or rinse out any dirt or foreign bodies
ErP
- 6720818077 (2016/04)
Greenstar Highflow CDi
Need help?
Do you have a question about the Greenstar Highflow 440CDi ERP and is the answer not in the manual?