WARNING
Error
E0
E1
Symptom
Machine does not run.
8
Troubleshooting
Injury hazard!
Ignorance of proper machine handling is very dangerous.
Improper handling can lead to serious injuries.
For all service and repair work:
Make sure you observe the safety instructions and accident
prevention regulations.
Disconnect the unit's power supply from the mains electricity.
Only qualified electricians are permitted to work on electrical
modules.
Service and repair work should be carried out by authorised
technicians only.
8.1
Faults with diagnostic message
Symptom
The chamber lid does
not open after the
packaging procedure.
Chamber lid opens
during the sealing
process.
8.2
Faults without diagnostic message
Cause
• Machine is switched off.
• Mains plug is unplugged.
Cause
• Gas strut is un-
hooked.
• Ventilation valve
does not open.
• Machine control is
defective.
• The pressure dif-
ference between
the chamber and
the outside envi-
ronment is not
large enough be-
fore the sealing
process.
Solution
• Switch on the machine.
• Plug in the mains plug.
11.06.2014
Troubleshooting
Solution
• Hook in the gas strut,
for this open the
chamber lid more
than half way.
• Notify the service.
• Notify the service.
• Set the evacuation
time such that the
pressure display
shows a pressure dif-
ference of at least
0.35 bar before the
sealing process.