Advertisement

OURA-SERIES
www.heta.dk
www.heta.dk
GB
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Oura Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Heta Oura Series

  • Page 1 OURA-SERIES www.heta.dk www.heta.dk...
  • Page 2: Installation Instructions

    The Oura series have been appro- With your new stove you should have ved according to the EN 13240, NS received the following: 3058/3059 and 15a B-VG.
  • Page 3: Draft Conditions

    damper is fitted in the flue gas pipe, on or noise from the stove). there must always be at least 20 cm Draft conditions of free passage, even when the dam- Poor draft may result in smoke being per is in its “closed” position. If local emitted from the stove when the door regulations permit, two contained fire- is opened.
  • Page 4: First Firing

    Good draft occurs when: • The difference in temperature between the chimney and outdoor air is high. • The weather is fine. • The wind is blowing strongly. • The chimney is of the correct height: at least 4.00 m above the stove and free of the roof ridge.
  • Page 5: Chimney Fires

    Heating value in wood Lighting the stove You have to use about 2.4 kg normal To light the stove, use firelighters, wood to replace one litre of heating paraffin firelighter bags or small oil. All woods have almost the same pieces of wood.
  • Page 6 Fig. 3 call this combustion air). The stove provides excellent heating efficiency and the window is easy to maintain as the secondary air ‘flushes’ the surface of the glass. Note that the stove will, of course, blacken if the airflow is too low.
  • Page 7: Operational Problems

    OPERATIONAL PROBLEMS The chimney must be swept at least the flue gas pipe to regulate the draft. once a year, we recommend the use When cleaning the chimney, soot and of a NACS (national association of other deposits may come to fall on the chimney sweeps) registered chim- smoke turning plate.
  • Page 8 GUARANTEE The model Scan-Line 800 stoves are Damage resulting from incorrect use subjected to stringent quality con- Transport costs in connection with trol procedures both throughout the repairs carried out under guarantee produc-tion process and immediately Installation/disassembly in connection before delivery to the dealer. Therefo- with repairs carried out under guaran- re, the stoves are guaranteed against tee.
  • Page 9 Emptying the ash pan, fig. 4-7...
  • Page 10 Changing to back smoke outlet Fig. 8-15...
  • Page 11 Cleaning after sweeping the chimney andreplacing the stones. Fig 16-24...