Do not modify the unit. This unit should not be disas-
sembled or repaired by persons other than a qualified
technician.
Otherwise fire, electric shock or injury may result.
If repair is required, please consult the SHARP Service
Center.
Otherwise fire, electric shock or injury may result.
When any abnormality (e.g. a burning smell) is noticed,
turn the power off, unplug the unit and consult the SHARP
Service Center.
If the unit continues to be operated despite signs of abnormal-
ity, a breakdown, electric shock or fire may result.
Cautions for use
Do not operate this product with the power cord still wound
onto the cord clamps.
Otherwise, overheating or fire may result.
When the unit stops operating and the liquid crystal indicator shows a blinking "High-temperature"
mark: Check whether you use it in a situation or a place as follows. It does not indicate a breakdown.
When the compression machine (part of the refrigerating cycle) reaches an abnormal high tempera-
ture, the unit stops automatically for safety. During such circumstances, it is necessary to relocate
the unit, and to re-start operation again by pushing the Power Switch after a time interval (about 40
minutes). If the "High-temperature" indicator continues to blink, consult the shop where you pur-
chased the unit or an authorized dealer.
Check whether the DRY CLOTHES operation is set at "GENTLE" or if the dehumidifying operation is at "LOW", or if
the temperature of the airflow louver of the unit is at 35°C.
Check whether the air outlet or intake of the unit is obstructed with clothes etc.
Check whether the unit is operated in a location with inadequate ventilation such as a closet or a narrow space
between furniture.
Check whether the unit is operated in an improper place under direct sunshine, near heating sources or air outlet of hot
wind emerging from air conditioners or oil fan heaters.
Check whether the unit is operated in an area of 3.3 square meter or less.
When set to the CONTINUOUS DRY or DRY CLOTHES settings, the unit operates continuously re-
gardless of the ambient temperature or humidity. Since this may cause the room to be very warm
and dry, do not operate the unit in either of these modes for an extended period of time when people
are present in the room.
Warning
AUTO DRY
ROOM DRY
CONTINUOUS
DRY
CLEAN AIR
Please consult the SHARP service
center for repair if needed.
Blinking
FAST
STANDARD
GENTLE
5