Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Westward battery chargers are mobile oor units designed to deliver maximum
starting power. They charge up to 60 amperes (maximum) on 6 or 12 volt batteries
(1JYT9A max 40 amps).
Chargers are equipped with a timer control, charging voltage and rate selector,
ammeter and automatic reset circuit breaker.
Figure 1
Speci cations
Power Supply
Requirements
Primary AC
input@ rated
12 V output
Max Continuos
Charge Output
Start Output
@7.2V
Medium charge
output
Motorcycle or
nishing charging
Average
Charging Time
Primary AC
input@start
Form 5S4079
Printed in Taiwan
05/10 JL06
1JYT9A
1JYU1A
120 VAC,
120 VAC,
60 Hz
60 Hz
8.5 Amps
12.0 Amps
@120V
@120V
60 Hz
60 Hz
40 Amps
60 Amps
@6/12V
@6/12V
200 Amps
250 Amps
@7.2V
@7.2V
130 Amps
185 Amps
@6V
@6V
20 Amps
40 Amps
@12V
@12V
2 Amps
2 Amps
@12V
@12V
3/4 to 1/2 hr
1/2 to 1 hr
29 Amps
43 Amps
1JYT9A, 1JYU1A, 1JYU2A and 1JYU3A
Important Safety
Instructions
READ THESE FIRST
1. SAVE THESE INSTRUCTIONS.
This manual contains important
safety and operating instructions.
2. Do not expose charger to rain or
snow.
3. Use of an attachment not
recommended or sold by the
manufacturer may result in a risk of
re, electric shock, or injury to
persons.
4. To reduce risk of damage to electric
plug and cord, pull by plug rather
than cord when disconnecting
charger.
5. An extension cord should not be
used unless absolutely necessary.
1JYU2A
120 VAC,
60 Hz
12.0 Amps
@120V
60 Hz
60 Amps
@6/12V
250 Amps
@7.2V
185 Amps
@6V
0-60 Amps
@6/12V
0-3 Amps
@6/12V
1/2 to 1 hr
58 Amps
E
N
G
L
S
H
1JYU3A
120 VAC,
60 Hz
12.0 Amps
@120V
60 Hz
60 Amps
30 Amps
@6/12V
@24V
225 Amps
@7.2V
160 Amps
@6V
40 Amps
@12V
Not
Applicable
1/2 to 1 hr
35 Amps
I
Need help?
Do you have a question about the 1JYT9A and is the answer not in the manual?
Questions and answers
Need to replace the cooling fan
To replace the cooling fan for Westward part number 1JYT9A, follow these steps using the listed parts:
1. Disconnect power and ensure the unit is off.
2. Locate and remove the Fan Blade (part TT316014666G).
3. Remove the Fan Mounting Bracket (part TT412590666G).
4. Disconnect and remove the Fan Motor (part TT216041666G).
5. Install the new Fan Motor, secure it using the Fan Mounting Bracket.
6. Attach the new Fan Blade to the motor.
7. Ensure all parts are securely fastened and reconnect power.
Make sure the fan rotates freely before turning the unit on.