Visualisation Of Defects - Bonnet EQUATOR Instructions For Use Manual

Combi oven
Hide thumbs Also See for EQUATOR:
Table of Contents

Advertisement

2.2 VISUALISATION OF DEFECTS

Probe defects
- E40: 1 or 2 (out of 3) core probe feelers cut.
- E41: 1 or 2 (out of 3) core probe feelers short-circuited.
- E61: Ambient probe short-circuited.
- E62: Ambient probe cut.
- E63: Missing or cut core probe.
- E64: Short-circuited core probe.
Other defects
- E42: Electronic controls internal temperature exceeded.
- E43: Saturated steam injection activated for more than 30 secs in steam mode.
(Condenser nozzle encrusted, condenser fed with hot water or insufficient flow of water).
- E46: Communication fault between the relay and facia cards.
- E51: Ambient temperature set to 0.
- E52: Time or core temperature set to 0.
- E53: Ventilation not functional.
- E67: Gas safety inlet activated.
- E68: Temperature of oven capacity at + 290°C.
Page 10
Switch for adjustment of set temperature
Each defect is shown on the display indicating the set temperature.
The defects E50 to E99 stop cooking or prevent the start of cooking
and are announced by a "beep".
BONNET GRANDE CUISINE
Registered Office:
Rue des Frères Lumière - Z.I Mitry Compans
F-77292 MITRY MORY Cedex
3BE390758NU – 12/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EQUATOR and is the answer not in the manual?

Questions and answers

Richard Tilley
February 13, 2025

We have a bonnet equator cooker. The black handle has fallen off ,how do you remove the back of the door to screw the bolt back into the handle

User image 67ae17788868b

Subscribe to Our Youtube Channel

Table of Contents

Save PDF