Step 1 –
Unpacking
1)
With two people lift
2)
Using the four
machine straight out of
adjustable rubber feet
corrugated box and
level vacuum machine
place machine on a
on the secure table.
secure table.
CAUTION:
When unpacking
DO NOT tilt
machine.
Step 2 –
Adding Oil
1)
Remove the machine
2)
Carefully remove the
back cover using the
upper oil fill plug using
supplied hex wrench.
the supplied hex wrench
or pliers.
Add supplied non-
detergent pump oil until
it reaches the middle
of the sight glass and
replace the upper oil
fill plug tightly.
3)
Remove white
4)
Remove all packing
protective coating
material.
adhered to the
stainless steel.
CAUTION:
DO NOT remove brown
Teflon tape from sealing
bar(s).
Example pictures show the MVS 31XP. Your packaging may slightly differ.
3)
Plug female end of AC
4)
Turn power switch to
power cord directly into
the ON position and cycle
machine and the other
machine a minimum of
end into an AC outlet.
three times.
IMPORTANT:
Be sure to calibrate
machine before
operating.
Example pictures show the MVS 31XP. Your machine and tools may slightly differ.
Step 3 –
Calibrating
LED
1)
Open lid, confirm that main power switch is in the OFF position.
Display
2)
Simultaneously hold down
3)
Close lid, machine will automatically start within 15 seconds.
4)
As the display increments up, note the three digit number it levels off at.
5)
Depress
to set, open lid and turn power switch back to the OFF position.
S
6)
Repeat procedure except this time depress
noted number from step 4. Machine is now calibrated to its environment.
LCD
1)
Open lid, turn power switch to ON position, after 30 seconds machine will display PROGRAM.
Display
2)
Hold
down for 6 seconds, machine will display CALIBRATE.
3)
Press
10 times until CALIBRATE is highlighted, close lid to start.
4)
Display will increment down and eventually stop decreasing.
5)
Depress
and open lid, machine will return to operation after 6 seconds.
6)
SAVING DATA appears on the display. Machine is now calibrated to its environment.
Step 4 –
Programming
LED Display
1)
Open lid, turn main power switch to ON, wait for P1 to display. Press
2)
VACUUM % – Use
to select vacuum % (at 99.9% machine offers extra vacuum time). Press
3)
EXTRA VACUUM TIME – Use
to select value (up to 30 seconds). Press
4)
INERT GAS % [OPTIONAL] – Use
to select % of gas injection. Press
5)
SEALING TIME – Use
to select seconds of sealing time. Press
LCD Display
1)
Open lid, turn power switch to ON, wait for program P01 to display. Press
2)
SEALING TIME – Use
to select seconds of sealing time. Press
3)
VACUUM % – Use
to select vacuum % (at 100% machine offers extra vacuum time). Press
4)
VACUUM DISPLAY – Use
to select display in % or millibar. Press
5)
EXTRA VACUUM TIME – Use
to select value (up to 45 seconds). Press
6)
INERT GAS % [OPTIONAL] – Use
to select % of gas injection. Press
, turn main power switch ON, release when CAL appears.
when the display reaches 1 digit below the
S
Refer to operational manual for detailed programming instructions.
S
to open a program and move forward.
to move forward.
S
to move forward.
S
to move forward.
S
to lock in the data.
S
to open a program and move forward.
to move forward.
to move forward.
to move forward.
to move forward.
twice to return to the main menu.