Advertisement

Available languages

Available languages

HIGH - END ELECTRONICS
BORN IN ITALY
Unico
Secondo

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Unico Secondo and is the answer not in the manual?

Questions and answers

Summary of Contents for Unison Research Unico Secondo

  • Page 1 HIGH - END ELECTRONICS BORN IN ITALY Unico Secondo...
  • Page 2: Manuale D'istruzioni

    Unison Research Unico Secondo MANUALE D’ISTRUZIONI Ci congratuliamo e Vi ringraziamo per la fiducia accordataci per aver scelto un amplificatore Unison Research - A.R.I.A. Advanced Research In Audio S.r.l.. Vi raccomandiamo di leggere attentamente queste poche righe prima di installare l’apparecchio.
  • Page 3: Installazione

    Unison Research Unico Secondo 2. INSTALLAZIONE L’amplificatore deve sempre essere sistemato in un posto sicuro, fuori della portata dei bambini ed è necessario assicurargli un’adeguata ventilazione ed evitare di esporlo ad elevate temperature ed umidità. Le valvole sono già posizionate all’interno dell’apparecchio.
  • Page 4: Funzionamento

    6. FUNZIONE DEI LED L’Unico Secondo è provvisto di due led che forniscono all’utilizzatore importanti informazioni sullo stato operativo dell’amplificatore; indichiamo con LED1 il led in prossimità della manopola del selettore degli ingressi e con LED2 quello vicino al potenziometro.
  • Page 5 Unison Research Unico Secondo Nel caso in cui si verifichi l’intervento della protezione termica, controllate che l’apparecchio sia adeguatamente ventilato. In caso di mancanza anche rapida di energia elettrica, l’apparecchio riparte con la preaccensione. 7. FUSIBILI Internamente all’apparecchio vi sono sei fusibili:...
  • Page 6 Unison Research Unico Secondo 9. LA SCHEDA PHONO Nell’ Unico Secondo può essere installata una scheda phono dedicata, che si compone di due stadi attivi per canale, con la sezione RIAA di tipo attivo per le basse frequenze, e passivo per le alte frequenze. Con tale soluzione, frutto di lunghe prove e test di ascolto, le note basse risultano profonde e smorzate, e le alte frequenze sono limpide e non “graffianti”.
  • Page 7 Unison Research Unico Secondo 10. PRECAUZIONI SICUREZZA MANUTENZIONE Non far funzionare l’amplificatore con il fondo o la calotta rimossi! L’unità presenta al suo interno alte tensioni che possono essere causa di danni anche gravi. Non aprire l’apparecchio! Nessun ulteriore intervento oltre a quelli descritti in questo manuale deve essere effettuato dall’utilizzatore.
  • Page 8: Caratteristiche Tecniche

    Unison Research Unico Secondo 11. CARATTERISTICHE TECNICHE Potenza d’uscita: >100W continui su 8 >200W continui su 4 Stadio di uscita: doppio POWER MOSFET a simmetria complementare Valvole: 2 x ECC83 (12AX7) Risposta in frequenza: flat@10Hz / -0.5dB@100 kHz Impedenza d’ingresso: 50 kOhm / 47 pF Fattore di smorzamento: >50...
  • Page 9 Unison Research Unico Secondo INDICE : Introduzione pag. 2 Sballaggio pag. 2 Installazione pag. 3 Collegamento degli ingressi e delle uscite di segnale pag. 3 Collegamento alla rete pag. 3 Funzionamento pag. 3 Funzione del led pag. 4 Fusibili interni pag.
  • Page 10 Please take a little time to read the following notes. They will help you to get the best from your new Unison Research Unico Secondo. Every Unison Research product is the fruit of great experience in electronic design as well as a profound knowledge of vacuum tubes and how to get the best performance from them.
  • Page 11: Installation

    = -) Loudspeaker connection - Bi-Wiring The Unico Secondo is equipped with twin pairs of loudspeaker output terminals. If your loudspeakers are equipped with twin pairs of input terminals this will enable you to connect the amplifier to the loudspeakers using the bi-wiring method.
  • Page 12: Operation

    Always replace fuses with new ones of the same type and value ! OPERATION Warning! Switch on the Unico Secondo only after all the input and output connections (including loudspeaker connections) have been made and checked !
  • Page 13: Internal Fuses

    If there is a temporary loss of mains electricity (even of very short duration) the amplifier will restart in automatic start-up mode. INTERNAL FUSES Inside the Unico Secondo there are six fuses.: = 6,3AT / 250V = 6,3AT / 250V...
  • Page 14 THE PHONO BOARD Inside the Unico Secondo there is a dedicated phono board. This consists of two active gain stages for each channel and an RIAA equalisation stage which is active for the low frequencies and passive for the high frequencies.
  • Page 15 PRECAUTIONS Never operate the amplifier with either the bottom or top covers removed. High voltages are present within the Unico Secondo, which could cause severe electric shock. Do not open the amplifier ! There are no user adjustments inside, and none other than those described in this manual.
  • Page 16 Unison Research Unico Secondo Use a soft dry cloth. Do not use solvents or alcohol-based detergents. Do not rub hard on the screen-printed legends on the top cover. Never operate the amplifier when covered! Adequate ventilation is essential at all times!
  • Page 17: Technical Specifications

    Unison Research Unico Secondo TECHNICAL SPECIFICATIONS Output power: >100W continuous 8 >180W continuous 4 Output stage: symmetrical complementary double POWER MOSFET Valves: 2 x ECC83 (12AX7) Frequency response: flat@10Hz / -0.5dB@100 kHz Input impedance: 50 kOhm / 47 pF Damping factor: >50...
  • Page 18: Declaration Of Conformity

    Unison Research Unico Secondo DECLARATION OF CONFORMITY Unico Secondo Amplifier Manufacturer A.R.I.A. Advanced Research In Audio srl Via E. Barone, 4 31030 Dosson di Casier ( TV ) ITALY Statement of Conformity Based on test results using appropriate standards, the product is in conformity with Electromagnetic...
  • Page 19 Unison Research Unico Secondo INDEX : Introduction pag. 10 Unpacking pag. 10 Installation pag. 11 Connecting Inputs and outputs pag. 11 Connection to the mains pag. 11 Operation pag. 12 Function of the LEDs pag. 12 Internal fuses pag. 13 Remote control pag.
  • Page 20 Unison Research Unico Secondo INFORMATIVA AGLI UTENTI Ai sensi dell’art. 13 de Decreto Legislativo 25 luglio 2005, n.151 “Attuazione delle Direttive 2002/95/CE e 2003/108/CE, relative alla riduzione dell’uso di sostanze pericolose nelle apparecchiature elettroniche, nonché alla smaltimento dei rifiuti” Il simbolo del cassonetto barrato riportato sull’apparecchiature indica che il prodotto alla fine della propria vita utile deve essere raccolto separatamente dagli altri rifiuti.
  • Page 21 Unison Research Unico Secondo Možnost posebnih zbiranj za proizvode namenjene recikliranju, obdelavi ali uni enju, je potrebna za prepre itev negativnih u inkov na zdravje in okolje. Hkrati onemogo a ponovno uporabo in/ali nepravilno oz. nestrokovno recikliranje materialov, uporabljenih za take proizvode.

Table of Contents

Save PDF