AP SERIES
970-292 Revised 5-12
P SERIES

Table of Contents

Model Nomenclature ..................................................................................................................1
Initial Inspection............................................................................................................................2
General Description .....................................................................................................................2
Moving and Storage ....................................................................................................................2
Safety Considerations .................................................................................................................2
Location............................................................................................................................................2
Installation.......................................................................................................................................2
Condensate Drain.........................................................................................................................3
Duct System....................................................................................................................................3
Piping ................................................................................................................................................3
Electrical ...........................................................................................................................................4
Thermostat Connections ...........................................................................................................4
Safety Devices & the UPM Controller....................................................................................5
Electric Heater Package Option...............................................................................................6
Sequence of Operation Single Stage Units.........................................................................7
Sequence of Operation Two-Stage Units ............................................................................7
Well Water Systems .....................................................................................................................7
Installation of Pressure Regulating Valves ..........................................................................7
Cooling Tower / Boiler Application........................................................................................7
Earth Coupled Systems...............................................................................................................8
System Checkout ..........................................................................................................................8
Unit Start-Up...................................................................................................................................8
Maintenance...................................................................................................................................8
Wiring Diagrams ...........................................................................................................................9
Trouble Shooting .......................................................................................................................13
Unit Check Out............................................................................................................................14
Operating Pressures & Temperatures.................................................................................15
MODEL NOMENCLATURE
A P
0 4 9 - 1
SERIES:
AP-AQUARIUS II
NOMINAL CAPACITY:
VOLTAGE DESIGNATION:
1 - 208/1/60 & 230/1/60
CABINET CONFIGURATION:
VT - VERTICAL
HZ - HORIZONTAL
CF - COUNTERFLOW
HEAT EXCHANGER MATERIAL:
C - COPPER
N - CUPRO-NICKEL
V T
C - F
L
T
SUPPLY AIR LOCATION:
T - TOP (VT ONLY)
E - END BLOW (HZ ONLY)
B - BOTTOM (CF ONLY)
RETURN AIR LOCATION:
L - LEFT
R - RIGHT
B - BACK
F - FRONT
WATER CONNECTION
LOCATION:
F - FRONT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AP025 and is the answer not in the manual?

Questions and answers

Summary of Contents for FHP AP025

  • Page 1: Table Of Contents

    AP SERIES P SERIES Table of Contents Model Nomenclature ........................1 Initial Inspection..........................2 General Description ........................2 Moving and Storage ........................2 Safety Considerations .........................2 Location............................2 Installation............................2 Condensate Drain.........................3 Duct System............................3 Piping ..............................3 Electrical ............................4 Thermostat Connections ......................4 Safety Devices & the UPM Controller..................5 Electric Heater Package Option....................6 Sequence of Operation Single Stage Units.................7 Sequence of Operation Two-Stage Units ................7...
  • Page 2: Initial Inspection

    AP SERIES INITIAL INSPECTION: LOCATION: Be certain to inspect all cartons or crates on each unit as Locate the unit in an indoor area that allows easy removal received at the job site before signing the freight bill. Verify of the filter and access panels, and has enough room for that all items have been received and that there are no service personnel to perform maintenance or repair.
  • Page 3: Condensate Drain

    Refer to tape sealer should be used when connecting water piping the FHP individual data specification sheet for physical connections to the units to insure against leaks and dimensions of the collar and flange.
  • Page 4: Electrical

    AP SERIES connections. Flexible hoses should be used between the NOTE: Units supplied with internal electric heat require unit and the rigid system to avoid possible vibration. Ball two (2) separate power supplies: one for the unit valves should be installed in the supply and return lines for compressor and one for the electric heater elements, unit isolation and unit water flow balancing.
  • Page 5: Safety Devices & The Upm Controller

    (C) side of the transformer, the electric heaters are installed. Doing so may cause the unit must be provided with a malfunction relay (FHP option heaters to cycle on their thermal overload switches, # 660-006) to properly energize the light. The relay coil will potentially shortening the life of the switches.
  • Page 6 AP SERIES produced and a fault code is detected by a remote device indicating the fault. See L.E.D. Fault Indication below for blink code explanations. The remote device must have a malfunction detection capability when the UPM board is set to “PULSE”. TEST DIP SWITCH •...
  • Page 7 UNIT OPTIONS HOT GAS REHEAT (HGR) FHP recommends the following guidelines for wiring between a thermostat and the unit: 18 GA up to 60 Hot gas reheat allows the user to not only control space foot, 16 GA up to 100 ft and 14 GA up to 140 ft.
  • Page 8 AP SERIES UPM Sequence of Operation (SOO) Flow Chart Y1=1 Power/Switchs/Sensor Status Check 18VAC > Lockout Can Be Set To 4 Via Dip Switch Blink Code On Status LED Soft Lockout HPC = 1 COUNT = 2 Record Alarm Start Counter (If Applicable) TIME >...
  • Page 9: Electric Heater Package Option

    30 seconds. (Figure #9) AQUARIUS II HEATER HEATER CIRCUIT MODEL MODEL AMPS FUSE 208V 240V 208V 240V 208V 240V AP025 thru 035 HP050-1XS 17.3 20.0 L1/L2 27.1 30.4 AP049 thru 071 HP050-1XM 17.3 20.0 L1/L2 27.1 30.4 AP025 thru 035 HP075-1XS 23.6...
  • Page 10: Well Water Systems

    • Verify that the low voltage wiring between the thermostat and the unit is correct. In the cooling mode, heat is rejected from the FHP unit into the water loop. A cooling tower provides evaporative • Verify that the water piping is complete and correct.
  • Page 11: Unit Start-Up

    AP SERIES secured in place. MAINTENANCE: Filter changes or cleanings are required at regular intervals. The time period between filter changes will UNIT START-UP: depend upon type of environment the equipment is used in. In a single family home, that is not under Set the thermostat to the highest setting.
  • Page 12 AP SERIES 970-292 Revised 5-12...
  • Page 13 AP SERIES AP SERIES 970-292 Revised 5-12...
  • Page 14 AP SERIES EARTH COUPLED APPLICATION LINE VOLTAGE DISCONNECT (UNIT) FLEX DUCT CONNECTION LOW VOLTAGE CONTROL CONNECTION LINE VOLTAGE CONNECTION (UNIT) P/T PORTS VIBRATION PAD CONDENSATE DRAIN GROUND LOOP CONNECTION KIT (555-000,001) GROUND LOOP PUMPING PACKAGE (GL001-1 or 002-1) POLYETHELENE WITH INSULATION LINE VOLTAGE DISCONNECT (ELECTRIC HEATER) NOTE: SEE FIGURE #3 FOR CONDENSATE DRAIN CONNECTION (Figure #12)
  • Page 15 AP SERIES 970-292 Revised 5-12...
  • Page 16 AP SERIES (Figure #13) 970-292 Revised 5-12...
  • Page 17: Trouble Shooting

    AP SERIES TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE CHECKS AND CORRECTIONS Power supply off Apply power, close disconnect ENTIRE UNIT DOES NOT RUN Blown fuse Replace fuse or reset circuit breaker. Check for correct fuses. Voltage supply low If voltage is below minimum voltage specified on unit data plate, contact local power company. Thermostat Set the fan to "ON", the fan should run.
  • Page 18: Unit Check Out

    AP SERIES UNIT CHECK-OUT SHEET Customer Data Customer Name ______________________________________________ Date _________________________________ Address _____________________________________________________ _____________________________________________________ Phone ______________________________________________________ Unit Number __________________________ Unit Nameplate Data Unit Make _________________________________________ Model Number_____________________________________ Serial Number_________________________________ Refrigerant Charge (oz) ________ Compressor: RLA _____________ LRA ______________ Blower Motor: FLA (or NPA) ____________ HP_______________ Maximum Fuse Size (Amps) ___________ Minimum Circuit Ampacity (Amps) ______________...
  • Page 19: Operating Pressures & Temperatures

    14-17 18-20 98-122 291-356 20-23 50˚ 124-151 204-250 19-22 110-130 298-364 21-24 134-163 249-305 13-16 17-20 112-136 304-372 8-10 22-26 AP025 60˚ 128-156 233-287 18-21 117-143 312-381 23-28 Part 138-168 281-341 13-16 17-19 124-152 318-389 9-11 24-29 Load 70˚ 133-161...
  • Page 20 AP SERIES Operating Pressures & Temperatures Environmentally Safe R-410A Refrigerant OPERATING DATA COOLING HEATING ENTERING WATER SUCTION DISCHARGE WATER SUCTION DISCHARGE WATER MODEL WATER FLOW PRESSURE PRESSURE TEMP TEMP PRESSURE PRESSURE TEMP TEMP TEMP. ˚F PSIG PSIG RISE ˚F DROP ˚F PSIG PSIG DROP ˚F...
  • Page 21 AP SERIES Operating Pressures & Temperatures Environmentally Safe R-410A Refrigerant OPERATING DATA COOLING HEATING ENTERING WATER SUCTION DISCHARGE WATER SUCTION DISCHARGE WATER MODEL WATER FLOW PRESSURE PRESSURE TEMP TEMP PRESSURE PRESSURE TEMP TEMP TEMP. ˚F PSIG PSIG RISE ˚F DROP˚ F PSIG PSIG DROP ˚F...
  • Page 22 AP SERIES Operating Pressures & Temperatures Environmentally Safe R-410A Refrigerant OPERATING DATA COOLING HEATING ENTERING WATER SUCTION DISCHARGE WATER SUCTION DISCHARGE WATER MODEL WATER FLOW PRESSURE PRESSURE TEMP TEMP PRESSURE PRESSURE TEMP TEMP TEMP. ˚F PSIG PSIG RISE ˚F DROP ˚F PSIG PSIG DROP ˚F...
  • Page 23 AP SERIES Notes 970-292 Revised 5-12...
  • Page 24 601 N.W. 65th Court, Ft. Lauderdale, FL 33309 Phone: 954-776-5471 | Fax: 954-776-5529 www.boschtaxcredit.com | www.fhp-mfg.com 970-292 Revised 5-12...

This manual is also suitable for:

Ap035Ap049Ap061Ap071

Table of Contents